FEIG MRM103 Mid Range Reader Module Installation Guide

FEIG MRM103 Mid Range Reader Module Installation Guide

FEIG-LOGO

FEIG MRM103 Mid Range Reader Module

FEIG-MRM103-Mid-Range-Reader-Module-PRODUCT

MODELKI

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (1)

NOTATKA

With this edition of the document, all previous editions become void. Indications made in this manual may be changed without previous notice. Copying of this document and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design. Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guarantee for the functionality of the complete system which incorporates the subject of this document. FEIG ELECTRONIC GmbH calls explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to human health. To avoid damage, injury or death the user or application designer must take reasonably prudent steps to protect against system failures. FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this document and makes no representation that they are free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.

Instrukcje bezpieczeństwa

  • Urządzenie może być używane wyłącznie zgodnie z przeznaczeniem, przewidzianym przez producenta.
  • Instrukcja obsługi powinna być zawsze dostępna dla każdego użytkownika.
  • Nieautoryzowane zmiany oraz stosowanie części zamiennych i urządzeń dodatkowych, które nie zostały sprzedane lub zalecane przez producenta, mogą spowodować pożar, porażenie prądem lub obrażenia. Takie nieautoryzowane środki wykluczają jakąkolwiek odpowiedzialność producenta.
  • Dla urządzenia obowiązują przepisy dotyczące odpowiedzialności producenta w wydaniu obowiązującym w momencie zakupu. Producent nie ponosi odpowiedzialności prawnej za nieścisłości, błędy lub pominięcia w instrukcji lub automatycznie ustawione parametry urządzenia lub za nieprawidłowe zastosowanie urządzenia.
  • Naprawy może wykonywać tylko producent.
  • Installation, operation, and maintenance procedures have to be carried out by professional and qualified personnel.
  • Użytkowanie urządzenia i jego instalacja muszą być zgodne z krajowymi wymogami prawnymi i lokalnymi przepisami elektrycznymi.
  • Podczas pracy na urządzeniach należy przestrzegać obowiązujących przepisów bezpieczeństwa.
  • Przed dotknięciem urządzenia należy zawsze odłączyć zasilanie. Upewnij się, że urządzenie jest bez woltage poprzez pomiar. Zanikanie kontrolki działania (LED) nie jest wskaźnikiem przerwy w zasilaniu lub braku głośności w urządzeniutage!

NOTATKA:

  • Wearers of pacemakers
    • Although this device does not exceed the permissible limits for electromagnetic fields, you should keep a minimum distance of 25 cm between the device and your pacemaker and not stay in the immediate vicinity of the device or the antenna for long periods of time.

History of documentation

Rewizja Dane Opis
0e Sierpień 2025 Wersja początkowa
1e Październik 2025 Naprawiono błąd

Supported documents

NIE. Supported documents Doc.No.
[1] Więcej informacji https://www.feig.de/en/login/  
[2] Podręcznik H50420-xe-ID-B
[3] Quick Start PR(M)103-USB M50630-xde-ID-B
[4] Quick Start MR(M)103-A M50628-xde-ID-B
[5] Quick Start MR103-E M50629-xde-ID-B
[6] Quick Start MR(M)103-USBC M50627-xde-ID-B

Wyjaśnienie symboli

Symbol Wyjaśnienie
VDC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2) Objętość bezpośredniatagsymbol

Funkcja wydajności

Informacje ogólne

  • All reader variants described here have been developed for contactless data exchange with transponders whose operating frequency is 13.56 MHz.
  • The ID PR103 has an integrated antenna and works with a transponder-dependent, typical reading range of 20 cm. The reader is equipped with a USB interface for communication with the host.
  • The ID MR103 variants are equipped with a connection for an external antenna and work with a transponder-dependent, typical reading range of 40 cm.
  • The following interfaces are available for communication with the host: RS232, USB, USBC, Ethernet.
  • The “Anticollision” function enables the simultaneous reading of up to 100 x ISO15693 or 20 x I-CODE1 transponders.
  • The reader variants are available as a housing version and as a module version.

