Perlegear PGSER02B

Perlegear 10U Open Frame Network Rack Instruction Manual

Model: PGSER02B

Marka: Perlegear

1. Wprowadzenie

This manual provides detailed instructions for the assembly, installation, and operation of your Perlegear 10U Open Frame Network Rack (Model PGSER02B). Please read this manual thoroughly before installation to ensure proper setup and safe use. Keep this manual for future reference.

Perlegear 10U Open Frame Network Rack, front view with two vented shelves installed.

Figure 1: Perlegear 10U Open Frame Network Rack with shelves.

2. Informacje dotyczące bezpieczeństwa

Observe the following safety precautions during assembly and use:

  • Przed montażem należy upewnić się, że wszystkie elementy są obecne i nieuszkodzone.
  • Do not exceed the maximum load capacity of 200 lbs for the rack and 22 lbs for the top panel.
  • When wall-mounting, ensure the mounting surface (e.g., wood studs, concrete wall) can safely support the rack's weight and its contents. Do not mount on drywall alone.
  • Użyj odpowiednich narzędzi i dokładnie wykonaj wszystkie kroki instalacji.
  • Trzymaj dzieci i zwierzęta domowe z dala od miejsca montażu.

3. Zawartość opakowania

Sprawdź, czy w pakiecie znajdują się wszystkie części:

Diagram showing all components included in the Perlegear 10U Network Rack package: Rack Frame x2, Shelf x2, Back Brace x2, Front Brace x2, M6 Bolt x40, Cage Nut x8, M6 Nut x12, Wall Anchor x6, Lag Screw x6, Wall Plate Template.

Rysunek 2: Pełna zawartość opakowania.

  • Rack Frame (x2)
  • Półka (x2)
  • Back Brace (x2)
  • Front Brace (x2)
  • Śruba M6 (x40)
  • Cage Nut (x8)
  • Nakrętka M6 (x12)
  • Kotwa ścienna (x6)
  • Lag Screw (x6)
  • Wall Plate Template (x1)

4. Specyfikacje

FunkcjaSpecyfikacja
Numer modeluPGSER02B
Rack Units (U)10U
Wymiary produktu (Gł. x Szer. x Wys.)20.12" x 20.5" x 19.39" (51.1 cm x 52.1 cm x 49.2 cm)
Waga przedmiotu30.5 funta (13.8 kg)
TworzywoStal walcowana na zimno
KolorCzarny
Max Load Capacity (Rack)200 funta (90.7 kg)
Max Load Capacity (Top Panel)22 funta (10 kg)
Zgodność19-inch networking, AV, and IT equipment
Diagram showing the product dimensions of the Perlegear 10U Open Frame Network Rack, including depth, width, and height, along with a visual representation of the included hardware kit.

Figure 3: Product Dimensions and Hardware Kit Overview.

5. Konfiguracja i instalacja

The Perlegear 10U Open Frame Network Rack offers flexible installation options: wall-mounted or floor-standing. Follow these steps for assembly and installation.

5.1. Montaż zakończonyview

Three-step diagram showing the assembly process: 1. Assemble Frame, 2. Mount to Wall, 3. Install Shelves.

Figure 4: Simple Setup Overview.

5.2 Szczegółowe kroki montażu

Aby zapoznać się z wizualną instrukcją, obejrzyj poniższy oficjalny film instruktażowy dotyczący instalacji:

Video 1: Perlegear 10U Network Rack Installation Tutorial. This video demonstrates the step-by-step assembly and installation process for the rack.

  1. Złóż ramę:
    • Identify the Left and Right Frames, Back Braces, and Front Braces.
    • Attach the Back Braces to the bottom of the Left and Right Frames using M6 Bolts and M6 Nuts. Ensure the side with three holes on the frame faces the front.
    • Attach the Front Braces to the top of the Left and Right Frames, again ensuring the side with three holes faces the front. The 'PERLEGEAR' logo on the front brace should be visible.
    • Tighten all M6 Nuts using a PH2 or PZ2 screwdriver and a 10mm wrench for secure assembly.
  2. Zainstaluj półki:
    • Insert the two 1U vented shelves into the desired rack unit positions.
    • Utilize the provided shelf reinforcement brackets to support the shelves and prevent sagging, especially for heavier equipment. These brackets can be installed on one shelf or across two different shelves for added stability.
    Diagram illustrating two options for shelf reinforcement: installing both brackets on one shelf or installing brackets on two different shelves.

    Figure 5: Shelf Reinforcement Options.

  3. Opcje montażu:
    • Stojące na podłodze: Place the assembled rack on a stable, level surface. The rack includes caster holes at the bottom for optional mobility (casters not included).
    • Naścienny: Use the provided drilling template to mark pilot holes. Mount the rack to 16-inch wood studs (without anchors) or concrete walls (with anchors) using the lag screws. Ensure the rack is securely fastened before loading equipment.
    Image showing the Perlegear 10U rack in two configurations: wall-mounted with equipment and floor-standing with a laptop on top and equipment inside.

    Figure 6: Flexible Setup - Wall-mounted and Floor-standing configurations.

6. Instrukcja obsługi

Once assembled and installed, the Perlegear 10U Open Frame Network Rack is ready for use.

