ELKO EL-430

ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

Instrukcja obsługi

Wstęp

This manual provides detailed instructions for the proper use, setup, and maintenance of your ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer. Please read this manual thoroughly before using the device to ensure accurate readings and safe operation. This device is designed for professional and home use to measure blood pressure non-invasively.

Co jest w pudełku

ELKO EL-430 Sphygmomanometer components and packaging

Image showing the ELKO EL-430 Sphygmomanometer packaging and its main components: the high precision gauge, BP bulb with valve, and special design cotton cuff.

Upon opening the package, verify that all components are present and undamaged. The standard package for the ELKO EL-430 includes:

Główne cechy

ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

Image of the ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer, showing the large clock-face gauge, the black cotton cuff, and the inflation bulb.

Organizować coś

Before taking a measurement, ensure the device is properly assembled and positioned. The EL-430 is a clock/desk type unit, designed for stable placement during use.

  1. Rozpakuj komponenty: Carefully remove the sphygmomanometer, cuff, and inflation bulb from the packaging.
  2. Connect Cuff and Bulb: Ensure the cuff and inflation bulb are securely connected to the gauge via their respective tubes. The dual-tube bladder should be correctly attached.
  3. Pozycja urządzenia: Place the main gauge unit on a stable, flat surface, such as a desk or table, at approximately heart level. The integrated basket can be used to keep the cuff and bulb organized.
  4. Przygotowanie pacjenta: The patient should be seated comfortably with their arm resting on a flat surface, palm facing upwards. Ensure the arm is relaxed and at heart level. Avoid talking or moving during the measurement.

Operating Instructions: Measurement Procedures

Blood Pressure Measurement Procedures

Image illustrating the four key steps for blood pressure measurement: stethoscope placement, cuff inflation, listening for Korotkoff sounds, and controlled deflation.

Aby uzyskać dokładny pomiar ciśnienia krwi, wykonaj następujące kroki:

  1. Cuff Placement and Stethoscope Positioning: Wrap the cuff firmly around the upper arm, ensuring it is snug but not too tight. The lower edge of the cuff should be about 1 inch (2-3 cm) above the elbow joint. Place the stethoscope head over the main artery (brachial artery), which is typically found on the inner side of the arm, underneath the artery mark of the cuff.
  2. Inflacja: With the air release valve completely closed, press the inflation bulb repeatedly and continue pumping until the gauge reads a value 20-30 mmHg above your normal systolic blood pressure. If you do not know your normal systolic pressure, inflate to approximately 180-200 mmHg.
  3. Listening and Recording Systolic Pressure: Slowly open the air release valve to deflate the cuff at a rate of 2-3 mmHg per second. Listen carefully through the stethoscope. The first distinct, rhythmic sound you hear (Korotkoff sound) indicates the systolic pressure (the upper number). Note the reading on the gauge at this exact moment.
  4. Listening and Recording Diastolic Pressure: Continue to slowly deflate the cuff. The point at which the Korotkoff sounds completely disappear indicates the ciśnienie rozkurczowe (the lower number). Note this reading on the gauge. If the sounds become muffled but do not disappear, the muffled sound point can be considered the diastolic pressure.

Zrozumienie odczytów ciśnienia krwi

Blood Pressure Chart and Reading Precautions

Image displaying a blood pressure chart categorizing readings (Normal, Elevated, High Blood Pressure Stages 1 & 2, Hypertensive Crisis) and a list of conditions under which a reading should not be attempted.

Refer to the chart below for general blood pressure categories. Consult a healthcare professional for interpretation of your readings and personalized advice.

Blood Pressure Chart (mmHg)
Kategoria ciśnienia krwiSystolic (upper number)Diastolic (lower number)
NormalnaMniej niż 120Mniej niż 80
Podniesiony120-129Mniej niż 80
Wysokie ciśnienie krwi (nadciśnienie) Stage1130-13980-89
Wysokie ciśnienie krwi (nadciśnienie) Stage2140 lub wyższy90 lub wyższy
Hypertensive Crisis (consult your doctor immediately)Powyżej 180Powyżej 120

DO NOT ATTEMPT A READING...