Reader type code

Typ czytnika Wersja Interfejs
79 (Hex.: 0x4F) A RS232
USB USB 2.0
USB-C USB-C
E (Ethernet) Sieć lokalna

Zakładka 1: Typ czytnika

Nadview

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (3)

Reader versions

Typ czytnika Oprogramowanie sprzętowe Wersja Interfejs
ID MR103-USB Standard Mieszkania USB
ID MRM103-USB Standard Moduł USB
ID MR103-USBC Standard Mieszkania USB-C
ID MR103-A Standard Mieszkania RS232
ID MRM103-A Standard Moduł RS232
ID MR103-E Sieć Ethernetowa Mieszkania Sieć lokalna
ID PR103-USB Standard Mieszkania USB
ID PRM103-USB Standard Moduł USB

Zakładka 2: Wersja dla czytelnika

Obsługiwane tryby pracy

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (4)

Zakładka 3: Tryb pracy

Zakres dostawy

  • 1 x Urządzenie
  • 1 x Quick Start document

Cyberbezpieczeństwo

Cyber Security (MR103-E)
Uruchomienie urządzenia

WAŻNA INFORMACJA In order to comply with the requirements of the European Radio Equipment Directive (RED) 2014/53/EU article 3 (3), points (d), the following points must be taken into account for the product ID MR103-E:

  • When using the network interface (Ethernet), it may be necessary to create at least one user to enable various functions such as changing the configuration. The user and the password MUST be set by the person who puts the device into operation on first use before it is logically connected to a network or by an authorized entity within a network where access is limited to authorized entities.
  • When security and/or network assets (keys, certificates, ethernet configuration parameters) are transferred via network interface (Ethernet) TLS encryption must be used to secure the communication.

Cyber Security related Firmware Updates

WAŻNA INFORMACJA: In order to comply with the requirements of the European Radio Equipment Directive (RED) 2014/53/EU article 3 (3), points (d), you are required to register in the FEIG download area under https://www.feig.de/en/ and subscribe to notifications for cybersecurity-related firmware and software updates for the product ID MR103-E.

Firmware downgrade

WAŻNA INFORMACJA: A firmware downgrade to older major release versions is not possible in order to prevent old major versions with known cyber security vulnerabilities from being executed on the device.

Instalacja

Housing version

  • The readers are designed for indoor applications.
  • Wall and under-counter mounting are possible with the optionally available mounting kit.

Zobacz 8.1 Wall mounting or under-counter mounting

Wymiary

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (5)

Modul version
The Module version is intended for installation in customer housings.

Modul dimension [mm]

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (6)

Interfejs ponadview i połączenia

Depending on the reader variant, different connections and interfaces are available.

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (7)

Interface designation

Złącze Opis
X1 Power supply 12 – 24V DC/       ± 10%
X2 RS232 & Power supply 12 – 24V DC/        ± 10%
X3 USB / USBC
X4 10/100Tbase Network interface (RJ45) LAN
Ant 1 Connector ext. antenna (Impedance Ω)

Zakładka 4: Opis złącza

Antenna connection ANT1

There is an SMA socket on the circuit board or on the housing for connecting the external antenna.

NOTATKA:

  • The antenna must be adjusted to the value 50 Ω (50 Ω L 15°).
  • The optimum operating quality of the antenna should be in the range QB = 10…20. To determine the operating quality, the antenna must be supplied with a 50 Ω source, e.g. a network analyzer or a frequency generator.
  • When connecting an antenna, make sure that it does not exceed the permissible limit values of the national regulations regarding radio equipment.
  • The maximum tightening torque of the SMA sockets is 0.45 Nm.

Objętość DCtage on antenna connector ANT1

Objętość DCtage can be applied from the reader to the ANT1 antenna connection. This DC voltage can be used to supply an LED, for example.

NOTATKA:

  • Objętość DCtage is only designed for low currents. The DC voltage (6,9 V± 1 V) can be loaded up to a maximum of 5mA.
  • Only antennas that are suitable for DC voltage and do not short-circuit the DC voltage may be connected.
  • When connecting other devices (e.g. VSWR meters), make sure that they are also suitable for DC voltage.
  • Ten tom DCtage is not suitable for supplying the automatic antenna tuner ID ISC.DAT.

