Vertiv IMD-5M

Vertiv PowerIT IMD-5M Rack PDU Interchangeable Monitoring Device User Manual

Model: IMD-5M

1. Wprowadzenie

The Vertiv PowerIT rPDU IMD-5M is an innovative, hot-swappable Interchangeable Monitoring Device (IMD) designed to enhance power monitoring in data centers. It features a vibrant LCD touchscreen for real-time insights into critical metrics such as power, ampera i tomtage, supporting both local and remote monitoring. The IMD includes ports for serial communication and environmental monitoring, enabling comprehensive management of your power distribution system. Dual Gigabit Ethernet ports facilitate PDU management with fault-tolerant daisy chaining or IP aggregation, providing a reliable and scalable solution for modern IT environments.

This manual provides essential information for the proper installation, operation, and maintenance of your IMD-5M device.

2. Główne cechy

  • Enhanced Data Visualization: Vibrant, pixel-addressable color touchscreen displays key power metrics (amperage, tomtage) for efficient monitoring.
  • Zaawansowane funkcje bezpieczeństwa: Secure boot and hardware trust anchor provide enhanced security against unauthorized access.
  • Effortless Installation and Features: Tool-less installation and removal, redundant power capability, RGB status LED for alerts, and an internal sensor for automatic display orientation adjustment.
  • Tested and Certified for Reliability: 100% tested for quality and functionality, meeting RoHS, China RoHS, UL, and CE compliance standards.
  • Łączność: Serial communication and environmental monitoring ports, dual Gigabit Ethernet for daisy chaining or IP aggregation.

3. Koniec produktuview

Vertiv PowerIT IMD-5M front view with touchscreen displaying power metrics

Rysunek 3.1: Przód view of the Vertiv PowerIT IMD-5M, showing the touchscreen interface and various ports. The screen displays power consumption metrics like wattage and kilowatt-hours.

Vertiv PowerIT IMD-5M angled view showing internal circuitry

Rysunek 3.2: Kątowy view of the IMD-5M, partially revealing the internal circuit board, highlighting its modular and hot-swappable design. The front panel with ports and touchscreen is clearly visible.

Vertiv PowerIT IMD-5M side view showing full internal circuitry

Rysunek 3.3: Strona view of the IMD-5M, providing a clearer look at the entire internal circuitry and its compact form factor, designed for integration into a Rack PDU.

4. Konfiguracja i instalacja

The IMD-5M is designed for tool-less installation and removal into compatible Vertiv PowerIT Rack PDUs. Ensure the PDU is powered off or in a safe state before installation or removal.

  1. Przygotowanie: Verify that the Rack PDU is compatible with the IMD-5M.
  2. Wprowadzenie: Align the IMD-5M with the designated slot on the Rack PDU. Gently push the device into the slot until it clicks securely into place.
  3. Połączenie: Connect necessary network cables to the Gigabit Ethernet ports (1 and 2) for network connectivity and daisy chaining. Connect serial communication or environmental monitoring sensors to their respective ports if required.
  4. Włączanie: Once securely installed and connected, power on the Rack PDU. The IMD-5M will initiate its boot sequence.
  5. Konfiguracja wstępna: Follow the on-screen prompts on the touchscreen for initial network configuration and device settings.

Note: The IMD-5M supports hot-swapping. However, always refer to your specific Rack PDU documentation for best practices regarding module replacement while the PDU is operational.

5. Działanie

5.1. Interfejs dotykowy

The IMD-5M features a vibrant LCD touchscreen for local monitoring and configuration. The internal orientation sensor automatically adjusts the display for optimal viewing, whether the PDU is mounted vertically or horizontally.

  • Główny wyświetlacz: Shows real-time power metrics such as wattage (W), kilowatt-hours (KWh), volt-amperes (VA), and power factor (PF).
  • Nawigacja: Use the on-screen buttons (e.g., "MENU", "BACK") to navigate through different screens and settings.
  • Dioda LED stanu: The RGB status LED provides visual cues for device status and alerts. Refer to the device's online documentation for specific LED color codes.

5.2. Zdalne monitorowanie

The IMD-5M supports remote monitoring and management through its network interfaces. Access the device's web interface or integrate it with your existing data center infrastructure management (DCIM) system.

