This manual provides detailed instructions for the installation, operation, and maintenance of the Trane KIT18110 OEM Upgraded Furnace Control Board Kit. This kit is designed as an American Standard / Trane OEM component for furnace units built after 1995. It includes the control board (CNT07541), ignitor, wire harness, and bracket.

Ważna uwaga: For downflow units built in 1999 and earlier, use KIT18109. For all other units built after 1995, use KIT18110.

Informacje dotyczące bezpieczeństwa

OSTRZEŻENIE: Installation and servicing of heating, ventilation, and air conditioning (HVAC) equipment can be hazardous due to system pressure, electrical components, and equipment location. Only trained and qualified service personnel should install, repair, or service HVAC equipment.

Zawartość opakowania

The Trane KIT18110 kit typically includes the following components:

Trane KIT18110 Furnace Control Board Kit components

Image: The Trane KIT18110 furnace control board kit, showing the main circuit board, ignitor, and mounting hardware.

Zgodność

This kit is an OEM replacement for various American Standard and Trane units built after 1995. It supersedes several older control board models. Always verify compatibility with your specific furnace model before installation.

Replaces / Supersedes Part Numbers:

Commonly Found in Models:

This kit is commonly found in the following A/TDX and A/TUX Gas Furnace Models:

Komponent OEM firmy Traneamp

Image: A stamp indicating "Trane OEM Component," signifying genuine parts.

Instalacja/Konfiguracja

This procedure is intended for qualified technicians. Refer to your furnace's specific service manual for detailed wiring diagrams and safety precautions.

  1. Odłączenie zasilania: Locate the main power switch for your furnace and turn it OFF. Additionally, turn off power at the circuit breaker or fuse box. Verify power is off using a voltage metr.
  2. Płyta kontroli dostępu: Open the furnace access panel to expose the existing control board.
  3. Okablowanie dokumentów: Before disconnecting any wires, take clear photographs of all existing wiring connections to the old control board. Label wires if necessary to ensure correct re-connection.
  4. Odłącz przewody: Ostrożnie odłącz wszystkie przewody od starej płytki sterującej.
  5. Usuń starą tablicę: Unscrew or unclip the old control board from its mounting location.
  6. Zainstaluj nową płytę: Mount the new Trane KIT18110 control board using the provided bracket and screws. Ensure it is securely fastened.
  7. Podłącz okablowanie: Refer to your photographs and the wiring diagram in your furnace manual to connect all wires to the new control board. Pay close attention to terminal markings (e.g., R, W, Y, G, C).
  8. Install Ignitor: Replace the old ignitor with the new one provided in the kit, ensuring proper seating and connection to the control board via the wire harness.
  9. Bezpieczne panele: Zamknij i zabezpiecz wszystkie panele dostępowe pieca.
  10. Przywróć zasilanie: Restore power to the furnace at the circuit breaker or fuse box, then turn on the main power switch for the furnace.
  11. Operacja testowa: Initiate a heating cycle to verify proper furnace operation, including ignition, fan operation, and temperature control. Observe for any error codes or unusual behavior.

Działanie

The Trane KIT18110 control board is an integrated furnace control that manages the sequence of operation for your furnace. Once correctly installed, it will automatically control the ignition, fan, and safety functions based on signals from the thermostat and internal sensors. No direct user interaction with the control board is required for normal operation.

Refer to your furnace's user manual for instructions on setting your thermostat and general furnace operation.

Konserwacja

The control board itself typically requires no routine maintenance. However, regular maintenance of your furnace system is crucial for its longevity and efficient operation. This includes:

Always disconnect power before performing any maintenance on the furnace.

Rozwiązywanie problemów

The control board features diagnostic LED indicators that can help identify system faults. Consult your furnace's service manual for a detailed list of error codes and their meanings. Common issues and initial checks include:

If you are unable to resolve an issue, contact a qualified HVAC technician.