Nadview Zasilacz

ID PR(M)103-USB X3 5 VDC / 500 mA (via USB)
ID MR(M)103-A X2 Styk 1 = masa

Pin 2 = RxD Pin 3 = TxD Pin 4 = GND

Pin 5 = 12 bis 24V DC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2)

ID MR103-E X1 External Power Supply Unit (12 bis 24V DC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2))*
ID MR(M)103-USB X1 External Power Supply Unit (12 bis 24V DC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2))*
ID MR103-USBC X3 5 V DC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2)/ 1,5A (via USBC)

Zakładka 5: Zasilacz

X1: External Power Supply*

  • The device may only be supplied by a power source in accordance with EN 62368-1 Chapter Q.1 Power sources of limited power or with a power supply unit certified in accordance with NEC Class 2/LPS.
  • For more information on available power supply units, see Accessories.

Connector for external Power Supply Unit

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (8)X2: RS232 Interface (ID MR103-A)
The transmission parameters can be configured via software protocol.

Connector X2 / Pin Assignment

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (9)X3: USB-Interface (ID PR103-USB / ID MR103-USB, USBC)
The USB interface is connected via socket X3 (ID PR103-USB / ID MR103-USB / -USBC). The assignment is standardized. The data rate of the reader is limited to 12 Mbit (USB Full Speed). A standard USBC cable can be used.

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (10) NOTATKA: Maximum length of the USB cab e: ≤ 3 m

X4: Ethernet-Interface (ID MR103-E)

  • The reader has an integrated 10/100 base-T network interface with standard RJ-45 connection. The connection is made via X4 and has automatic crossover detection in accordance with the 1000BASE-T standard.
  • For structured cabling, at least CAT5 category cables should be used. This guarantees problem-free operation at 10 Mbps or 100 Mbps.
  • A prerequisite for using the TCP/IP protocol is that each device on the network has its own IP address. All readers have a factory-set IP address.
  • The transmission parameters can be configured via software protocol.
Sieć Adres
Adres IP 192.168.10.10
Maska podsieci 255.255.255.0
Port 10001
DHCP ON

Zakładka 8: Default setting Ethernet Interface

NOTATKA:

  • The reader has a DHCP-capable TCP/IP interface.
  • A shielded STP (shielded and twisted pair) CAT5 cable must be used.

Elementy obsługi i wyświetlacza

Default settings for LED indication

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (11)

Zatwierdzenia radiowe

Deklaracja zgodności (CE)

  • Deklaracja zgodności CE
    • Hereby, FEIG ELECTRONIC GmbH declares that the radio equipment type ID PRM103 / ID MRM103 is in compliance with Directive 2014/53/EU.
    • Pełny tekst Deklaracji zgodności UE jest dostępny pod następującym adresem internetowym: https://www.feig.de/en/service/.

USA (FCC) i Kanada (IC)

NOTATKA: The RFID reader ID PR103 / MR103 contains the RFID module ID PRM103 / MRM103.

Nazwa produktu: ID PR103 / MR103
FCC ID: IC: PJMPRM103 PJMMRM103 6633A-PRM103 6633A-MRM103
Uwaga dla

Stany Zjednoczone i Kanada

To urządzenie jest zgodne z częścią 15 przepisów FCC oraz z normą RSS-210 Industry Canada.

Aby móc korzystać z urządzenia, należy spełnić dwa warunki.

(1) to urządzenie nie może powodować szkodliwych zakłóceń i

(2) to urządzenie musi akceptować wszelkie odbierane zakłócenia, w tym zakłócenia, które mogą powodować niepożądane działanie.

Unauthorized modifications may void the authority granted under Federal Communications Commission Rules permitting the operation of this device. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Informacje dotyczące narażenia na promieniowanie o częstotliwości radiowej: To urządzenie jest zgodne z limitami narażenia na promieniowanie FCC i IC określonymi dla niekontrolowanego środowiska. To urządzenie powinno być zainstalowane i obsługiwane z zachowaniem minimalnej odległości 20 cm między grzejnikiem a ciałem. Ten nadajnik nie może znajdować się w pobliżu ani działać w połączeniu z żadną inną anteną lub nadajnikiem.

