Wstęp
This manual provides detailed instructions for the setup, operation, and maintenance of your AMIR Wireless Indoor Outdoor Thermometer with 3 Remote Sensors. This device is designed to monitor temperature and humidity in various indoor and outdoor environments, providing accurate data for your home, office, or other spaces.
Co jest w pudełku
- 1 x Main Display Unit (Thermometer)
- 3 x bezprzewodowe czujniki zdalne
- 1 x instrukcja obsługi
Notatka: 3 AAA batteries are required for the main unit and 2 AAA batteries for each sensor (not included).
Produkt ponadview
The AMIR Wireless Indoor Outdoor Thermometer system consists of a main display unit and three remote sensors. The main unit displays indoor temperature and humidity, along with readings from the three remote sensors. The remote sensors transmit data wirelessly to the main unit.
Główny wyświetlacz

Image: The main display unit showing temperature and humidity readings, alongside three remote sensors.
- Duży wyświetlacz LCD: Shows indoor temperature/humidity and data from up to 3 remote sensors simultaneously.
- Funkcja podświetlenia: Dla wyraźnej widoczności w warunkach słabego oświetlenia.
- Pikolak: MIN/MAX, LIGHT, CHANNEL.
- Opcje montażu: Integrated stand for tabletop use and a hang hole for wall mounting.
Czujniki zdalne

Image: The main display unit and one remote sensor, illustrating their compact dimensions.
- Transmisja bezprzewodowa: Sends temperature and humidity data to the main unit.
- Kompaktowa konstrukcja: Suitable for various placements.
- Montowanie: Hang hole for easy placement.
Organizować coś
1. Instalacja baterii
Ensure you have 3 AAA batteries for the main unit and 2 AAA batteries for each remote sensor (not included).
- Główny wyświetlacz: Open the battery compartment on the back of the main unit. Insert 3 AAA batteries, observing the correct polarity (+/-). Close the compartment.
- Zdalne czujniki: Open the battery compartment on the back of each remote sensor. Insert 2 AAA batteries into each sensor, observing the correct polarity (+/-). Close the compartment.

Image: Illustration of battery compartment and battery insertion for both the main unit and remote sensors.
2. Synchronizacja początkowa
After installing batteries, the main unit will automatically search for signals from the remote sensors. This process may take a few minutes. Ensure all sensors are within range of the main unit during initial setup.
- The main unit will display indoor temperature and humidity, along with readings from the connected sensors (Channel 1, 2, 3).
- If a sensor does not connect, try pressing the "CHANNEL" button on the main unit to cycle through channels or re-insert the batteries in the sensor.
3. Umieszczenie
Place the main unit and remote sensors in desired locations. The wireless transmission range is approximately 100 meters (328 feet) in open air. Walls and other obstructions may reduce this range.
- Jednostka główna: Można umieścić na blacie stołu za pomocą zintegrowanej podstawki lub zamontować na ścianie za pomocą otworu do zawieszania.
- Zdalne czujniki: Can be placed outdoors, in a baby room, wine cellar, greenhouse, or any other area where you wish to monitor conditions. Use the hang hole for wall mounting or place on a flat surface.

Obraz: Byłyamples of wall-mount and tabletop placement for the main unit and a remote sensor.
Instrukcja obsługi
1. Wybór jednostki temperatury (℃/℉)
Press the "℃/℉" button on the main unit to switch between Celsius and Fahrenheit temperature display.
2. Max/Min Record Function
The device records the maximum and minimum temperature and humidity values for the main unit and each sensor.
- View Maks./Min.: In normal display mode, press the "MIN/MAX" button once to display the maximum indoor/outdoor temperature and humidity. The screen will show "MAX". Press again to display the minimum indoor/outdoor temperature and humidity. The screen will show "MIN".
- Clear Max/Min: To manually clear today's maximum/minimum values, press and hold the "MIN/MAX" button for approximately 5 seconds while viewzapisywanie rekordów MAX lub MIN.
- Automatyczne resetowanie: The unit may also have an automatic 24-hour reset for MIN/MAX values. To switch between 24-hour reset and all-time (manual reset) modes, hold down the MIN/MAX button for ~5 seconds when the display shows current data (not MAX or MIN). A "24hr" badge will indicate the 24-hour mode.

Image: A graphical representation of how maximum and minimum temperature and humidity values are recorded.
3. Funkcja podświetlenia
Press the "LIGHT" button on the main unit to activate the backlight. The backlight will automatically turn off after 5 seconds to conserve battery power.

Image: A close-up showing the "LIGHT" button on the main display unit.
4. Comfort Level Indicator
The main unit displays a smiley icon to indicate the comfort level based on humidity:
- SUCHY: Wilgotność < 45%
- COM (Comfortable): 45% ≤ Wilgotność ≤ 65%
- MOKRY: Wilgotność > 65%

Image: Visual guide to the comfort level icons displayed on the main unit, correlating humidity percentages with "Dry," "Comfortable," and "Wet" conditions.
Konserwacja
- Czyszczenie: Wytrzyj jednostkę główną i czujniki miękką, miękką szmatką.amp cloth. Do not use abrasive cleaners or immerse the devices in water.
- Wymiana baterii: When a low battery icon appears on the main unit for a specific sensor, it indicates that the batteries in that remote sensor need to be replaced. Replace all batteries in the sensor with new AAA batteries to ensure optimal performance.
- Składowanie: Jeśli urządzenie będzie przechowywane przez dłuższy czas, należy wyjąć wszystkie baterie, aby zapobiec wyciekowi.
Rozwiązywanie problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Brak obrazu na jednostce głównej. | Baterie są rozładowane lub nieprawidłowo zainstalowane. | Sprawdź biegunowość baterii i wymień je na nowe baterie AAA. |
| Remote sensor not displaying data. |
|
|
| Niedokładne odczyty. |
|
|
| MIN/MAX values not resetting as expected. | Incorrect mode selected (24hr vs. all-time). | Chwila viewing current data (not MAX/MIN), press and hold the "MIN/MAX" button for ~5 seconds to toggle between 24-hour reset and all-time modes. |
Specyfikacje
- Numer modelu: US-WA54
- Zakres temperatur wewnętrznych: 0℃ - 60℃ (32℉ - 140℉)
- Zakres temperatury zewnętrznej: -40℃ - 60℃ (-40℉ - 140℉)
- Zakres wilgotności: 10% - 99% wilgotności względnej
- Dokładność temperatury: ± 1 ℃ (± 1.8 ℉)
- Dokładność wilgotności: ±5% wilgotności względnej
- Zasięg transmisji bezprzewodowej: 100m / 328ft (open air)
- Data Update Rate: Co 60 sekund
- Moc jednostki głównej: 3 baterie AAA (brak w zestawie)
- Moc czujnika: 2 x AAA batteries per sensor (not included)
- Typ wyświetlacza: Cyfrowy wyświetlacz LCD z podświetleniem
- Tworzywo: Akrylonitryl-butadien-styren (ABS)
- Wymiary produktu: Main Unit: Approximately 95mm (3.74in) Width x 78mm (3.07in) Height x 20mm (0.79in) Depth; Remote Sensor: Approximately 53mm (2.09in) Width
- Cechy szczególne: Fast Reading System, High Accuracy, Large Display, Low Battery Indicator, Ultra Clear Screen
Gwarancja i wsparcie
AMIR products are designed for reliability and performance. For warranty information or technical support, please refer to the contact details provided with your product packaging or visit the official AMIR webStrona. Zachowaj paragon zakupu na wypadek reklamacji.