ACiQ ACiQ-K09W-W-HP230B

ACiQ 20 SEER2 Essentials 9000 BTU Mini Split AC/Heating System User Manual

Model: ACiQ-K09W-W-HP230B

1. Koniec produktuview

This manual provides essential information for the safe and efficient operation of your ACiQ 20 SEER2 Essentials 9000 BTU Mini Split AC/Heating System. This ductless heat pump system is designed to provide both cooling and heating for spaces approximately 250-400 sq. ft. in size, operating on 208/230V power.

Przed instalacją, obsługą lub konserwacją prosimy o dokładne zapoznanie się z niniejszą instrukcją. Zachowaj ją do wykorzystania w przyszłości.

ACiQ 20 SEER2 Essentials Mini Split System components: indoor unit, outdoor unit, remote control, and smartphone displaying the control app.

Obraz: Ponadview of the ACiQ Mini Split System, showing the indoor unit, outdoor condenser, remote control, and a smartphone interface for WiFi control.

2. Informacje dotyczące bezpieczeństwa

3. Co jest zawarte

Your ACiQ Mini Split System package includes the following components:

Diagram showing all included components of the ACiQ Mini Split System, numbered and labeled.

Image: A visual representation of all items included in the ACiQ Mini Split package, such as the indoor unit, outdoor unit, line set, remote, and various installation accessories.

  1. Jednostka wewnętrzna (urządzenie do przetwarzania powietrza)
  2. Jednostka zewnętrzna (skraplacz)
  3. Zdalne sterowanie
  4. 16ft Line Set (pre-charged for this length)
  5. Czapka ścienna
  6. Linie spustowe
  7. Kable zasilające
  8. Sprzęt montażowy (śruby, kotwy)
  9. Baterie AAA (do pilota)
  10. Instrukcja obsługi (ten dokument)
  11. Additional small parts like rubber feet, plastic wrap, plasticine, and a remote mount.

4. Wytyczne dotyczące instalacji

As stated in the safety information, installation of this ACiQ Mini Split System requires a qualified HVAC professional. The following points are general guidelines and not a substitute for professional expertise.

Ważna uwaga: The unit comes pre-charged with refrigerant for up to a 25ft line set. If your line set is shorter, a professional will still need to vacuum the lines. If a longer line set is used, additional refrigerant may be required, which must be added by a certified technician.

5. Instrukcja obsługi

5.1 Obsługa pilota zdalnego sterowania

The remote control allows you to manage all functions of your ACiQ Mini Split System. Insert the provided AAA batteries before first use.

Diagram showing the remote control with icons for various features like I Feel Mode, Sleep Mode, Eco Mode, Mute Mode, Timers, and Turbo Mode.

Image: Remote control features, illustrating icons for I Feel Mode, Sleep Mode, Eco Mode, Mute Mode, Timers, and Turbo Mode.

5.2 WiFi Control (Smart Device App)

Your ACiQ Mini Split System is equipped with built-in WiFi, allowing control via a smart device (iOS or Android) from anywhere. The app is compatible with Amazon Alexa, Google Assistant, and IFTTT.

A person smiling while using a smartphone to control the ACiQ Mini Split system via the Smart Life app, demonstrating WiFi control.

Image: A user operating the ACiQ system remotely via a smartphone app, highlighting the WiFi control feature.

  1. Pobierz aplikację: Pobierz aplikację „Smart Life” ze sklepu z aplikacjami na swoim urządzeniu (iOS lub Android).
  2. Zarejestruj się/Zaloguj: Create an account or log in to the Smart Life app.
  3. Dodaj urządzenie: Follow the in-app instructions to add your ACiQ Mini Split System. This typically involves putting the unit into pairing mode (refer to the full manual for specific steps) and connecting it to your home WiFi network.
  4. Kontrola: Once connected, you can control all functions of the unit, including mode, temperature, fan speed, and scheduling, from your smartphone or tablet.
  5. Integracja inteligentnego domu: Link the Smart Life app with Amazon Alexa, Google Assistant, or IFTTT for voice control and advanced automation.

6. Konserwacja

Regular maintenance ensures optimal performance and longevity of your ACiQ Mini Split System. Always disconnect power to the unit before performing any maintenance.

7. Rozwiązywanie Problemów

Przed skontaktowaniem się z obsługą klienta prosimy o zapoznanie się z poniższymi typowymi problemami i rozwiązaniami.

ProblemMożliwa przyczynaRozwiązanie
Jednostka się nie włącza.Brak zasilania, rozładowane baterie w pilocie, zadziałał wyłącznik automatyczny.Sprawdź zasilanie, wymień baterie w pilocie, zresetuj wyłącznik automatyczny.
Niewystarczające chłodzenie/ogrzewanie.Dirty air filters, blocked outdoor unit, wrong mode selected, temperature setting incorrect, low refrigerant.Clean air filters, clear outdoor unit, select correct mode, adjust temperature, contact professional for refrigerant check.
Wyciek wody z jednostki wewnętrznej.Blocked drain line, improper installation.Check and clear drain line, contact professional for inspection.
Niezwykły hałas.Luźne części, zablokowany wentylator, problem ze sprężarką.Turn off unit and inspect for obstructions. If noise persists, contact professional.
Pilot nie działa.Wyczerpane baterie, przeszkody pomiędzy pilotem a urządzeniem, awaria pilota.Replace batteries, remove obstructions, try resetting the remote.