NOTATKA: Zmiany lub modyfikacje tego sprzętu, które nie zostały wyraźnie zatwierdzone przez FEIG ELECTRONIC GmbH, mogą unieważnić autoryzację FCC na użytkowanie tego sprzętu.

Installation with FCC / IC Approval

FCC-/IC-NOTICE: To comply with FCC-Part 15 Rules in the United States / with IC Radio Standards in Canada, the system must be professionally installed to ensure compliance with the Part 15 certification / IC certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States / Canada.

Informacje o etykiecie

  • UThe following information must be placed at the outer side of the housing in which the reader is mounted.
  • Contains FCC ID PJMPRM103 Contains FCC ID PJMMRM103
  • Contains IC: 6633A-PRM103 Contains IC: 6633A-MRM103

Dane techniczne

Dane mechaniczne
Housing PR103 / MR103 Plastik ABS
Waga

PR103 MR103

150 gramów

150 gramów

Dimension PR103 / MR103

(szer. x wys. x gł.)

(145 x 85 x 22) mm
Dimension PR103 / MR103 Module

(szer. x wys. x gł.)

(145 x 77 x 17) mm
Weight Modul 56 gramów
Protection class PR103 / MR103 IP30
Kolorowa obudowa RAL 9018 (biały)
Dane elektryczne
Zasilacz

·         ID PR103-USB

·         ID MR103-A/-USB

·         ID MRM103-A/-USB

·         ID MR103-E

·         ID MR103-USBC

 

·         5V DC

·         12V DC up to 24V DC

·         12V DC up to 24V DC

·         12V DC up to 24V DC

·         Via USB-Type-C (Current at 1.5A)

Pobór mocy

ID PR103-USB ID MR103-A, USB, USBC, E

maks. Maks. 2.5 W. 6 W
Antena

PR(M)103-USB

zintegrowany
Antena connector MR(M)103 1x SMA-socket (50 W)
Objętość dostawtage on antenna output

MR103

6,9V DC ± 1V (5 mA) Antenna output
Częstotliwość pracy

PR103-USB ID MR103-A, USB, USBC, E

13,56MHz
Przekazywanie mocy

ID PR103-USB

ID MR103-A, USB, USBC, E

0.6W ± 2dB

1,2W ± 1dB

1,5W ± 1dB

Supported transponder ISO15693, (ISO 18000-3 MODE 1), I-CODE1
Reader modes

ID PR(M)103-USB

ID MR(M)103-A, USB, USBC, ID MR(M)103-E

ISO Host Mode, Scan Mode ISO Host Mode, Scan Mode

ISO Host Mode, Notification Mode

1 x LED 1 x multicolor LED; (green, blue, red)
Interfejsy

·         ID PR(M)103-USB

·         ID MR(M)103-A

· USB

·         RS232

·         ID MR(M)103-USB

·         IS MR(M)103-USBC

·         ID MR(M)103-E

· USB

· USB

·         Ethernet (TCP/IP)

Funkcja Short-circuit detection (antenna)

Monitorowanie temperatury

Warunki środowiskowe
Zakres temperatur -25°C do +55°C

-40°C do +85°C

Przechowywanie operacji
Wilgotność względna powietrza 5% – 95% (bez kondensacji)
Wibracja EN60068-2-6

10 Hz bis 150 Hz: 0,075 mm / 1 g

Zaszokować EN60068-2-27

Przyspieszenie: 30 g

Zatwierdzenia
Zatwierdzenie radia ·         EN 300 330

·         FCC 47 CFR-Part 15

·         RSS-Gen Issue 1, RSS-210

·         Europa / UK

·         USA

·         Canada

EMV PN-EN 301 489
Bezpieczeństwo i zdrowie PN-EN 62368-1

EN 50364

EN 18031

Niska objętośćtage Narażenie człowieka

Cyber Security (MR103-E)

Akcesoria

Numer zamówienia: Typ Opis
1688.002.00 ID NET.12V-B-EU Power Supply Unit 12V Supply unit 100 – 240V AC, (Angled plug, EU),

