This manual provides detailed instructions for the installation, operation, and maintenance of the Planet IGS-4215-8P2T2S Industrial Managed Switch. This device is designed for robust industrial networking environments, offering high-speed data transmission and Power over Ethernet (PoE+) capabilities. Please read this manual thoroughly before using the product to ensure proper setup and optimal performance.

2. Koniec produktuview

2.1 Główne cechy

  • Eight 10/100/1000BASE-T Gigabit Ethernet RJ45 ports with IEEE 802.3at/af PoE+ Injector function (Ports 1 to 8).
  • Two 10/100/1000BASE-T Gigabit Ethernet RJ45 ports (Ports 9 to 10).
  • Two 100/1000BASE-X mini-GBIC/SFP slots for SFP type auto detection (Ports 11 to 12).
  • One RJ45 console interface for basic management and setup.
  • Complies with IEEE 802.3at Power over Ethernet Plus, end-span PSE.
  • Backward compatible with IEEE 802.3af Power over Ethernet.
  • Supports up to 8 ports of IEEE 802.3af/802.3at devices powered.
  • 240-watt PoE budget.
  • Supports PoE power up to 36 watts for each PoE port.
  • PoE management features including total PoE power budget control and per-port PoE function enable/disable.

2.2 Komponenty fizyczne

The IGS-4215-8P2T2S switch features a robust industrial design with various ports and indicators for easy deployment and monitoring.

Planet IGS-4215-8P2T2S Industrial Managed Switch, angled view

Rysunek 2.1: Kątowy view of the Planet IGS-4215-8P2T2S Industrial Managed Switch, showing the front panel with ports and indicators, and the side heat sink.

Front panel of Planet IGS-4215-8P2T2S switch

Rysunek 2.2: Front panel of the IGS-4215-8P2T2S switch. This view highlights the eight PoE+ RJ45 ports (1-8), two standard RJ45 ports (9-10), two SFP slots (11-12), console port, reset button, and LED indicators for power, alarm, link/activity, and PoE usage.

  • PoE+ RJ45 Ports (1-8): Connect PoE-powered devices (PDs) such as IP cameras, VoIP phones, or wireless access points.
  • Standard RJ45 Ports (9-10): Connect non-PoE network devices or uplink to other switches/routers.
  • Gniazda SFP (11-12): Insert 100/1000BASE-X SFP transceivers for fiber optic connections, extending network reach.
  • Port konsoli: RJ45 port for command-line interface (CLI) management.
  • Przycisk resetowania: Służy do przywracania ustawień fabrycznych.
  • Wskaźniki LED: Provide visual status for power, alarm, link/activity, and PoE usage.
Rear panel of Planet IGS-4215-8P2T2S switch

Rysunek 2.3: Rear panel of the IGS-4215-8P2T2S switch, showing the DC power input terminal block and fault alarm loading connections. The power input supports 48-54V DC, 6A max.

  • Wejście zasilania prądem stałym: Terminal block for connecting 48-54V DC power supply.
  • Fault Alarm Loading: Terminal block for connecting external alarm systems.

3. Konfiguracja

3.1 Rozpakowanie

Carefully unpack the switch and verify that all components are present and undamaged. Retain the packaging materials for future transport or storage.

3.2 Montaż

The IGS-4215-8P2T2S is designed for industrial environments and typically supports DIN-rail or wall mounting. Refer to the specific mounting kit instructions for secure installation in your desired location. Ensure adequate ventilation around the device.

3.3 Połączenie zasilania

  1. Ensure the power source is off before connecting.
  2. Connect a 48-54V DC power supply to the terminal block on the rear panel (refer to Figure 2.3). Observe correct polarity (V1+, V1-, V2+, V2-).
  3. Secure the wires firmly within the terminal block.
  4. Once all network connections are made, apply power to the switch.

3.4 Połączenia sieciowe

  • Porty RJ45: Connect standard Ethernet cables (Cat5e or higher) from your network devices to the RJ45 ports (1-10). For PoE-powered devices, use ports 1-8.
  • Sloty SFP: Insert compatible 100/1000BASE-X SFP transceivers into slots 11-12, then connect fiber optic cables.
  • Port konsoli: For initial configuration or advanced management, connect a console cable from your computer to the RJ45 console port.

4. Instrukcja obsługi

4.1 Power On and Initial Status

Upon applying power, the switch will initiate its boot sequence. Observe the power LED for a steady green indication. Link/Activity LEDs for connected ports will illuminate when a valid network connection is established and blink during data transmission. PoE-in-Use LEDs will indicate when power is being supplied to a connected PD.

4.2 Power over Ethernet (PoE+) Functionality

The IGS-4215-8P2T2S supports IEEE 802.3at/af PoE+ on ports 1-8, providing up to 36 watts per port with a total budget of 240 watts. The switch automatically detects and powers compatible PDs. The PoE Usage LEDs provide a visual indication of the total power consumption.

4.3 Zarządzanie

As a managed switch, the IGS-4215-8P2T2S offers various management options:

  • WebZarządzanie oparte na: Uzyskaj dostęp do graficznego interfejsu użytkownika (GUI) przełącznika za pomocą web browser for easy configuration and monitoring. Refer to the full user manual for default IP address and login credentials.
  • Interfejs wiersza poleceń (CLI): Use the console port for text-based configuration, ideal for advanced users and scripting.
  • SNMP: Zintegruj przełącznik z systemami zarządzania siecią, używając protokołu SNMP w celu scentralizowanego monitorowania.

5. Konserwacja

5.1 Czyszczenie

Periodically clean the exterior of the switch with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and debris to prevent overheating.

