Vertiv GXE3-1000IRT2UXL

Instrukcja obsługi zasilacza UPS Vertiv Liebert GXE3-1000IRT2UXL

Model: GXE3-1000IRT2UXL

1. Wprowadzenie

The Vertiv Liebert GXE UPS is an in-line dual conversion single-phase inverter designed to provide robust power protection for critical IT equipment. This system ensures continuous and reliable power, safeguarding connected devices from various AC sector disruptions through its advanced inline double conversion technology. Its flexible design allows for both rack-mount and tower configurations, making it suitable for diverse application environments.

2. Informacje dotyczące bezpieczeństwa

Please read and understand all safety instructions before installing, operating, or maintaining the UPS. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Koniec produktuview

3.1 Główne cechy

3.2 Przewodnik wizualny

Przód view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration, showing the LCD display and control buttons.
Rycina 3.2.1: Przód View of the UPS. This image displays the front panel of the UPS, highlighting the LCD screen and user interface buttons for status monitoring and configuration.
Tył view of the Vertiv Liebert GXE3-1000IRT2UXL UPS, showing input power, circuit breaker, and eight IEC C13 output receptacles.
Rysunek 3.2.2: Tył View of the UPS. This image shows the back panel, detailing the power input, circuit breaker, and eight IEC C13 output ports for connecting protected devices.
Three-quarter view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration with base stands.
Figure 3.2.3: UPS in Tower Configuration. This perspective view illustrates the UPS standing upright with its included base stands, suitable for tower deployment.
Strona view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration, showing the ventilation grilles.
Rysunek 3.2.4: Strona View of the UPS. This image provides a side profile, highlighting the ventilation grilles essential for proper heat dissipation.

4. Konfiguracja

4.1 Rozpakowanie i kontrola

Carefully unpack the UPS and its accessories. Inspect for any shipping damage. Retain the packaging for future use or return.

4.2 Umieszczenie

Place the UPS in a well-ventilated area, away from direct sunlight, heat sources, and excessive dust or moisture. Ensure sufficient clearance around the unit for proper airflow.

4.3 Configuration (Tower/Rack-Mount)

The GXE3-1000IRT2UXL can be deployed as a tower unit using the included stands or installed in a standard 19-inch rack using an optional rack-mount kit (sold separately). Follow the instructions provided with the rack-mount kit for rack installation.

4.4 Połączenia elektryczne

  1. Moc wejściowa: Connect the UPS input power cord to a grounded electrical outlet. Ensure the outlet provides the correct voltage (230V) i wydajność prądowa.
  2. Urządzenia zewnętrzne: Connect your critical IT equipment (servers, networking devices, etc.) to the IEC C13 output receptacles on the rear of the UPS. Do not overload the UPS beyond its rated capacity (900W).
  3. Porty komunikacyjne: For monitoring and management, connect the appropriate communication cables (USB, RS-232, or optional network card) to your computer or network.

4.5 Początkowe włączenie zasilania

After all connections are secure, press the power button on the front panel to turn on the UPS. The LCD display will illuminate, and the UPS will perform a self-test. Allow the batteries to charge for at least 4 hours before connecting critical loads for optimal runtime.

5. Obsługa UPS-a

5.1 Wyświetlacz LCD i sterowanie

The user-friendly LCD display provides real-time status information, including input/output voltage, load level, battery capacity, and operational mode. Use the navigation buttons next to the LCD to scroll through menus and configure settings.

5.2 tryby pracy

5.3 Zarządzanie oprogramowaniem

For enhanced monitoring and management, install the Vertiv Power Assist software on a connected computer for local control and graceful shutdown. For network-wide management, utilize Vertiv Power Insight or an optional Vertiv Liebert Intellislot IS-UNITY Network Management Card.

6. Konserwacja

6.1 Wymiana baterii

The Vertiv Liebert GXE3-1000IRT2UXL features hot-swappable internal batteries, allowing for replacement without powering down connected equipment. Refer to the detailed battery replacement guide available on the Vertiv support website for specific instructions. Always use genuine Vertiv replacement batteries.

6.2 Czyszczenie

Periodically clean the exterior of the UPS with a soft, dry cloth. Ensure ventilation openings are free from dust and debris to maintain proper airflow and prevent overheating.