Output: 12V DC/      ; 50Hz / 60Hz, 700mA

3886.000.00 ID NET.12V-B-GB Power Supply Unit 12V Supply unit 100 – 240V AC, (Angled plug, GB)
3887.000.00 ID NET.12V-B-US Power Supply Unit 12V Supply unit 100 – 240V AC, (Angled plug, US)
7224.000.00 ID MS.MR103/PR103-A Wall mounting or under-counter mounting
7102.000.00 ID CAB.RS-T Cable for RS232 and Power Supply (ID MR103-A)
7103.000.00 ID CAB.USB-AC USB Interface cable, USB-A auf USBC
7104.000.00 ID CAB.USB-CC USB Interface cable, USBC auf USBC
Anteny zewnętrzne
1663.000.00 Identyfikator ISC.ANT340/240-A Dim.: Protection.: 340mm x 240mm x 9mm IP20
2396.000.00 Identyfikator ISC.ANT340/240-B Antena zewnętrzna bez obudowy
3249.000.00 Identyfikator ISC.ANT310/310-A Dim.: Protection.: 318mm x 338mm x 30mm IP65
3512.000.00 Identyfikator ISC.ANTS370/270 Dim.: Protection.: 370mm x 270mm x 27mm IP20
6612.000.00 ID ANT240/180-A Dim.: Protection: 40mm x 180mm x 13mm IP30
6616.000.00 ID ANTS240/180-A Dim.: Protection: 240mm x 180mm x 15mm IP30
1968.000.00 Identyfikator ISC.ANT100/100-A External antenna without housing Dim.:                40mm x 30mm x 6mm
1967.000.00 Identyfikator ISC.ANT40/30-A Antena zewnętrzna bez obudowy

Dim.:                100mm x 100mm x 6mm

Zakładka 10: Akcesoria

Wall mounting or under counter mounting

  • Remove the screws on the back of the reader.
  • The mounting brackets are fastened with the previously removed screws.
  • They can also be mounted rotated by 90° as an option.

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (12)

Notatka: The mounting kit “ID MS.MR103/PR103-A” includes the four mounting brackets (See Accessories).

Serial Data Cable ID CAB.RS-T

SZPILKA Sygnał Farbe / Color X2
1 GND Żółty FEIG-MRM103-Mid-Range-Reader-Module-FIG- (13)
2 RxD Pomarańczowy
3 TxD Brązowy
4 GND Czarny
5 12 bis 24V DC/FEIG-MRM103-Mid-Range-Reader-Module-FIG- (2) Czerwony

FEIG-MRM103-Mid-Range-Reader-Module-FIG- (14)

  • Dokument: Instalacja
  • Id-Nr. Document Version: M50720-0e-ID-B
  • Data: 30.10.25

INFORMACJE KONTAKTOWE

  • © Prawa autorskie
  • All brand names, product names or trademarks mentioned are the property of their respective owners.
  • FEIG ELECTRONIC GmbH
  • Industriestrasse 1a
  • 35781 Weilburg, Niemcy
  • Telefon: +49 6471 3109-0
  • Strona główna: https://www.feig.de/en/
  • E-mail: identyfikacja-support@feig.de.

Często zadawane pytania

  • Czy mogę dokonać modyfikacji w urządzeniu?
    • No, unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
  • Who can perform repairs on the device?
    • Naprawy może wykonywać tylko producent.
  • What should I do before handling the device?
    • Przed dotknięciem urządzenia należy zawsze odłączyć zasilanie. Upewnij się, że urządzenie jest bez woltage by measuring. The fading of an operation control (LED) is no indicator for an
    • interrupted power supply or the device being out of voltage!
  • Gdzie mogę znaleźć najnowszą wersję instrukcji?
    • With this edition of the document, all previous editions become void. Indications made in this manual may be changed without previous notice. For the most current information, it is recommended to contact FEIG ELECTRONIC GmbH.

Dokumenty / Zasoby

PDF thumbnailMRM103 Mid Range Reader Module
Installation Guide · PJMPRM103, PRM103-USB, MRM103-USB, MR103-A, MR103-E, MR103-USBC, M50720-0e-ID-B, MRM103 Mid Range Reader Module, MRM103, Mid Range Reader Module, Mid Range Reader Module, Reader Module, Module

Odniesienia

Zadaj pytanie

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Zadaj pytanie

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.