1. Wprowadzenie
This manual provides essential information for the safe and efficient operation of your BITMAIN Antminer S19 86TH/S Bitcoin ASIC Miner. Please read this document thoroughly before setting up and operating the device. Proper installation and maintenance are crucial for optimal performance and longevity.
The Antminer S19 is designed for high-performance cryptocurrency mining using the SHA256 algorithm, supporting currencies such as Bitcoin (BTC), Bitcoin Cash (BCH), and Bitcoin SV (BSV). It features an air-cooling system and is optimized for energy efficiency.
2. Konfiguracja
2.1. Rozpakowanie i inspekcja
Carefully remove the Antminer S19 from its packaging. Inspect the device for any visible damage that may have occurred during transit. Ensure all components are present.

Rycina 1: Przód view of the Antminer S19.

Figure 2: Multiple Antminer S19 units, illustrating their compact design.
2.2. Podłączenie zasilania
The Antminer S19 requires a 200-240V AC input voltage. A power cord is NIE ZAWIERA with the unit. Use an appropriate power cord and ensure the voltage supply is within the specified range. Incorrect voltage can cause severe damage to the miner.
Figure 3: Rear panel of the Antminer S19, highlighting power input ports and the RJ45 Ethernet port.
2.3. Połączenie sieciowe
Podłącz górnika do swojej sieci za pomocą Kabel Ethernet RJ45. The device supports 10/100M Ethernet connections. Ensure a stable internet connection for continuous mining operations.
2.4. Wstępna konfiguracja
Once powered on and connected to the network, the miner will typically acquire an IP address via DHCP. Access the miner's web interface using its IP address to configure mining pool settings, worker names, and other parameters. Refer to the BITMAIN official website for detailed software configuration guides.
3. Operating the Antminer S19
3.1. Wydajność w porównaniuview
The Antminer S19 delivers a hashrate of 86 TH/S ± 3%, with a power efficiency of 34.5 J/TH ± 5%. It operates on approximately 2967W ± 5% at 77°F (25°C) ambient temperature. These figures are crucial for calculating potential profitability and ensuring your electrical infrastructure can support the load.
3.2. Wymagania środowiskowe
To ensure stable and long-term operation, adhere to the following environmental conditions:
- Temperatura pracy: od 32°F do 113°F (od 0°C do 45°C)
- Temperatura przechowywania: -4°F do 158°F (-20°C do 70°C)
- Wilgotność robocza (bez kondensacji): Wilgotność względna od 10% do 90%
- Wysokość operacji: ≤ 2000 metrów
Operating outside these ranges may lead to reduced performance, instability, or permanent damage to the unit.
4. Konserwacja
4.1. Air Filter and Fan Cleaning
The Antminer S19 utilizes an air-cooling system. Regular cleaning of the air intake and exhaust fans is essential to prevent dust buildup, which can impede airflow and lead to overheating. Use compressed air to gently clear dust from the fan blades and heatsinks. Ensure the device is powered off and disconnected from the power source before performing any cleaning.
Rycina 4: Przód view of the Antminer S19, highlighting the air-cooling fans.
4.2. Monitorowanie środowiska
Continuously monitor the operating temperature and humidity of the mining environment. Maintaining optimal conditions will extend the lifespan of your miner and ensure consistent performance.
5. Rozwiązywanie Problemów
5.1. Typowe problemy
- Brak zasilania: Verify the power cord is securely connected and the power supply is receiving adequate voltage (200-240 V).
- Brak połączenia sieciowego: Check the Ethernet cable connection and ensure your network is operational. Confirm the miner has obtained an IP address.
- Niski współczynnik hashowania: This can be caused by poor network connectivity, incorrect mining pool settings, or environmental factors such as high temperatures.
- Przegrzanie: Ensure proper ventilation and clean the fans. Check ambient room temperature.
5.2. Important Note on Voltage
Użycie nieprawidłowej objętości wejściowejtage (e.g., 110V instead of 220-240V) will likely cause irreversible damage to the miner. Always confirm your power source meets the specified requirements before connecting the device.
6. Specyfikacje
| Funkcja | Specyfikacja |
|---|---|
| Model | S19 |
| Algorytm | Kryptowaluta | SHA256 | BTC/BCH/BSV |
| Hashrate | 86 TH/S ± 3% |
| Zasilanie ścienne w temperaturze 77°F (25°C) | 2967W ± 5% |
| Wydajność energetyczna na ścianie w temperaturze 25°C (77°F) | 34.5 J/TH ± 5% |
| Zasilanie AC Wejście voltage | 200~240 V |
| Zakres częstotliwości wejściowej prądu przemiennego zasilania | 47~63 Hz |
| Zasilanie AC Prąd wejściowy | 20 Amp |
| Tryb połączenia sieciowego | RJ45 Ethernet 10/100M |
| Rozmiar górnika (długość*szerokość*wysokość, bez opakowania) | 15.75 x 7.68 x 11.42 cala |
| Miner Size (Length*Width*Height, with package) | 22.45 x 12.45 x 16.93 cala |
| Masa netto | 33.96 funtów |
| Masa brutto | 37.92 funtów |
| Temperatura pracy | 32~113°F (0~45°C) |
| Temperatura przechowywania | -4~158°F (-20~70°C) |
| Wilgotność robocza (bez kondensacji) | 10~90% wilgotności względnej |
| Wysokość pracy | ≤2000m |
7. Gwarancja i wsparcie
7.1. Zakres gwarancji
Brand new BITMAIN Antminer units are covered by a warranty provided directly by BITMAIN. The seller is not responsible for warranty claims. Customers are required to contact BITMAIN's official website for warranty service and support. Dedicated personnel at BITMAIN will assist you with any warranty-related inquiries.
7.2. Zasady zwrotu
For brand new BITMAIN Antminer units, if a return is not due to product malfunction, a 40% restocking fee will be applied. Please consider your purchase carefully before proceeding.
7.3. Wsparcie techniczne
For technical assistance, troubleshooting beyond this manual, or any operational questions, please refer to the official BITMAIN support channels. Their website typically provides comprehensive FAQs, forums, and direct contact options for technical support.