GODIYMODULES Mod-CR12V-001

Instrukcja obsługi wielofunkcyjnego cyfrowego przekaźnika czasowego GODIYMODULES DC 12V 0.1s-99h

Model: Mod-CR12V-001

1. Wprowadzenie

This manual provides detailed instructions for the installation, operation, and configuration of the GODIYMODULES DC 12V 0.1s-99h Multifunction Digital Time Delay Relay. This versatile module offers precise timing control for various applications, featuring multiple operating modes and a wide time delay range.

2. Główne cechy

  • Multi-function relay module with 8 distinct operating modes.
  • Adjustable time delay range from 0.1 seconds to 99 hours.
  • Digital display for clear time and mode indication.
  • Operates on DC 12V power supply.
  • Integrated smart relay switch functionality.

3. Specyfikacje

Numer modeluMod-CR12V-001
Wejście VoltagePrąd stały 12 V
Zakres czasu0.1 sekund do 99 godzin
Ocena styku przekaźnika10A 250VAC / 10A 125VAC / 10A 30VDC / 10A 28VDC
WymiaryOkoło 3 x 1.5 x 0.48 cala
WagaOkoło 0.96 uncji

4. Koniec produktuview

The time delay relay module features a compact design with clearly labeled terminals and control buttons. It includes a digital display for time and mode settings, a relay, and input/output terminals.

GODIYMODULES Time Delay Relay Module with labeled components

Rysunek 4.1: Przód view of the time delay relay module with key components labeled. This image shows the digital display, control buttons (SET, ADD, Enter), input terminals (IN, GND, VCC), and relay output terminals (NC, COM, NO).

Z powrotem view of the GODIYMODULES Time Delay Relay Module

Rysunek 4.2: Z powrotem view of the time delay relay module, showing the solder points and circuit board layout.

5. Konfiguracja i okablowanie

Proper wiring is essential for the safe and correct operation of the module. Ensure all connections are secure before applying power.

5.1. Common Wiring Diagram (Shared DC Power Supply)

This diagram illustrates how to connect the module and an equipment load when both share a common DC power supply.

Wiring diagram for DC 12V time delay relay with shared power supply

Rysunek 5.1: Wiring diagram showing the module connected to a DC power supply and an equipment load. DC+ and DC- from the power supply connect to the module's VCC and GND terminals, respectively. The trigger input is connected to the IN terminal. The equipment is connected to the relay's COM and NO (Normally Open) terminals, with the other side of the equipment connected to DC+.

5.2. Module Control AC Load Wiring Diagram

This diagram shows how to use the module to control an AC load, such as a 220V device. Note that the module itself is powered by DC 12V, but its relay can switch AC power.

Wiring diagram for DC 12V time delay relay controlling an AC load

Rysunek 5.2: Wiring diagram for controlling an AC load. The module is powered by DC 12V (DC+ to VCC, DC- to GND). The trigger input connects to IN. The AC load (e.g., 220V equipment) is connected to the relay's COM and NO terminals, with the AC "Fire Wire" connected to one relay terminal and the "Zero Wire" connected to the other side of the equipment.

6. Operating Instructions and Modes

The module offers 8 distinct operating modes, adjustable from 0.1 seconds to 99 hours. Use the control buttons (SET, ADD, Enter) to configure the desired mode and time parameters.

6.1. Setting Time Unit

To select the T1 time unit, press the DODAĆ button. The display will show a value (0/1/2/3). Press DODAĆ again to cycle between the units:

  • 0: Seconds (0.1s - 99.9s)
  • 1: Seconds (1s - 999s)
  • 2: Minutes (1min - 999min)
  • 3: Hours (1h - 99h)

6.2. Wybór trybu pracy

Naciśnij i przytrzymaj USTAWIĆ button for a long time to enter the function selection menu. The display will show P1-P8. Press the USTAWIĆ button briefly to switch between the 8 functions.

6.3. Detailed Mode Descriptions

Detailed descriptions of the 8 operating modes for the time delay relay

Rysunek 6.1: Visual representation of the 8 operating modes (P-1 to P-8) with their respective descriptions and functionalities.