  • Web Interfejs: Enter the IMD-5M's IP address into a web browser to access its full suite of monitoring and configuration options.
  • SNMP: The device supports SNMP for integration with network management systems.
  • Daisy Chaining/IP Aggregation: Utilize the dual Gigabit Ethernet ports for redundant network connections or to aggregate multiple PDUs under a single IP address, simplifying management.

6. Konserwacja

Regular maintenance ensures the longevity and optimal performance of your IMD-5M.

  • Czyszczenie: Periodically clean the touchscreen and exterior with a soft, dry, anti-static cloth. Do not use abrasive cleaners or solvents.
  • Aktualizacje oprogramowania układowego: Check the Vertiv support website regularly for firmware updates. Keeping the firmware current ensures access to the latest features, security enhancements, and bug fixes.
  • Warunki środowiskowe: Ensure the operating environment adheres to the recommended temperature and humidity ranges specified in the product's technical documentation to prevent overheating or moisture damage.

7. Rozwiązywanie Problemów

This section provides basic troubleshooting steps for common issues. For more complex problems, refer to the Vertiv support webodwiedź witrynę lub skontaktuj się z pomocą techniczną.

ProblemMożliwa przyczynaRozwiązanie
Urządzenie się nie włącza.IMD not fully seated; PDU not powered.Ensure IMD is securely installed. Verify PDU power supply.
Brak połączenia sieciowego.Incorrect cable connection; network configuration error.Check Ethernet cable connections. Verify IP settings on the touchscreen or via serial console.
Ekran dotykowy nie reaguje.Tymczasowy błąd oprogramowania.Perform a soft reset (if available) or power cycle the PDU.

8. Specyfikacje

AtrybutWartość
ModelIMD-5M
Wymiary produktu4 x 1.25 x 2 cala
Waga przedmiotu1 funta
ProducentPionowo
ZgodnośćRoHS, China RoHS, UL, CE
ŁącznośćDual Gigabit Ethernet, Serial, Environmental Monitoring Ports
WyświetlaczVibrant LCD Touchscreen with Internal Orientation Sensor

9. Gwarancja i wsparcie

The Vertiv PowerIT IMD-5M comes with a standard 3-roczna ograniczona gwarancja. Niniejsza gwarancja może zostać rozszerzona na 5 lata by registering your unit within 120 days of purchase.

For technical support, warranty claims, or to register your product, please visit the official Vertiv support website or contact your local Vertiv representative. Keep your purchase receipt and product serial number readily available.

Wsparcie Vertiv Webstrona: www.vertiv.com/support

Powiązane dokumenty - IMD-5M

Przedview Geist™ Intelligent Rack PDU Installer/User Guide - Vertiv
Comprehensive installer and user guide for Vertiv's Geist™ Intelligent Rack PDU, covering installation, setup, network configuration, and advanced features for data center environments.
Przedview Vertiv NetSure Monitor Unit User Manual (UM1M832DNA)
User manual for the Vertiv NetSure Monitor Unit (UM1M832DNA, 1M832DNA, M832DNA), covering operation, configuration, interfaces, and troubleshooting for power distribution monitoring.
Przedview Vertiv SmartRow 2 Infrastructure Solution Installer/User Guide
This comprehensive guide provides detailed instructions for the installation, operation, and maintenance of the Vertiv SmartRow 2 Infrastructure Solution. It covers system overview, features, safety instructions, power management, network configuration, and troubleshooting.
Przedview Instrukcja obsługi Vertiv Liebert XDP z iCOM
Kompleksowa instrukcja obsługi urządzenia Vertiv Liebert XDP z iCOM, szczegółowo opisująca instalację, obsługę, konserwację i rozwiązywanie problemów tego pośredniego systemu chłodzenia dla centrów danych.
Przedview Vertiv VRC Self-Contained Rack Cooler User Manual
User manual for the Vertiv VRC Self-Contained Rack Cooler series (VRC100, VRC101, VRC102B), covering installation, operation, maintenance, and safety guidelines for rack-mounted precision cooling.
Przedview Instrukcja instalacji/użytkownika szafy Vertiv VR: Instalacja, montaż i konserwacja
Kompleksowy podręcznik instalatora i użytkownika systemu szaf Vertiv VR, obejmujący instrukcje bezpieczeństwa, czynności przed instalacją, procedury montażu, montaż, łączenie w szereg, uziemianie i okresową konserwację.