Minuteman EN450G

Minuteman EN450G 450VA Standby UPS User Manual

Model: EN450G

1. Wprowadzenie

This manual provides essential instructions for the safe and efficient operation of your Minuteman EN450G 450VA Standby Uninterruptible Power Supply (UPS). The EN450G is designed to provide reliable backup power and surge protection for various electronic devices, including gaming consoles, desktop PCs, home office equipment, and network devices. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Ważne instrukcje bezpieczeństwa

WARNING: To reduce the risk of electric shock, fire, or injury to persons, read all instructions before using this product.

3. Koniec produktuview

The Minuteman EN450G UPS provides comprehensive power protection. Familiarize yourself with its components:

Minuteman EN450G 450VA Standby UPS showing front and top view with outlets and controls.

Rysunek 1: Minuteman EN450G UPS Unit. This image displays the Minuteman EN450G UPS unit. The front panel features the 'Minuteman Power Technologies' logo, two USB charging ports, and control buttons. The top surface shows four 'Battery & Surge' protected outlets and four 'Surge Only' outlets, clearly labeled. The unit is black and designed for compact placement.

3.1 Funkcje panelu przedniego

3.2 Funkcje panelu tylnego

4. Konfiguracja i instalacja

4.1 Rozpakowanie

Ostrożnie rozpakuj UPS i sprawdź, czy nie ma uszkodzeń powstałych podczas transportu. W przypadku stwierdzenia uszkodzeń nie uruchamiaj urządzenia i skontaktuj się ze sprzedawcą.

4.2 Umieszczenie

The EN450G is designed for versatile placement:

Ensure the installation area is clean, dry, and has adequate ventilation. Avoid placing the UPS near heat-emitting appliances or in direct sunlight.

4.3 Podłączanie do zasilania

  1. Sprawdź, czy UPS jest wyłączony.
  2. Plug the UPS power cord into a grounded 120V AC wall outlet.
  3. Allow the UPS to charge for at least 8 hours before initial use to ensure optimal battery runtime.

4.4 Podłączanie urządzeń

CAUTION: Do not connect laser printers or shredders to the battery backup outlets, as their high power draw can overload the UPS.

5. Działanie

5.1 Włączanie/wyłączanie UPS-a

5.2 Wskaźniki stanu

The front panel LEDs provide information about the UPS status:

5.3 Czas pracy baterii

The EN450G provides approximately 3 minutes of runtime at full load (450VA/255W) and 11 minutes at half load. Actual runtime may vary based on connected equipment and battery age.

6. Konserwacja

6.1 Wymiana baterii

The EN450G features a hot-swappable Sealed Lead Acid (SLA) battery, allowing replacement without interrupting power to connected devices. Batteries typically last 3-5 years depending on usage and environmental conditions. A flashing red LED or continuous alarm may indicate a need for battery replacement.

  1. Ensure the UPS is connected to AC power and operating normally.
  2. Locate the battery access panel (refer to product diagram if available).
  3. Carefully slide out the old battery pack.
  4. Insert the new, fully charged replacement battery pack, ensuring correct orientation.
  5. Zabezpiecz panel dostępu do akumulatora.
  6. Allow the new battery to charge for 8-12 hours to reach full capacity.

WARNING: Use only approved replacement batteries. Improper battery replacement can result in fire or explosion. Dispose of old batteries properly at a recycling facility.

6.2 Czyszczenie

Okresowo czyść zewnętrzną część UPS-a miękką, suchą ściereczką. Nie używaj płynów ani środków czyszczących w aerozolu. Upewnij się, że otwory wentylacyjne są czyste i wolne od kurzu i zanieczyszczeń.

7. Rozwiązywanie Problemów

This section addresses common issues you may encounter with the EN450G UPS. If a problem persists after attempting the solutions below, contact technical support.

