This manual provides detailed instructions for the setup, operation, and maintenance of your AMIR Wireless Indoor Outdoor Thermometer with 3 Remote Sensors. This device is designed to monitor temperature and humidity in various indoor and outdoor environments, providing accurate data for your home, office, or other spaces.

Co jest w pudełku

Notatka: 3 AAA batteries are required for the main unit and 2 AAA batteries for each sensor (not included).

Produkt ponadview

The AMIR Wireless Indoor Outdoor Thermometer system consists of a main display unit and three remote sensors. The main unit displays indoor temperature and humidity, along with readings from the three remote sensors. The remote sensors transmit data wirelessly to the main unit.

Główny wyświetlacz

AMIR Main Display Unit and three remote sensors

Image: The main display unit showing temperature and humidity readings, alongside three remote sensors.

Czujniki zdalne

AMIR Main Display Unit and a single remote sensor with dimensions

Image: The main display unit and one remote sensor, illustrating their compact dimensions.

Organizować coś

1. Instalacja baterii

Ensure you have 3 AAA batteries for the main unit and 2 AAA batteries for each remote sensor (not included).

  1. Główny wyświetlacz: Open the battery compartment on the back of the main unit. Insert 3 AAA batteries, observing the correct polarity (+/-). Close the compartment.
  2. Zdalne czujniki: Open the battery compartment on the back of each remote sensor. Insert 2 AAA batteries into each sensor, observing the correct polarity (+/-). Close the compartment.
Image showing battery installation in the main unit and remote sensors

Image: Illustration of battery compartment and battery insertion for both the main unit and remote sensors.

2. Synchronizacja początkowa

After installing batteries, the main unit will automatically search for signals from the remote sensors. This process may take a few minutes. Ensure all sensors are within range of the main unit during initial setup.

3. Umieszczenie

Place the main unit and remote sensors in desired locations. The wireless transmission range is approximately 100 meters (328 feet) in open air. Walls and other obstructions may reduce this range.

AMIR Main Display Unit on a wall and on a tabletop, with a remote sensor wall-mounted

Obraz: Byłyamples of wall-mount and tabletop placement for the main unit and a remote sensor.

Instrukcja obsługi

1. Wybór jednostki temperatury (℃/℉)

Press the "℃/℉" button on the main unit to switch between Celsius and Fahrenheit temperature display.

2. Max/Min Record Function

The device records the maximum and minimum temperature and humidity values for the main unit and each sensor.

Diagram illustrating Max and Min temperature and humidity tracking over time

Image: A graphical representation of how maximum and minimum temperature and humidity values are recorded.

3. Funkcja podświetlenia

Press the "LIGHT" button on the main unit to activate the backlight. The backlight will automatically turn off after 5 seconds to conserve battery power.

Image of the main unit's backlight button being pressed

Image: A close-up showing the "LIGHT" button on the main display unit.

4. Comfort Level Indicator

The main unit displays a smiley icon to indicate the comfort level based on humidity:

Diagram explaining the comfort level indicators (Dry, Comfortable, Wet) based on humidity percentages

Image: Visual guide to the comfort level icons displayed on the main unit, correlating humidity percentages with "Dry," "Comfortable," and "Wet" conditions.

Konserwacja

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
Brak obrazu na jednostce głównej.Baterie są rozładowane lub nieprawidłowo zainstalowane.Sprawdź biegunowość baterii i wymień je na nowe baterie AAA.
Remote sensor not displaying data.
  • Sensor batteries are dead or incorrectly installed.
  • Czujnik jest poza zasięgiem.
  • Zakłócenia ze strony innych urządzeń elektronicznych.
  • Sensor not properly synchronized.
  • Wymień baterie czujnika.
  • Przesuń czujnik bliżej jednostki głównej.
  • Relocate sensor or main unit away from potential interference sources.
  • Re-insert sensor batteries and press the "CHANNEL" button on the main unit to re-synchronize.
Niedokładne odczyty.
  • Czujnik wystawiony na bezpośrednie działanie promieni słonecznych lub źródła ciepła.
  • Czujnik umieszczono w miejscu o słabej cyrkulacji powietrza.
  • Relocate sensor to a shaded area or away from heat sources.
  • Ensure adequate airflow around the sensor for accurate readings.
MIN/MAX values not resetting as expected.Incorrect mode selected (24hr vs. all-time).Chwila viewing current data (not MAX/MIN), press and hold the "MIN/MAX" button for ~5 seconds to toggle between 24-hour reset and all-time modes.

Specyfikacje

Gwarancja i wsparcie

AMIR products are designed for reliability and performance. For warranty information or technical support, please refer to the contact details provided with your product packaging or visit the official AMIR webStrona. Zachowaj paragon zakupu na wypadek reklamacji.

Powiązane dokumenty - US-WA54

Przedview Instrukcja obsługi termometru do lodówki AMIR
Instrukcja obsługi termometru do lodówki AMIR, szczegółowo opisująca jego funkcje, działanie i specyfikacje dotyczące monitorowania temperatury w lodówkach, zamrażarkach i kuchniach.
Przedview Instrukcja obsługi budzika cyfrowego AMIR – funkcje i obsługa
Kompleksowa instrukcja obsługi budzika cyfrowego AMIR, szczegółowo opisująca jego funkcje, takie jak wyświetlacz LED, wskaźnik temperatury, regulacja jasności, sterowanie głosowe oraz instrukcje dotyczące ustawiania godziny, daty, alarmu i trybu nocnego. Zawiera opcje zasilania i instrukcje obsługi.
Przedview Przenośny sejf AMIR: instrukcje otwierania i rozwiązywanie problemów
Szczegółowy przewodnik otwierania przenośnego sejfu AMIR, w tym rozwiązania problemów związanych z ciśnieniem. Dowiedz się, jak uzyskać dostęp do bezpiecznego schowka, korzystając z instrukcji krok po kroku.
Przedview Instrukcja obsługi budzika radiowego FM
Obszerna instrukcja obsługi budzika z radiem FM, szczegółowo opisująca konfigurację, funkcje takie jak alarm, obsługa radia FM, ustawienia wyświetlacza, tryb weekendowy, ładowanie przez USB, wymianę baterii oraz specyfikację. Zawiera również sekcję rozwiązywania problemów i FAQ.