6.3 Regularne kontrole

Regularly check the UPS status via the LCD display or management software. Verify that input and output connections are secure and that the UPS is operating in the desired mode.

7. Rozwiązywanie Problemów

This section provides solutions to common issues you may encounter with your UPS. For more complex problems, contact Vertiv technical support.

ProblemMożliwa przyczynaRozwiązanie
UPS nie włącza się.No input power; UPS circuit breaker tripped; Battery deeply discharged.Check power cord connection and wall outlet. Reset the circuit breaker. Allow UPS to charge for several hours.
UPS wydaje ciągły sygnał dźwiękowy.Overload condition; Low battery.Reduce connected load. Allow batteries to recharge.
UPS często przełącza się na tryb akumulatorowy.Niestabilne zasilanie sieciowe; ustawienie czułości jest zbyt wysokie.Check utility power quality. Adjust UPS input sensitivity via LCD or software.

8. Specyfikacje

AtrybutWartość
Numer modeluGXE3-1000IRT2UXL
Wydajność (VA/W)1000VA/900W
Wejście Voltage230 V
Współczynnik mocy wyjściowej0.9
Współczynnik kształtu2U Tower / Rack-Mount Convertible
Gniazda wyjściowe8 x IEC60320 C13
TechnologiaDual Conversion Online
Efficiency (Online Mode)Do 91%
Efficiency (ECO Mode)Do 96%
Czas ładowania< 4 hours to 90% (internal batteries)
Wymiary (pakiet)17.24 x 16.93 x 3.39 cala
Waga przedmiotu35.2 funta
ASINB0DX6YTYFZ
UPC767041034967, 767041034394

9. Gwarancja i wsparcie

The Vertiv Liebert GXE3-1000IRT2UXL UPS comes with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official Vertiv webSzczegółowe warunki gwarancji można znaleźć na naszej stronie.

Wsparcie techniczne

For technical assistance, troubleshooting, or service inquiries, please contact Vertiv customer support. Contact information and support resources can be found on the official Vertiv webstrona: www.vertiv.com/en-us/support/

Powiązane dokumenty - GXE3-1000IRT2UXL

Przedview Vertiv Liebert GXE UPS 1-3kVA Installer/User Guide - Installation and Operation
Comprehensive installer and user guide for the Vertiv Liebert GXE UPS 1-3kVA series, covering installation, operation, maintenance, troubleshooting, and specifications for reliable power protection.
Przedview Vertiv Liebert GXE UPS: Wysokowydajna ochrona zasilania
Poznaj Vertiv Liebert GXE, niezbędny i niedrogi system UPS z podwójną konwersją online, oferujący solidną ochronę zasilania dla aplikacji o mocy od 6000 VA do 10 000 VA. Jego funkcje obejmują wysoką sprawność, elastyczny montaż w szafie rack/wieży, skalowalny czas podtrzymania i zaawansowane zarządzanie.
Przedview Vertiv Liebert GXT5 UPS: Intelligent & Efficient Power Protection | Product Overview
Explore the Vertiv Liebert GXT5 UPS series, offering intelligent and efficient power protection for mission-critical applications. This overview details its features, specifications, family overview, service packages, accessories, and mounting options, highlighting its compact design, high efficiency, and advanced management capabilities.
Przedview Vertiv Liebert HPM: Wysokowydajne rozwiązania chłodzenia centrów danych (4–30 kW)
Poznaj serię Vertiv Liebert HPM, oferującą wydajne i niezawodne rozwiązania klimatyzacyjne dla centrów danych i środowisk krytycznych. Poznaj specyfikacje techniczne, kluczowe funkcje i zastosowania dla wydajności chłodniczej od 4 do 30 kW.
Przedview Liebert NXL UPS Installation Manual: 250-400kVA, 60Hz
This installation manual provides comprehensive instructions for the setup and installation of the Liebert NXL UPS, covering single-module and multi-module units ranging from 250-400kVA at 60Hz. It details safety precautions, mechanical and electrical installation procedures, environmental considerations, and system composition.
Przedview Informacje o wydaniu oprogramowania układowego karty Liebert IntelliSlot Unity w wersji 7.8.0.0
Informacje o wydaniu oprogramowania układowego karty Liebert IntelliSlot Unity w wersji 7.8.0.0, zawierające szczegółowe informacje na temat zgodności, nowych funkcji, aktualizacji zabezpieczeń i znanych problemów.