Wstęp
This manual provides essential information for the proper installation, operation, and maintenance of your X-Sense Carbon Monoxide Detector, Model XC0K-SN. This device is designed to detect carbon monoxide (CO) levels in your home, providing a crucial layer of safety for your family. It features a built-in 10-year battery for continuous protection without the need for replacements or calibration.
W pakiecie
Przed instalacją sprawdź, czy wszystkie komponenty są obecne.
- 1 × Carbon Monoxide Alarm XC0K-SN with Sealed 10-Year Lithium Battery
- 1 × Instrukcja obsługi
- 2 × śruby
- 2 × kołki kotwiące
- 1 × Drill Hole Spacing Indicator Label

Image: Included components of the X-Sense XC0K-SN Carbon Monoxide Detector.
Konfiguracja i instalacja
The X-Sense XC0K-SN Carbon Monoxide Detector offers flexible placement options, allowing it to be mounted on a wall or placed on a flat surface like a desk or countertop.
Montaż na ścianie
- Separate the mounting bracket from the detector by twisting the detector counter-clockwise.
- Use the provided screws and anchor plugs to secure the mounting bracket to your desired wall location. Ensure the location is appropriate for CO detection (refer to local regulations and safety guidelines).
- Align the detector with the mounted bracket and twist clockwise until it locks securely into place.
Desktop/Countertop Placement
For flexible placement without wall mounting, simply place the detector on a stable, flat surface. Ensure it is in a location where its alarm can be heard and is not obstructed.

Image: Flexible installation options for the X-Sense CO Detector, showing wall mounting and desktop placement.
Video: A demonstration of how to install the X-Sense Carbon Monoxide Detector, including separating the mounting plate and securing the device.
Instrukcja obsługi
The X-Sense XC0K-SN is designed for straightforward operation, providing clear indicators for its status and detected CO levels.
Wyświetlacz LCD
The clear, informative LCD displays real-time carbon monoxide (CO) levels in parts per million (PPM) and the battery status. The display only illuminates during button operation or when an event (fault or alarm) is triggered, ensuring it does not disturb sleep.

Image: The LCD display showing CO levels and battery status, along with the tri-color LED indicator guide.
Tri-Color LED Indicator
- Zielony: Oznacza normalną pracę.
- Żółty: Warns of a fault or malfunction.
- Czerwony: Indicates an alarm, signaling dangerous CO levels. Move to fresh air and call 911 immediately.
Przycisk szczytowy
Pressing the exclusive Peak Button will display the highest CO level detected since the last reset. This feature allows you to check for potential risks even if you have been away from home.

Image: The CO Peak Memory feature showing the highest detected CO level.
Przycisk testu/wyciszania
The 'TEST/SILENCE' button allows you to test the alarm's functionality and silence it during an alarm event. Regular testing is recommended to ensure the device is working correctly.
Konserwacja
The X-Sense XC0K-SN Carbon Monoxide Detector is designed for minimal maintenance due to its built-in 10-year sealed lithium battery.
- Bateria: The high-performance lithium battery is sealed and designed to last the entire 10-year lifespan of the device. No battery replacements or calibration are needed.
- Czyszczenie: Regularnie czyść zewnętrzną część detektora miękką, miękką szmatką.amp cloth to prevent dust buildup. Do not use cleaning agents or solvents.
- Testowanie: Press the 'TEST/SILENCE' button periodically (e.g., monthly) to ensure the alarm sounds and the device is functioning correctly.
Rozwiązywanie problemów
If your X-Sense XC0K-SN detector indicates a fault or alarm, follow these steps:
- Żółta dioda LED (błąd): If the yellow LED illuminates, it indicates a device malfunction. Refer to the detailed user manual for specific fault codes or contact customer support.
- Czerwona dioda LED (Alarm): If the red LED illuminates and the alarm sounds, it indicates dangerous levels of carbon monoxide. Immediately move to fresh air and call 911 or your local emergency services. Do not re-enter the premises until it has been deemed safe by professionals.
- Brak wyświetlacza: If the LCD display is not showing information, press the 'TEST/SILENCE' button to activate it. If it remains blank, the device may be faulty or at the end of its lifespan.
Informacje dotyczące bezpieczeństwa tlenku węgla
Carbon monoxide is a colorless, odorless, and tasteless gas that can be deadly. It is often referred to as 'The Silent Killer'.

Image: Statistics highlighting the dangers of carbon monoxide poisoning.
Possible Symptoms of CO Poisoning
Exposure to carbon monoxide can cause various symptoms, which may be mistaken for other illnesses:
- Slight headache
- Mdłości
- Wymioty
- Dezorientacja
- Szybkie tętno
- Drgawki
Installing a CO alarm in every room helps protect against this invisible threat.

Image: Visual representation of common symptoms associated with carbon monoxide poisoning.
Specyfikacje
| Marka | Zmysł X |
| Numer modelu | XC0K-SN |
| Źródło zasilania | Battery Powered (Built-in 10-Year Lithium Battery) |
| Kolor | Biały |
| Wymiary produktu | 1.2" gł. x 3.7" szer. x 3.7" wys. (9.5 × 9.5 × 3.1 cm) |
| Typ alarmu | Słyszalny |
| Typ czujnika | Elektrochemiczny |
| Waga przedmiotu | 6.7 uncji |
| UPC | 810194782329 |
Gwarancja i wsparcie
X-Sense offers the following for your XC0K-SN Carbon Monoxide Detector:
- 60-dniowa gwarancja zwrotu pieniędzy: Dla Twojego spokoju ducha.
- 5-year quality warranty: Covering manufacturing defects and performance issues.
- Dożywotnia pomoc techniczna: Assistance with any questions or issues you may encounter.
For technical support or warranty claims, please refer to the contact information provided in the full user manual or visit the official X-Sense webstrona.