6.1. Instalacja sprzętu

  • Install your 19-inch rack-mounted networking, AV, and IT equipment into the rack units.
  • Utilize the two 1U vented shelves for non-rack-mountable devices such as smaller switches, storage devices, or UPS units.
  • Ensure proper cable management to maintain airflow and prevent obstruction.
Image showing a wall-mounted Perlegear 10U rack filled with various 19-inch networking and AV equipment, highlighting the 10U space and compatibility with 16-inch wood studs.

Figure 7: Rack with 10U Space and Equipment.

6.2. Airflow and Cooling

The open frame design and vented shelves promote optimal airflow, which is crucial for keeping your networking, audio, and video equipment cool and preventing overheating.

Diagram showing a wall-mounted Perlegear 10U rack with equipment, illustrating airflow arrows to demonstrate how the open rack and vented shelves help improve cooling.

Figure 8: Enhanced Airflow for Equipment Cooling.

6.3. Możliwość rozbudowy

This server rack features an expandable design. You can stack two 10U racks to create a 20U rack, doubling your storage capacity for growing equipment needs. Ensure to remove the top panel of the bottom rack when stacking.

Image showing two Perlegear 10U racks stacked to form a 20U rack, with a close-up of the caster holes at the bottom (casters not included).

Figure 9: Stackable Design for Increased Capacity.

Image showing a Perlegear 10U rack with equipment, positioned under a staircase, demonstrating how additional items can be stored on the top surface of the rack.

Figure 10: Utilizing the Top Surface for Additional Storage.

7. Konserwacja

Regular maintenance ensures the longevity and optimal performance of your network rack:

  • Czyszczenie: Wipe the rack surfaces with a soft, dry cloth to remove dust. For stubborn marks, use a mild, non-abrasive cleaner.
  • Kontrola: Periodically check all bolts and nuts to ensure they remain tight. Re-tighten if necessary.
  • Kontrola obciążenia: Verify that the total weight of equipment does not exceed the maximum load capacity.

8. Rozwiązywanie Problemów

Jeśli napotkasz jakiekolwiek problemy, weź pod uwagę następujące kwestie:

  • Niestabilność stojaka: Ensure all bolts and nuts are securely tightened. If wall-mounted, confirm the mounting hardware is correctly installed into appropriate structural supports.
  • Equipment Overheating: Check for proper cable management that might obstruct airflow. Ensure the rack is not placed in an enclosed space without adequate ventilation.
  • Difficulty Installing Equipment: Verify that your equipment is 19-inch rack-mountable. Ensure cage nuts are correctly inserted into the square holes before attaching equipment with M6 bolts.

9. Gwarancja i wsparcie

Perlegear products are designed for durability and performance. For warranty information, technical support, or to purchase replacement parts, please visit the official Perlegear webodwiedź witrynę lub skontaktuj się z obsługą klienta za pośrednictwem sprzedawcy.

Powiązane dokumenty - PGSER02B

Przedview Instrukcja obsługi stojaka komputerowego Perlegear PGSER02
Szczegółowa instrukcja montażu i instalacji szafy serwerowej Perlegear PGSER02. Zawiera listę części, wymagane narzędzia, ostrzeżenia dotyczące bezpieczeństwa oraz instrukcje krok po kroku dotyczące montażu na ścianach szkieletowych i z litego betonu.
Przedview Instrukcja obsługi stojaka pod telewizor Perlegear PGTVMC04
Kompleksowa instrukcja montażu i bezpieczeństwa mobilnego stojaka pod telewizor Perlegear PGTVMC04 z kółkami. Niniejsza instrukcja zawiera szczegółowe instrukcje, listy części, specyfikacje sprzętowe oraz procedury krok po kroku dotyczące bezpiecznego montażu telewizorów i półek.
Przedview Najczęściej zadawane pytania (FAQ) dotyczące uchwytu ściennego do telewizora Perlegear
Znajdź odpowiedzi na najczęstsze pytania dotyczące uchwytów ściennych do telewizorów Perlegear, w tym dotyczące wzorów VESA, typów ścian, problemów z instalacją i sposobów rozwiązywania problemów.
Przedview Instrukcja obsługi stojaka pod telewizor Perlegear PGFS06
Kompleksowa instrukcja obsługi stojaka pod telewizor Perlegear PGFS06. W tym przewodniku znajdziesz szczegółowe instrukcje dotyczące sprawdzenia kompatybilności, montażu, montażu telewizora, instalacji półki, organizacji kabli i regulacji, co gwarantuje bezpieczną i optymalną konfigurację telewizora.
Przedview Instrukcja montażu stojaka pod telewizor PERLEGEAR PGFS10/PGFS10W
Kompleksowy przewodnik montażu stojaków pod telewizory PERLEGEAR PGFS10 i PGFS10W, zawierający sprawdzenie zgodności, listę części oraz instrukcję krok po kroku z informacjami o środkach ostrożności.
Przedview Instrukcja obsługi stojaka pod telewizor Perlegear PGFS09
Kompleksowa instrukcja obsługi stojaka pod telewizor Perlegear PGFS09, zawierająca szczegółowe informacje na temat montażu, kontroli zgodności i wytycznych bezpieczeństwa dotyczących montażu telewizorów o przekątnej od 32 do 70 cali.