ACiQ B0D522DYZ7

Instrukcja obsługi systemu pompy ciepła ACiQ 3 tony 14.4 SEER2 z centralnym inwerterem

Model: B0D522DYZ7

1. Wprowadzenie

This manual provides comprehensive instructions for the installation, operation, and maintenance of your ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System. Please read this manual thoroughly before installation and operation to ensure proper function and safety.

The ACiQ Inverter Heat Pump System is designed for high efficiency heating and cooling, adapting its output to meet changing weather conditions. It includes an inverter heat pump, a multi-positional cased evaporator coil, and a complete installation kit.

2. Informacje dotyczące bezpieczeństwa

Always adhere to local and national electrical and building codes. Installation and servicing should only be performed by qualified personnel.

  • Bezpieczeństwo elektryczne: Disconnect all power before servicing. Ensure proper grounding.
  • Postępowanie z czynnikiem chłodniczym: Only certified technicians should handle refrigerants.
  • Środki ochrony osobistej (PPE): Wear appropriate PPE, including gloves and eye protection, during installation and maintenance.
  • Waga: Components can be heavy. Use proper lifting techniques or seek assistance.

3. Komponenty systemu

The ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Inverter Heat Pump: Converts AC power to DC, adjusting compressor speed and BTU output.
  • Wężownica parownika: Cased multi-positional coil with factory-integrated TXV kit.
  • Zestaw instalacyjny: Includes Cielo Smart Thermostat, 50' insulated line set, 1/2" x 6' 10-gauge electrical whip, 60A non-fused disconnect switch, ICM Controls Surge Protector, CPS Charging Adapter, Wall Sleeve, and Wall Mount Bracket.
ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System components

Rysunek 3.1: Koniecview of the ACiQ Heat Pump System components, including the outdoor unit, indoor coil, thermostat, and various installation accessories.

ACiQ Complete Installation Kit

Rysunek 3.2: Szczegółowy view of the complete installation kit, showing the line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

4. Specyfikacje

4.1. Heat Pump Condenser Specifications

  • Summer Cooling Control: 36,000 BTU/H cooling precision
  • Winter Warmth Control: 36,000 to 35,000 BTU/H heating power
  • Efektywność energetyczna: Up to 14.4 SEER (9.30 EER2) performance
  • Summer Proof Cooling: 5°F to 122°F outdoor temp operation
  • Winter Proof Heating: 5°F to 75°F outdoor temp operation
  • Wężownica skraplacza: Gold fin for durability
  • Działanie: Quietest operation at maximum workloads
Heat Pump Condenser Specifications

Figure 4.1: Visual representation of the heat pump condenser and its key specifications.

4.2. Evaporator Coil Specifications

  • Przepływ powietrza: 1058.82 stopy sześcienne na minutę
  • Ciśnienie: 0.28 In. wg.
  • Osuszanie: 4.64
  • Wymiary (szer. x gł. x wys.): 21.52 x 20.98 x 23.58 cala (547 x 533 x 599 mm)
  • Packing (W x D x H): 23.47 x 26.18 x 25.39 cala (596 x 665 x 645 mm)
  • Masa netto/brutto: 62.19 / 71.00 lbs (28.20 / 32.20 kg)

Note: The coil is specifically designed for use with gas furnaces or modular blowers and cannot be substituted for a one-piece air handler.

Evaporator Coil Specifications

Rysunek 4.2: Szczegółowy view of the evaporator coil with its dimensions and performance metrics.

4.3. Wymiary ogólne

System Measurements

Figure 4.3: Overall dimensions of the outdoor heat pump unit and the evaporator coil.

5. Konfiguracja i instalacja

Installation of this system requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC technician.

5.1. Lista kontrolna przed instalacją

  • Sprawdź, czy wszystkie komponenty są obecne i nieuszkodzone.
  • Ensure proper electrical supply is available (voltage, ampwymazać).
  • Confirm adequate space for both indoor and outdoor units, allowing for proper airflow and service access.
  • Review local building codes and obtain necessary permits.

5.2. Umiejscowienie jednostki zewnętrznej

Place the outdoor unit on a level, stable surface, away from obstructions that could impede airflow. Ensure sufficient clearance around the unit for maintenance and proper operation.

Outdoor Unit Placement Example

Rysunek 5.1: Example of an outdoor unit installed on a wall mount bracket, demonstrating proper clearance.

5.3. Evaporator Coil Installation

The evaporator coil is multi-positional. Install it in conjunction with a gas furnace or modular blower. Ensure proper drainage for condensate.

5.4. Line Set and Electrical Connections

  • Connect the insulated line set between the outdoor unit and the evaporator coil. Ensure proper flaring and torque.
  • Install the electrical whip and disconnect switch according to electrical codes.
  • Connect the ICM Controls Surge Protector for electrical protection.

5.5. Instalacja termostatu

Install the Cielo Smart Thermostat according to its dedicated instructions. This thermostat allows for app control and integration with smart home systems like Alexa, Google Home, Siri, SmartThings, and IFTTT.

Cielo Smart Thermostat Features

Figure 5.2: Diagram illustrating the features and connectivity options of the Cielo Smart Thermostat.

6. Instrukcja obsługi

Once installed, the system can be operated via the Cielo Smart Thermostat or its associated mobile application.

6.1. Podstawowa obsługa

  • Włączanie: Ensure the disconnect switch is in the ON position.
  • Wybór trybu: Use the thermostat to select operating modes: Cooling, Heating, Fan Only, or Auto.
  • Ustawienie temperatury: Dostosuj żądaną temperaturę za pomocą regulatorów termostatu.