For issues not listed here or if solutions do not resolve the problem, please contact ACiQ customer support or a qualified HVAC technician.

8. Specyfikacje

Diagram showing the dimensions of the indoor and outdoor units, along with key specifications like power supply, cooling/heating BTU, SEER2/EER, estimated coverage area, and indoor noise levels.

Image: Technical specifications and dimensions for the ACiQ Mini Split Indoor and Outdoor Units.

FunkcjaSzczegół
Numer modeluACiQ-K09W-W-HP230B / ACiQ-K09Z-HP230B
Pojemność9,000 BTU (0.75 tona)
SEER2 Efficiency20.0
Zasilacz230V~ / 60Hz / 1Ph
Zakres operacyjny chłodzenia5°F to 122°F outdoor temperature
Zakres działania ogrzewania-4°F to 86°F outdoor temperature
Szacowany obszar zasięgu250-400 stóp kwadratowych
Wymiary jednostki wewnętrznej (wys. x szer. x gł.)7.99" x 31.92" x 11.49"
Outdoor Unit Dimensions (H x W x D)19.60" x 30.98" x 11.41"
Poziom hałasu w pomieszczeniuJuż od 28 dBA
Typ czynnika chłodniczegoR454B
Cechy specjalneBuilt-in WiFi, Ultra-quiet operation, Full installation kit, Heats in -4°F temps

9. Gwarancja i wsparcie

ACiQ provides a comprehensive warranty for your peace of mind.

Warranty information graphic showing '6-Year Compressor & 4-Year Parts Warranty' and 'Best in Class Customer Service' with a shield icon.

Image: ACiQ warranty details, indicating 6-year compressor and 4-year parts coverage.

Prosimy zachować dowód zakupu w celach gwarancyjnych.

Powiązane dokumenty - ACiQ-K09W-W-HP230B

Przedview Instalacja i instrukcja obsługi klimatyzatora ACiQ Essentials Mini-Split i skraplacza
Kompleksowa instrukcja instalacji i obsługi systemów klimatyzacji i skraplaczy ACiQ Essentials Mini-Split, obejmująca środki ostrożności, identyfikację części, obsługę zdalnego sterowania, procedury instalacji, testy sprawnościowe, konserwację i rozwiązywanie problemów dla różnych modeli. Instrukcja zawiera również kluczowe informacje dotyczące serwisowania systemów wykorzystujących łatwopalny czynnik chłodniczy R454B, ze szczególnym uwzględnieniem protokołów bezpieczeństwa i zgodności z przepisami. Jest ona przeznaczona dla profesjonalnych instalatorów i użytkowników końcowych, aby zapewnić bezpieczną i wydajną pracę systemów pomp ciepła ACiQ Mini-Split.
Przedview ACiQ Standard Single-Zone Mini Split Installation and Owner's Manual
Comprehensive guide for installing and operating ACiQ Standard Single-Zone Mini Split air conditioning systems. Covers safety precautions, unit specifications, installation procedures, maintenance, and troubleshooting.
Przedview Instrukcja serwisowa kasety sufitowej ACiQ Slim i skraplacza platynowego
Instrukcja serwisowa kasetonów sufitowych ACiQ Slim i skraplaczy Platinum, szczegółowo opisująca bezpieczeństwo, instalację, konserwację i rozwiązywanie problemów dla modeli SCC i ACIQ-ZPL.
Przedview ACiQ 9K-24K Standardowe systemy grzewcze jednostrefowe: Instalacja i instrukcja obsługi
Instrukcja instalacji i obsługi klimatyzatorów ACiQ 9K-24K Standard Heat Single-Zone. W tym przewodniku szczegółowo opisano instalację, obsługę, bezpieczeństwo i konserwację klimatyzatorów ACiQ, w tym specyfikację modelu i informacje o czynniku chłodniczym R454B.
Przedview Instrukcja montażu skraplacza jednostrefowego ACiQ Extreme Heat i centrali wentylacyjnej z kanałem ukrytym
Instrukcja instalacji systemów ACiQ Extreme Heat ze skraplaczem jednostrefowym i kanałowym systemem uzdatniania powietrza (modele ACIQ-09CD-HH-MC do ACIQ-60CD-HH-MC i ACIQ-09ZPL-HP230C do ACIQ-60ZPL-HP230C). Zawiera informacje dotyczące bezpieczeństwa, instrukcje instalacji i specyfikacje.
Przedview Instalacja i instrukcja obsługi ściennego urządzenia do przetwarzania powietrza ACiQ i jednostrefowego skraplacza Extreme Heat
W niniejszej instrukcji znajdują się szczegółowe wytyczne dotyczące instalacji, obsługi i bezpieczeństwa montowanych na ścianie urządzeń klimatyzacyjnych ACiQ oraz jednostrefowych skraplaczy odpornych na wysokie temperatury, obejmujących modele od ACIQ-06W-HH-MD do ACIQ-24ZPL-HP230C.