  1. Within 1 hour of food intake.
  2. Immediately after a tea, coffee, or a smoke.
  3. Within 20 minutes of taking a bath.
  4. While talking or moving your hand/fingers.
  5. When climate is very cold.
  6. When bladder is full or you feel like discharging urine.

Konserwacja i pielęgnacja

Proper maintenance ensures the longevity and accuracy of your sphygmomanometer.

Rozwiązywanie problemów

If you encounter issues with your ELKO EL-430, refer to the following common problems and solutions:

Specyfikacje

SpecyfikacjaSzczegół
Numer modeluEL-430
Typ wyświetlaczaAnalog
Zakres pomiaru0 - 300 mmHg
Dokładność+/- 3 mmHg
Rodzaj mankietuLarge Cotton Cuff with Velcro Fasteners
Zawarte komponentyCuff, Gauge, Inflation Bulb with Valve
Waga przedmiotu600 gramów
Wymiary produktu (dł. x szer. x wys.)14L x 14W x 18Th Centimeters
ProducentAnita Industries
Kraj pochodzeniaIndie
Data pierwszej dostępności12 lutego 2024

Gwarancja i wsparcie

For warranty information, technical support, or service inquiries regarding your ELKO EL-430 Sphygmomanometer, please contact the manufacturer directly.

Dane kontaktowe producenta:
Anita Industries
New Delhi, India
E-mail: info@elkoindia.com
Telefon: +91 9911129201

Please have your model number (EL-430) and date of purchase available when contacting support.

Powiązane dokumenty - EL-430

Przedview Instrukcja obsługi i utylizacji gniazda TV/SAT/R ELKO RS16
Kompleksowy przewodnik dotyczący utylizacji i recyklingu gniazda TV/SAT/R ELKO RS16, zawierający szczegółowe informacje o produkcie, informacje o komponentach i możliwości recyklingu zgodnie z dyrektywą WEEE.
Przedview Instrukcja obsługi inteligentnego termostatu grzejnikowego ELKO
Kompleksowy podręcznik użytkownika inteligentnego termostatu grzejnikowego ELKO, obejmujący uruchomienie, konfigurację, użytkowanie, rozwiązywanie problemów oraz specyfikację techniczną. Dowiedz się, jak sparować, sterować i automatyzować system ogrzewania, aby zapewnić komfort i efektywność energetyczną.
Przedview ELKO Schuko Socket Outlet with USB 3.0 A Charger - Installation and User Guide
Comprehensive guide for the ELKO Schuko socket outlet featuring dual USB 3.0 A charging ports (Type A and Type C). Includes essential safety warnings, detailed technical specifications, installation steps, and usage instructions for electrical professionals and end-users.
Przedview Instrukcja montażu gniazdka ściennego ELKO Plus / ELKO RS16 DCL
Kompleksowy przewodnik instalacji gniazd ściennych ELKO Plus i ELKO RS16 DCL. Zawiera kluczowe ostrzeżenia dotyczące bezpieczeństwa, instrukcje montażu krok po kroku, demontaż pokrywy, podłączanie wtyczek, specyfikacje techniczne oraz informacje dotyczące prawidłowej utylizacji. Niezbędny dla wykwalifikowanych elektryków.
Przedview Instrukcja obsługi inteligentnego termostatu grzejnikowego ELKO – instalacja, konfiguracja i obsługa
Kompleksowy podręcznik użytkownika inteligentnego termostatu grzejnikowego ELKO (EKO09765), obejmujący instalację, parowanie, konfigurację, codzienne użytkowanie, harmonogramowanie, automatyzację, rozwiązywanie problemów i specyfikacje techniczne.
Przedview ELKO Inteligentny termostat grzejnikowy Brukerhåndbok
Detaljert brukerhåndbok dla ELKO Smart Radiatortermostat, som dekker oppsett, bruk, paring, automasjon, feilsøking i tekniske spesifikasjoner dla optymalnego ogrzewania.