5.2 aktualizacji oprogramowania sprzętowego

Regularnie sprawdzaj producenta website for firmware updates. Keeping the firmware up-to-date ensures optimal performance, security, and access to new features. Follow the provided instructions carefully when performing firmware upgrades.

5.3 Względy środowiskowe

Ensure the switch operates within its specified temperature and humidity ranges. Avoid exposing the device to direct sunlight, excessive heat, moisture, or strong electromagnetic fields.

6. Rozwiązywanie Problemów

6.1 Brak zasilania

  • Verify the DC power supply is correctly connected and providing the specified voltagi (prąd stały 48-54 V).
  • Check the power source and ensure it is active.
  • Confirm the power LED on the switch is illuminated.

6.2 No Link/Activity

  • Ensure network cables are securely connected to both the switch and the connected device.
  • Verify the cable type and length are appropriate for the connection speed.
  • Sprawdź status podłączonego urządzenia.
  • Spróbuj użyć innego portu lub kabla.

6.3 PoE nie działa

  • Ensure the connected device is a PoE-powered device (PD) and complies with IEEE 802.3af/at standards.
  • Verify the PD's power requirements do not exceed 36 watts per port or the total 240-watt budget.
  • Check the PoE-in-Use LED for the specific port.
  • Access the switch's management interface to check PoE settings and ensure the port's PoE function is enabled.

6.4 Przywracanie ustawień fabrycznych

If issues persist or configuration problems arise, a factory reset can restore the switch to its default settings. Locate the reset button on the front panel (refer to Figure 2.2) and press and hold it for approximately 5-10 seconds until the system LEDs indicate a reset sequence.

7. Specyfikacje

FunkcjaOpis
ModelIGS-4215-8P2T2S
Porty Ethernet8x 10/100/1000BASE-T RJ45 (PoE+), 2x 10/100/1000BASE-T RJ45
Sloty SFP2x 100/1000BASE-X mini-GBIC/SFP
Interfejs konsoli1x RJ45
Standard PoEIEEE 802.3at/af
Moc wyjściowa PoEUp to 36W per port (Ports 1-8)
Całkowity budżet PoE240 watów
Wejście zasilania DC48-54V DC, 6A max
Waga przedmiotu5 funta
Zawarte komponentyPrzełącznik zarządzany

8. Gwarancja i wsparcie

This Planet IGS-4215-8P2T2S Industrial Managed Switch comes with a standard manufacturer's warranty. For specific warranty terms, duration, and conditions, please refer to the warranty card included with your product or visit the official Planet Technology website. For technical support, troubleshooting assistance, or service inquiries, please contact Planet Technology customer support directly. Keep your purchase receipt and product serial number readily available when seeking support.

Powiązane dokumenty - IGS-4215-8P2T2S

Przedview Instrukcja szybkiej instalacji przemysłowego przełącznika Ethernet zarządzanego PLANET serii IGS-6325
Niniejsza skrócona instrukcja instalacji zawiera podstawowe informacje dotyczące instalacji i konfiguracji przemysłowych zarządzalnych przełączników Ethernet PLANET IGS-6325 montowanych na szynie DIN. Obejmuje ona zawartość opakowania, wymagania systemowe, okablowanie zasilania, zaciski i… web konfiguracja zarządzania, konfiguracja IP i zasoby wsparcia klienta.
Przedview Instrukcja obsługi przełącznika Ethernet przemysłowego PLANET IGS-801M
Zapoznaj się z instrukcją obsługi przemysłowego przełącznika Ethernet PLANET IGS-801M. W tym podręczniku szczegółowo opisano funkcje, instalację, konfigurację i zarządzanie 8-portowym przemysłowym przełącznikiem 10/100/1000 Mb/s, zapewniając niezawodne rozwiązania sieciowe.
Przedview PLANET WGS-4215 Series Industrial Managed Gigabit Ethernet Switch Quick Installation Guide
Quick installation guide for the PLANET WGS-4215-8P2X and WGS-4215-8P2XV Industrial Wall-mount Managed Gigabit Ethernet Switches. Covers package contents, requirements, power wiring, hardware installation, web oraz logowanie, konfiguracja i rozwiązywanie problemów SSH.
Przedview Instrukcja szybkiej instalacji przemysłowego przełącznika Ethernet zarządzanego PLANET serii IGS-6325
Krótki przewodnik instalacji przemysłowych zarządzalnych przełączników Ethernet PLANET IGS-6325-4T2X, IGS-6325-4UP2X i IGS-6325-5X1T, obejmujący zawartość opakowania, wymagania, okablowanie zasilania, konfigurację terminala, web zarządzanie i przywracanie domyślnej konfiguracji.
Przedview PLANET IGS-5227X-4P2T Industrial Managed PoE+ Switch Quick Installation Guide
A concise guide to installing and configuring the PLANET IGS-5227X-4P2T, an IP67-rated industrial managed PoE+ Ethernet switch with 4x 10/100/1000T PoE ports and 2x 10/100/1000T ports.
Przedview Krótki przewodnik instalacji przemysłowych przełączników zarządzalnych PLANET IGS-6325-4T2X/IGS-6325-5X1T
Niniejszy przewodnik zawiera niezbędne informacje dotyczące szybkiej instalacji przemysłowych przełączników Ethernet L3 Multi-Gigabit/10Gigabit firmy PLANET, modeli IGS-6325-4T2X i IGS-6325-5X1T. Obejmuje on zawartość opakowania, wymagania systemowe, okablowanie zasilania, konfigurację terminali i… web kierownictwo.