ProblemMożliwa przyczynaRozwiązanie
UPS nie włącza się.Akumulator nie jest podłączony lub jest rozładowany.
Przewód zasilający nie jest podłączony.
Ensure battery is properly connected and charged.
Verify power cord is securely plugged into wall outlet and UPS.
UPS beeps continuously or red LED is solid.Battery low or fault condition.
Overload on battery outlets.
Allow battery to charge. If problem persists, battery may need replacement.
Disconnect non-essential devices from battery outlets. Check circuit breaker.
UPS często działa na zasilaniu akumulatorowym.Unstable incoming AC power.
UPS sensitivity setting (if applicable, though not specified for this model).
Check the quality of your incoming AC power. Consider connecting to a different outlet.
No power from surge-only outlets.Zadziałał wyłącznik automatyczny.Press the circuit breaker reset button on the rear panel. Reduce load if necessary.

8. Specyfikacje

FunkcjaSzczegół
ModelEN450G
Pojemność450VA/255W
Wejście/Wyjście Objętośćtage120 V prądu zmiennego
Przebieg wyjściowySymulowana fala sinusoidalna
Punkty sprzedaży4 x Battery & Surge Protected, 4 x Surge Only
Typ bateriiSealed Lead Acid (SLA), Hot-Swappable
Typical Runtime (Full Load)Do 3 minut
Typical Runtime (Half Load)Do 11 minut
Wymiary (gł. x szer. x wys.)12.8 x 5.7 x 4.1 cala (32.5 x 14.5 x 10.4 cm)
Waga4.4 funtów (2 kg)
Opcje montażuDesktop, Floor, Wall Mount

9. Informacje o gwarancji

Please refer to the warranty card included with your product or visit the manufacturer's webSzczegółowe warunki gwarancji znajdziesz na stronie. Zachowaj dowód zakupu na wypadek roszczeń gwarancyjnych.

10. Wsparcie techniczne

If you require technical assistance or have questions regarding your Minuteman EN450G UPS, please contact your dealer or the manufacturer's customer support. Have your model number (EN450G) and serial number ready when contacting support.

For more information, you may visit the official Minuteman webstrona.

Powiązane dokumenty - EN450G

Przedview Instrukcja obsługi zasilacza UPS Minuteman Enspire Series (EN450G, EN600GU, EN750G)
Niniejsza kompleksowa instrukcja obsługi zasilacza UPS serii Minuteman Enspire (modele EN450G, EN600GU, EN750G) zawiera podstawowe wskazówki dotyczące instalacji, obsługi, bezpieczeństwa, rozwiązywania problemów i specyfikacji zapewniających niezawodną ochronę zasilania.
Przedview Instrukcja obsługi zasilacza UPS serii Enspire EN350 / EN550 firmy MINUTEMAN
Kompleksowa instrukcja obsługi zasilaczy UPS serii MINUTEMAN Enspire, modele EN350 i EN550. Zawiera szczegółowe informacje na temat instalacji, obsługi, elementów sterujących, wskaźników, rozwiązywania problemów, wymiany baterii, specyfikacji, gwarancji i deklaracji zgodności.
Przedview Minuteman RPM-LCD UPS Series Quick Install Guide and Specifications
Quick installation guide, features, and warranty information for the Minuteman RPM-LCD UPS Series. Learn how to install and configure your network UPS.
Przedview Instrukcja obsługi zasilacza UPS Minuteman Endeavor serii 5-10 kVA w obudowie rack/tower
Instrukcja obsługi zasilacza UPS Minuteman Endeavor z serii, obejmująca modele rack/tower o mocy 5–10 kVA. Zawiera instrukcje dotyczące instalacji, konfiguracji, obsługi i rozwiązywania problemów w zakresie ochrony zasilania.
Przedview Minuteman UPS Quick Reference Guide
Quick reference guide detailing features and specifications for Minuteman Power Technologies' range of UPS systems, including Entry Level, Rackmount (EXR Series), and Online (Encompass, Endeavor, ED6/10KTF Series) UPS units. Compares models, UPS topology, load capacity, output signals, receptacles, and other key features.
Przedview Minuteman SV Online Series UPS User's Manual
Comprehensive user manual for the Minuteman SV Online Series UPS, detailing installation, operation, safety, maintenance, and specifications. Covers models from 1kVA to 3kVA.