ACiQ RXNG09AXVJU / FTXNG09AXVJU

Instrukcja obsługi systemu klimatyzacji/ogrzewania Goodman Mini-Split E-Series

Model: RXNG09AXVJU / FTXNG09AXVJU | Brand: ACiQ

Wstęp

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Goodman Mini-Split AC/Heating System E-Series. Please read this manual thoroughly before installation and use, and retain it for future reference. This system is designed to provide efficient heating and cooling for residential and light commercial applications.

Konfiguracja i instalacja

The Goodman Mini-Split AC/Heating System E-Series includes an indoor wall-mounted air handler unit, an outdoor mini-split heat pump condenser, and a comprehensive installation kit. Professional installation is recommended for optimal performance and safety.

Zawiera elementy

Goodman Mini-Split AC/Heating System E-Series with all components

Rysunek 1: Koniecview of the Goodman Mini-Split AC/Heating System E-Series and its included components, showing the indoor unit, outdoor unit, remote control, and installation kit elements.

Zagadnienia instalacyjne

Ensure the installation area for both indoor and outdoor units meets the required clearances for proper airflow and maintenance. The system operates on 208/230V, 1 Phase, 60Hz power. The 0.75-ton unit is designed to efficiently heat and cool areas up to 400 square feet.

ACiQ Mini Split Installation Kit components

Rysunek 2: Szczegółowy view of the ACiQ Mini Split Installation Kit, including line sets, control wire, drain tube, wall mount bracket, and line cover guards.

Instrukcja obsługi

Your Goodman E-Series Mini-Split system offers various modes and features for optimal comfort and energy efficiency.

Podstawowe tryby działania

Główne funkcje i sterowanie

Goodman E-Series Mini-Split features list

Figure 3: Illustration of the key features of the Goodman E-Series Mini-Split system, including remote control, auto-restart, self-diagnosis, and various operational modes.

Konserwacja

Regular maintenance ensures the longevity and efficient operation of your mini-split system. Always disconnect power to the unit before performing any maintenance.

Czyszczenie filtra

The system is equipped with a Catechin Air Quality Filter System and a Titanium Apatite Deodorising Filter. These filters should be cleaned regularly, typically every 2-4 weeks depending on usage and air quality. Refer to the specific instructions in your full product manual for filter removal and cleaning procedures. Generally, filters can be gently vacuumed or washed with lukewarm water and mild detergent, then air-dried completely before reinstallation.

Drain Pan Maintenance

The indoor unit features a removable dirt-water drain pan. Periodically inspect and clean the drain pan to prevent mold growth and blockages, which can lead to water leaks. Ensure the drain tube is clear and free of obstructions.

Czyszczenie jednostki

The indoor unit has a wipe-clean flat panel. Use a soft, damp cloth to clean the exterior surfaces. Do not use harsh chemicals or abrasive cleaners. For the outdoor unit, ensure the coils are free of debris and obstructions. The outdoor unit also features anti-corrosion treatment for enhanced durability.

Rozwiązywanie problemów

Before contacting customer support, please refer to the following common issues and solutions. The self-diagnosis feature with a digital display can provide initial indications of problems.

ProblemMożliwa przyczynaRozwiązanie
Jednostka się nie włączaNo power, remote control batteries low, unit switch off.Check power supply, replace remote batteries, ensure indoor unit ON/OFF switch is engaged.
Niewystarczające ogrzewanie/chłodzenieBrudne filtry powietrza, zablokowana jednostka zewnętrzna, nieprawidłowe ustawienie trybu/temperatury, wyciek czynnika chłodniczego.Clean filters, clear obstructions from outdoor unit, verify settings, contact professional for refrigerant check.
Niezwykły hałasLuźne części, zablokowany wentylator, hałas przepływu czynnika chłodniczego (normalne).Inspect for loose parts or obstructions. If noise persists or is abnormal, contact service.
Wyciek wody z jednostki wewnętrznejClogged drain pan/tube, improper installation.Clean drain pan and tube. If issue persists, professional inspection is required.
Cyfrowy wyświetlacz pokazuje kod błęduWewnętrzny błąd systemu.Note the error code and consult the full product manual or contact customer support for specific guidance.