Specyfikacje

Numer modelu przedmiotuZestaw18110
ProducentTran
ZgodnośćAmerican Standard / Trane units built after 1995
Zawartość zestawuControl Board (CNT07541), Ignitor, Wire Harness, Bracket
Wymiary opakowania12.09 x 7.2 x 5.08 cala
Waga przedmiotu15.17 uncji

Informacje o gwarancji

Specific warranty details for the Trane KIT18110 control board kit are typically provided by the point of purchase or Trane directly. It is recommended to retain your purchase receipt and consult the official Trane warranty documentation for your specific product. Generally, OEM parts carry a limited warranty against manufacturing defects.

Wsparcie

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your authorized Trane dealer or a qualified HVAC service professional. You may also visit the official Trane webwitryny, aby uzyskać dodatkowe zasoby i informacje kontaktowe.

Powiązane dokumenty - Zestaw18110

Przedview Instrukcja montażu, obsługi i konserwacji pieca gazowego Trane & American Standard serii S8
Kompleksowy przewodnik dotyczący instalacji, obsługi i konserwacji kotłów gazowych Trane i American Standard serii S8 z przepływem w górę/w dół/poziomo 1-Stage i 2-StagPiece z wyciągiem indukowanym i silnikiem o wysokiej sprawności. Zawiera ostrzeżenia dotyczące bezpieczeństwa, specyfikacje, schematy okablowania i wskazówki dotyczące rozwiązywania problemów.
Przedview Piec gazowy Trane serii S9V2: Instrukcja instalacji, obsługi i konserwacji
Kompleksowy przewodnik dotyczący instalacji, obsługi i konserwacji urządzeń Trane i American Standard S9V2 serii 2-stagPiece gazowe kondensacyjne o zmiennej prędkości obrotowej. Obejmuje bezpieczeństwo, procedury instalacji, specyfikacje i rozwiązywanie problemów.
Przedview Biuletyn serwisowy dotyczący awarii płyt Trane i American Standard IFC – OBOWIĄZKOWA przeróbka
Oficjalny biuletyn serwisowy firm Trane i American Standard dotyczący usterek płyty Integrated Furnace Control (IFC) w określonych modelach pieców. Szczegółowo opisano kod błędu 5, modele, których dotyczy problem, oraz obowiązkowe instrukcje dotyczące przeróbek.
Przedview Instrukcja instalacji, obsługi i konserwacji pieców gazowych Trane/American Standard serii A801X
W tej obszernej instrukcji znajdują się szczegółowe instrukcje dotyczące instalacji, obsługi i konserwacji pojedynczych urządzeń Trane i American Standard serii A801X.tagPiece gazowe z ciągiem indukowanym. Zawiera ostrzeżenia dotyczące bezpieczeństwa, specyfikacje produktów, wytyczne dotyczące instalacji, procedury rozwiązywania problemów oraz wymagania dotyczące okresowego serwisowania różnych modeli.
Przedview Instrukcja instalacji zestawu do konwersji LP firmy Trane dla jednostek dachowych Precedent
Szczegółowa instrukcja instalacji dotycząca konwersji agregatów dachowych Trane Precedent™ (o pojemności od 6 do 25 ton) z zasilania gazem ziemnym na propan (LP). Zawiera ostrzeżenia dotyczące bezpieczeństwa, listę części oraz procedury krok po kroku dla wykwalifikowanego personelu.
Przedview Instrukcja instalacji urządzeń Trane serii Ultra-Low NOx dla urządzeń grzewczych/chłodzących na gaz z pakietem elektrycznym
Niniejszy podręcznik instalatora zawiera kompleksowe instrukcje dotyczące instalacji, obsługi, konserwacji i rozwiązywania problemów z pojedynczymi, gazowymi i elektrycznymi agregatami grzewczymi i chłodzącymi Trane Ultra-Low NOx Series (2-5 ton). Obejmuje on bezpieczeństwo, wymagania, kwestie elektryczne, gazowe, uruchamianie i szczegóły dotyczące podzespołów.