6.2. Smart Thermostat Features

The Cielo Smart Thermostat offers advanced features for enhanced comfort and energy savings:

  • Harmonogram: Program daily or weekly schedules to optimize energy use.
  • Dostęp zdalny: Control your system from anywhere using the mobile app.
  • Sterowanie głosowe: Integrate with Amazon Alexa, Google Assistant, or Apple Siri for hands-free control.
  • Integracja inteligentnego domu: Connect with SmartThings and IFTTT for advanced automation.

7. Konserwacja

Regular maintenance is crucial for optimal performance and longevity of your ACiQ system. It is recommended to have a qualified technician perform annual inspections.

7.1. Konserwacja użytkownika

  • Wymiana filtra powietrza: Check and replace air filters monthly or as needed, especially during peak usage seasons.
  • Czyszczenie jednostki zewnętrznej: Keep the area around the outdoor unit clear of debris, leaves, and obstructions. Gently clean the exterior coils with a soft brush and water if necessary.
  • Spust kondensatu: Periodically check the condensate drain line for clogs and ensure proper drainage.

7.2. Profesjonalna konserwacja

An annual professional tune-up typically includes:

  • Refrigerant level check and adjustment.
  • Coil cleaning (indoor and outdoor).
  • Electrical connection inspection and tightening.
  • Blower motor and fan inspection.
  • Thermostat calibration.

8. Rozwiązywanie Problemów

This section provides solutions to common issues. For problems not listed here, or if solutions do not resolve the issue, contact a qualified HVAC technician.

ProblemMożliwa przyczynaRozwiązanie
System się nie włączaNo power, tripped breaker, thermostat issueCheck disconnect switch, reset breaker, ensure thermostat is powered and set correctly.
Niewystarczające ogrzewanie/chłodzenieDirty air filter, blocked outdoor unit, low refrigerant, incorrect thermostat settingReplace air filter, clear obstructions from outdoor unit, check thermostat settings. Contact technician for refrigerant issues.
Nietypowe dźwiękiLuźne części, zablokowany wentylator, problem ze sprężarkąSprawdź, czy panele nie są luźne lub czy nie ma zanieczyszczeń. Jeśli hałas nadal występuje, skontaktuj się z technikiem.
Wyciek wody z jednostki wewnętrznejClogged condensate drain line, frozen evaporator coilClear drain line. If coil is frozen, turn off system and allow to thaw, then check airflow. Contact technician if issue persists.

9. Informacje o gwarancji

The ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System comes with a comprehensive warranty:

  • Strony: 7 rok gwarancji na części.
  • Kompresor: 12 lat gwarancji na kompresor.

Warunki gwarancji: The warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records.

10. Wsparcie i kontakt

For technical support, warranty claims, or service inquiries, please contact ACiQ customer service or visit our official webstrona.

ACiQ Official Webstrona: Visit the ACiQ Store on Amazon

Please have your model number (B0D522DYZ7) and purchase date ready when contacting support.

Powiązane dokumenty - B0D522DYZ7

Przedview Instrukcja instalacji systemów ACiQ Central Inverter
Kompleksowa instrukcja instalacji centralnych inwerterowych systemów klimatyzacji i pomp ciepła ACiQ, szczegółowo opisująca środki ostrożności, rury chłodnicze, instalację jednostki zewnętrznej, okablowanie, specyfikacje zasilania, odprowadzanie powietrza i procedury testowe.
Przedview Szybki przewodnik po systemie pompy ciepła ACiQ o wysokiej wydajności: seria Standard i Extreme z czynnikiem chłodniczym R-454B
Skrócona instrukcja instalacji i podłączania wysokowydajnych pomp ciepła ACiQ (seria Standard i Extreme z czynnikiem chłodniczym R-454B). Obejmuje okablowanie termostatu, ustawienia przełączników DIP oraz podstawową konfigurację dla różnych scenariuszy instalacji.
Przedview Instrukcja montażu jednostki zewnętrznej ACiQ Central Inverter Systems
Kompleksowa instrukcja instalacji jednostek zewnętrznych ACiQ Central Inverter Systems, obejmująca środki ostrożności, rury chłodnicze, okablowanie, instalację jednostki i procedury testowe dla modeli takich jak ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB i innych.
Przedview System pompy ciepła ACiQ Next Gen z kanałami: Skrócona instrukcja obsługi okablowania termostatu
Niniejszy przewodnik zawiera podstawowe informacje dotyczące podłączania i okablowania termostatów do systemu pompy ciepła ACiQ Next Gen Ducted. Szczegółowo opisuje zalecane i alternatywne opcje połączeń, w tym ustawienia przełączników DIP i konfiguracje listew zaciskowych dla różnych typów termostatów.
Przedview Instrukcja obsługi i instrukcja obsługi centralnego systemu grzewczego ACiQ Central Heat Pump Split
Kompleksowa instrukcja obsługi systemów ACiQ Central Heat Pump Split, obejmująca środki ostrożności, warunki pracy, funkcje, wskazówki dotyczące oszczędzania energii, konserwację i rozwiązywanie problemów dla modeli ACiQ-24, ACiQ-36 i ACiQ-48.
Przedview Instrukcja montażu jednostki zewnętrznej ACiQ Central Inverter Systems
Kompleksowa instrukcja instalacji jednostek zewnętrznych ACiQ Central Inverter Systems, obejmująca środki bezpieczeństwa, przewody czynnika chłodniczego, instalację jednostki zewnętrznej, okablowanie, parametry zasilania, odpowietrzanie i procedury testowe. Zawiera szczegółowe informacje o modelu i ważne uwagi dotyczące prawidłowej konfiguracji.