For issues not listed or if troubleshooting steps do not resolve the problem, please contact a qualified HVAC technician or ACiQ customer support.

Specyfikacje

Detailed technical specifications for the Goodman Mini-Split AC/Heating System E-Series (0.75 Ton, 9000 BTU).

AtrybutWartość
Nazwa markiACiQ
Informacje o modeluRXNG09AXVJU / FTXNG09AXVJU
BTU Capacity (Cooling)9,000 BTU (0.75 tony)
BTU Capacity (Heating)4,400 BTU – 13,000 BTU
SEER2 Efficiency18 SEER2
Tomtage208/230 Volts, 1 Phase, 60Hz
Poziom hałasu (jednostka zewnętrzna)56dB
Typ instalacjiSystem dzielony
Współczynnik kształtuMini-split
ChłodziwoR410A
Zalecany obszar zasięguDo 400 stóp kwadratowych
Goodman Mini-Split AC/Heating System dimensions and specifications

Figure 4: Dimensional specifications and performance ratings for the Goodman Mini-Split AC/Heating System, including BTU, square footage coverage, and noise levels.

Gwarancja i wsparcie

For warranty information, please refer to the warranty card included with your product or visit the official ACiQ website. Warranty terms typically cover manufacturing defects and vary by component.

For technical support, service requests, or to inquire about replacement parts, please contact ACiQ customer service. Have your model number (RXNG09AXVJU / FTXNG09AXVJU) and purchase date ready when contacting support.

Zasoby internetowe: For additional resources, FAQs, and product registration, visit the ACiQ Store on Amazon.

Powiązane dokumenty - RXNG09AXVJU / FTXNG09AXVJU

Przedview ACiQ Standard Single-Zone Mini Split Installation and Owner's Manual
Comprehensive guide for installing and operating ACiQ Standard Single-Zone Mini Split air conditioning systems. Covers safety precautions, unit specifications, installation procedures, maintenance, and troubleshooting.
Przedview ACiQ 9K-24K Standardowe systemy grzewcze jednostrefowe: Instalacja i instrukcja obsługi
Instrukcja instalacji i obsługi klimatyzatorów ACiQ 9K-24K Standard Heat Single-Zone. W tym przewodniku szczegółowo opisano instalację, obsługę, bezpieczeństwo i konserwację klimatyzatorów ACiQ, w tym specyfikację modelu i informacje o czynniku chłodniczym R454B.
Przedview ACiQ R32 Multi-Zone Condenser & Wall Mounted Air Handler Troubleshooting Guide
This troubleshooting guide provides detailed steps and solutions for common faults and errors encountered with ACiQ R32 Multi-Zone Condenser and Wall Mounted Air Handler systems, including sensor faults, communication errors, and component issues.
Przedview ACiQ 9K-24K Standardowe systemy grzewcze jednostrefowe: Instalacja i instrukcja obsługi
Kompleksowa instrukcja instalacji i obsługi jednostrefowych systemów grzewczych ACiQ 9K-24K Standard Heat, obejmująca konfigurację, obsługę, konserwację i rozwiązywanie problemów dla różnych modeli ACiQ.
Przedview Instalacja i instrukcja obsługi ściennego urządzenia do przetwarzania powietrza ACiQ i jednostrefowego skraplacza Extreme Heat
W niniejszej instrukcji znajdują się szczegółowe wytyczne dotyczące instalacji, obsługi i bezpieczeństwa montowanych na ścianie urządzeń klimatyzacyjnych ACiQ oraz jednostrefowych skraplaczy odpornych na wysokie temperatury, obejmujących modele od ACIQ-06W-HH-MD do ACIQ-24ZPL-HP230C.
Przedview ACiQ R32 Multi-Zone Condenser & Wall Mounted Air Handler Service & Technical Manual
Comprehensive service and technical manual for ACiQ R32 Multi-Zone Condenser and Wall Mounted Air Handler units. This guide provides detailed information on installation, operation, troubleshooting, and maintenance for models ACiQ-09W-E-M, ACiQ-12W-E-M, ACiQ-18W-E-M, ACiQ-18Z-E-M2, and ACiQ-24Z-E-M3.