  1. P-1: Delayed Disconnection
    The relay is activated upon power-on. After a delay of T1, the relay disconnects.
  2. P-2: Time-Delayed Absorption (Triggered)
    Upon power-on, the time delay T1 starts. After T1, the relay engages. A low-level signal on the IN terminal will re-trigger this function once.
  3. P-3: Cyclic On/Off (Power-on Start)
    Upon power-on, the relay engages. After delay T1, the relay disconnects. After delay T2, the relay engages. This cycle repeats. The number of cycles can be adjusted from 1 to 99 or set for an infinite cycle.
  4. P-4: Cyclic On-Off (Delay First, Power-on Start)
    Upon power-on, delay T1 starts. After T1, the relay engages. After delay T2, the relay disconnects. This cycle repeats. The number of cycles can be adjusted from 1 to 99 or set for an infinite cycle.
  5. P-5: Trigger Delay Absorption (Repeatable)
    The relay is initially inactive. After a trigger signal, the relay activates. After delay T1, the relay disconnects. A low-level signal on the IN terminal will re-trigger this function. The cycle times can be adjusted from 1 to 99 or set for an infinite cycle.
  6. P-6: Trigger Time-Delay Disconnect
    The relay is initially inactive. Upon triggering, the relay engages. After delay T1, the relay disconnects. A low-level signal on the IN terminal will re-trigger this function once.
  7. P-7: Trigger Cycle On-Off (Repeatable)
    The relay is initially inactive. Upon triggering, the relay engages. After delay T1, it disconnects. After delay T2, it engages. This cycle repeats. The number of cycles can be adjusted from 1 to 99 or set for an infinite cycle.
  8. P-8: Trigger Cycle On/Off (Delayed Start)
    The relay is initially inactive. Upon triggering, delay T1 starts. After T1, the relay engages. After delay T2, the relay disconnects. This cycle repeats. The number of cycles can be adjusted from 1 to 99 or set for an infinite cycle.

7. Konserwacja

The GODIYMODULES Time Delay Relay is designed for reliable operation with minimal maintenance. To ensure longevity and proper function:

  • Utrzymuj moduł w czystości, wolny od kurzu i wilgoci.
  • Unikaj wystawiania modułu na działanie ekstremalnych temperatur i bezpośredniego światła słonecznego.
  • Okresowo sprawdzaj wszystkie połączenia przewodów, aby mieć pewność, że są bezpieczne.
  • Do not attempt to open or modify the module, as this may void any warranty and could lead to malfunction.

8. Rozwiązywanie Problemów

If you encounter issues with your time delay relay module, consider the following common troubleshooting steps:

  • Moduł nie włącza się: Verify that the DC 12V power supply is correctly connected to the VCC and GND terminals and is providing the correct voltage. Check for loose connections or damaged wires.
  • Relay Not Activating/Deactivating:
    • Ensure the correct operating mode (P-1 to P-8) is selected.
    • Check the set time (T1, T2) and time unit.
    • If using a trigger, verify the trigger signal is being applied correctly to the IN terminal.
    • Confirm the load is correctly wired to the relay's COM, NO, or NC terminals.
  • Nieprawidłowy czas: Double-check the set time values and the selected time unit (seconds, minutes, hours).
  • Problemy z wyświetlaniem: If the digital display is blank or showing erratic characters, check the power supply and connections.

Jeśli problemy będą się powtarzać, skontaktuj się z obsługą klienta w celu uzyskania dalszej pomocy.

9. Gwarancja i wsparcie

For warranty information and technical support, please refer to the product packaging or contact GODIYMODULES customer service directly. Keep your purchase receipt as proof of purchase.

Powiązane dokumenty - Mod-CR12V-001

Przedview Rozpoczęcie pracy z Time Timer MOD: Podręcznik użytkownika
Dowiedz się, jak skonfigurować i używać Time Timer MOD. Ten przewodnik obejmuje instalację baterii, preferencje dźwiękowe, ustawienia timera oraz zasady pielęgnacji wizualnego timera.
Przedview Instrukcja obsługi modułów Luminor Blackcomb Equipment: obsługa i instalacja
Niniejsza instrukcja obsługi zawiera szczegółowe instrukcje dotyczące obsługi i instalacji modułów sprzętu Luminor Blackcomb, w tym Emulatora (MOD-EMU), Alarmu zdalnego (MOD-RAM), 4-20 mA (MOD-420), Elektromagnesu (MOD-SOL), Monitora jakości wody SHERPA (MOD-SHERPA) i UV Concierge (MOD-APP).
Przedview Walrus Audio Mako D1 MKII High-Fidelity Stereo Delay Pedal User Manual
Comprehensive guide to the Walrus Audio Mako D1 MKII, a feature-packed, high-fidelity all-in-one stereo delay pedal with six distinct algorithms, controls, presets, and MIDI integration.
Przedview Line 6 DL4 Delay Modeler User Manual
Comprehensive user manual for the Line 6 DL4 Delay Modeler, detailing its features, functions, and operation, including various delay models, loop sampler, and connectivity options.
Przedview Podręcznik instalacji Smappee Infinity: Leitfaden zur Instalacja i konfiguracja systemów zarządzania energią
Dieses Installationshandbuch bietet szczegółlierte Anleitungen zur physischen Instalacja, konfiguracja i zatwierdzanie systemów Smappee Infinity Energiemanagementsystems, das Echtzeit-Energieüberwachung, IoT-Steuerung i Lastausgleich ermöglicht. Für zertifizierte Instalacja.
Przedview Instrukcja instalacji Smappee Infinity
Kompleksowa instrukcja instalacji systemu zarządzania energią Smappee Infinity. Dowiedz się, jak zainstalować, skonfigurować i rozwiązać problemy ze Smappee Infinity, aby zapewnić szczegółowe monitorowanie zużycia energii i sterowanie inteligentnym domem.