1. Koniec produktuview
The OMTech CW-5200 Industrial Water Chiller is designed to provide efficient and stable cooling for CO2 laser engraving and cutting machines. It features a 6-liter water tank, a 0.9 HP compressor, and a cooling capacity of 5186 BTU/hour, ensuring optimal performance for laser tubes up to 150W. This manual provides essential information for safe operation, setup, maintenance, and troubleshooting.

Figure 1: OMTech CW-5200 Industrial Water Chiller, front-side view.

Figure 2: The CW-5200 Water Chiller in operation with a laser engraver.
2. Instrukcje bezpieczeństwa
Read all safety warnings and instructions carefully before operating the chiller. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Upewnij się, że chłodziarka jest umieszczona na stabilnej i równej powierzchni.
- Connect the chiller to a properly grounded power outlet.
- Nie należy używać chłodziarki, jeśli przewód zasilający lub wtyczka są uszkodzone.
- Keep the chiller away from heat sources, flammable materials, and direct sunlight.
- Ensure adequate ventilation around the chiller to prevent overheating.
- Do not immerse the chiller in water or other liquids.
- Use only distilled water or recommended laser coolant. Do not add tap water directly.
- Always disconnect power before performing any maintenance or refilling the water tank.
- Keep children and unauthorized personnel away from the operating chiller.
3. Składniki produktu
Familiarize yourself with the main components of your CW-5200 water chiller.

Rysunek 3: Funkcje panelu przedniego
1. Wyłącznik zasilania
2. Wyświetlacz temperatury
3. Built-in Handles

Rysunek 4: Cechy tylnego panelu
1. Port wtrysku wody
2. Power Socket (with Spare Fuse)
3. Alarm Output Terminal
4. Cooling Water Outlet
5. Cooling Water Inlet
6. Water Level Gauge
7. Radiator Fans
8. Odpływ wody

Figure 5: High-grade brass inlet and outlet ports for secure connections.
4. Instrukcje konfiguracji
Follow these steps for initial setup of your water chiller.
- Rozpakowywanie: Carefully remove the chiller from its packaging. Inspect for any damage during transit.
- Umieszczenie: Place the chiller on a flat, stable surface in a well-ventilated area. Ensure there is at least 20 cm (8 inches) of space around the unit for proper airflow.
- Napełnij zbiornik na wodę: Unscrew the water injection port cap (1 in Figure 4). Fill the tank with approximately 6 liters (1.6 gallons) of distilled water or OMTech laser coolant. Monitor the water level gauge (6 in Figure 4) to ensure the level is within the green zone. Do not overfill.
- Podłącz węże wodne: Connect the water inlet of your laser machine to the Cooling Water Outlet (4 in Figure 4) of the chiller. Connect the water outlet of your laser machine to the Cooling Water Inlet (5 in Figure 4) of the chiller. Secure all connections to prevent leaks.
- Podłączenie zasilania: Connect the power cord to the Power Socket (2 in Figure 4) on the chiller and then plug it into a grounded electrical outlet.

Figure 6: Use of OMTech Laser Coolant for optimal performance.

Figure 7: The 6L enclosed water tank design.
5. Instrukcja obsługi
Operating the CW-5200 chiller is straightforward once properly set up.
- Włączanie: Flip the Power Switch (1 in Figure 3) to the 'ON' position. The chiller will start, and the temperature display will illuminate.
- Initial Circulation: Allow the chiller to run for a few minutes to circulate the water and remove any air bubbles from the system. Check the water level gauge again and add more water if necessary.
- Monitorowanie temperatury: The digital display (2 in Figure 3) shows the current water temperature. The chiller is designed to maintain the water temperature within 0.3°C of the set point.
- Działanie lasera: Once the chiller has reached a stable operating temperature, you can begin operating your CO2 laser machine. The chiller will automatically regulate the water temperature to prevent overheating of the laser tube.
- Wyłączone: After use, turn off your laser machine first, then switch off the chiller using the Power Switch.

Figure 8: Real-time temperature display for precise monitoring.

Figure 9: Digital display and indicators provide real-time feedback.
6. Konserwacja
Regular maintenance ensures the longevity and optimal performance of your chiller.
- Wymiana wody: Replace the cooling water every 1 to 3 months, depending on usage and environmental conditions. Always use distilled water or OMTech laser coolant.
- Czyszczenie żeberek chłodnicy: Periodically clean the radiator fins (7 in Figure 4) to ensure efficient heat dissipation. Use a soft brush or compressed air to remove dust and debris.
- Sprawdź poziom wody: Regularly check the water level gauge and refill if the level drops below the green zone.
- Drenaż: Use the water drain port (8 in Figure 4) to empty the tank when replacing water or storing the unit.
- Sprawdź węże: Periodically inspect all water hoses for kinks, cracks, or leaks. Replace any damaged hoses immediately.

Figure 10: Quick drainage system for easy water removal.
7. Rozwiązywanie Problemów
This section addresses common issues you might encounter with your CW-5200 chiller.
- Chiller Not Turning On:
- Check if the power cord is securely plugged into both the chiller and the wall outlet.
- Sprawdź, czy wyłącznik zasilania jest w pozycji „ON”.
- Check the fuse in the power socket (2 in Figure 4). Replace if blown.
- Woda nie krąży:
- Ensure the water level is adequate.
- Check for kinks or blockages in the water hoses.
- Verify that the pump is operating (listen for pump noise).
- Alarm wysokiej temperatury wody:
- Ensure the chiller's radiator fins are clean and not obstructed.
- Verify that the ambient room temperature is not excessively high.
- Check if the cooling fans are operating.
- Upewnij się, że poziom wody jest odpowiedni.
- Wyciek wody:
- Inspect all hose connections for tightness.
- Check hoses for any damage or cracks.
If issues persist, contact OMTech customer support for assistance.
8. Specyfikacje
Detailed technical specifications for the OMTech CW-5200 Water Chiller.

Figure 11: Key specifications of the CW-5200 Chiller.
| Funkcja | Specyfikacja |
|---|---|
| Model | CW-5200 |
| Tworzywo | Steel, ABS, Copper |
| Moc sprężarki | 680W (0.9KM) |
| Pojemność zbiornika | 6 litra (1.6 galona) |
| Maksymalny udźwig | Ft. 29.5 (9 m) |
| Max. Przepływ | 2.6 gal./min. (10 L/min.) |
| Wydajność chłodzenia | 5186 BTU/godz. |
| Temperature Control Precision | ±0.3℃ |
| Funkcje ochronne | High Current, Low Water Flows, High Water Temps |
| Wymiary produktu | 22" gł. x 11.4" szer. x 17" wys. |
| Waga | 57.3 funtów |
| Źródło zasilania | Elektryczny przewodowy |
9. Gwarancja i wsparcie
OMTech provides comprehensive support for its products.
- Gwarancja: Ten produkt jest objęty roczną gwarancją. Szczegółowe warunki i postanowienia znajdują się w dokumentacji zakupu.
- Obsługa klienta: Our 24/7 global support team is available to provide expert assistance, including technical guidance.
- Kontakt: For support, please visit the official OMTech webodwiedź witrynę lub zapoznaj się z danymi kontaktowymi podanymi przy zakupie.