Informacje dotyczące bezpieczeństwa

Your ProCom heater is designed with safety in mind. It is a ventless unit, meaning it does not require an outside duct or chimney. However, proper ventilation is still crucial for safe operation. This heater is equipped with an Oxygen Depletion Sensor (ODS) that automatically shuts down the unit if oxygen levels become too low. It is ANSI Certified to ensure safety standards are met.

Cechy produktu

ProCom MN180TPA-B Features Diagram

Image: Diagram highlighting key features of the ProCom heater, including BTU output, ventless operation, natural gas compatibility, no electricity requirement, safety features, Piezo ignition, and thermostat mode.

Organizować coś

The ProCom MN180TPA-B heater offers flexible installation options: wall-mounted or floor-standing.

Rozpakowywanie i kontrola

Wybór lokalizacji

Select a location that allows for proper clearances from combustible materials. Ensure the area has adequate ventilation as per local codes and the heater's specifications.

Opcje instalacji

Podłoga stojąca: Attach the included base feet to the bottom of the heater using the provided hardware. Ensure the heater is stable and level.

Montaż na ścianie: Use the included wall mounting bracket and hardware. Follow the detailed instructions in the manufacturer's full installation guide for secure wall attachment and proper clearances.

ProCom MN180TPA-B Included Components

Image: Components included with the ProCom heater, showing the main unit, base feet, wall bracket, and highlighting the Oxygen Depletion Sensor and natural gas operation.

ProCom MN180TPA-B Wall Mounted

Image: The ProCom MN180TPA-B heater mounted on a wall in a living space, demonstrating its compact profile and integration into a room.

Podłączenie gazu

This heater operates on natural gas only. Connection to the natural gas supply must be performed by a qualified professional in accordance with all local codes and regulations. Ensure all connections are leak-tested before operation.

Instrukcja obsługi

Follow these steps to safely operate your ProCom MN180TPA-B heater.

Procedura zapłonu

  1. Upewnij się, że zawór zasilania gazem jest otwarty.
  2. Turn the control knob to the 'PILOT' position.
  3. Press and hold the control knob in while simultaneously pressing the Piezo ignition button repeatedly until the pilot flame ignites.
  4. Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up. Release the knob; the pilot should remain lit.
  5. If the pilot does not remain lit, repeat steps 2-4.
  6. Once the pilot is stable, turn the control knob to the desired heat setting (1-5). The main burner will ignite.

Sterowanie termostatem

The heater features a thermostat control with 5 variable heat settings. Rotate the control knob to select your preferred heat output. The heater will cycle on and off to maintain the set temperature.

ProCom MN180TPA-B Thermostat Controls

Obraz: Zbliżenie view of the control panel on the ProCom heater, showing the Piezo ignitor button and the rotary knob for 5 variable heat settings and pilot control.

Wyłączanie ogrzewania

  1. Turn the control knob to the 'OFF' position.
  2. For prolonged shutdown, close the main gas supply valve to the heater.

Konserwacja

Regularna konserwacja zapewnia długowieczność i bezpieczną pracę Twojego ogrzewacza.

Rozwiązywanie problemów

If you encounter issues with your heater, refer to the following common problems and solutions. For persistent issues, contact a qualified service technician.

ProblemMożliwa przyczynaRozwiązanie
Pilot się nie zapaliNo gas supply; Air in gas line; Pilot orifice clogged; Faulty thermocoupleCheck gas supply; Purge air from line; Clean pilot orifice; Contact technician
Pilot lights but will not stay litThermocouple not heating sufficiently; Loose thermocouple connection; Faulty ODS pilot assemblyHold knob longer; Tighten connection; Contact technician
Main burner will not ignitePilot not lit; Main burner orifice clogged; Low gas pressureEnsure pilot is lit; Clean burner orifice; Contact gas provider/technician
Heater cycles off frequentlyInsufficient ventilation; ODS activation; Thermostat setting too high for room sizeIncrease ventilation; Check for obstructions; Adjust thermostat setting

Specyfikacje

AtrybutSzczegół
MarkaProCom
Numer modeluMN180TPA-B
Typ paliwaGaz ziemny
Maximum BTU Output18,000 BTU
Zasięg ogrzewaniaDo 950 stóp kwadratowych.
Typ zapłonuPush Button Piezo
Typ sterowaniaThermostat (High/Medium/Low)
Funkcje bezpieczeństwaCzujnik niedoboru tlenu (ODS)
Opcje montażuWall Mount, Floor Standing (Base Feet Included)
Wymiary produktu8" gł. x 22" szer. x 26" wys.
Waga przedmiotu26.2 funta
KolorBiały
CertyfikatyCSA Certified, ANSI Certified
ProCom MN180TPA-B Dimensions Diagram

Image: Diagram illustrating the dimensions of the ProCom MN180TPA-B heater: 24 inches H, 19 inches L, and 8 inches D.

Informacje o gwarancji

For detailed warranty information regarding your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, please refer to the warranty card included with your product packaging or visit the official ProCom webWarunki gwarancji mogą się różnić.

Obsługa klienta

If you require assistance, have questions about your heater, or need to report an issue, please contact ProCom customer support. Refer to your product packaging or the official ProCom website for the most current contact information, including phone numbers, email addresses, and online support resources.

Powiązane dokumenty - MN180TPA-B

Przedview Instrukcja obsługi radia dwukierunkowego Procom NEW PRO-9900 AM/FM Citizens Band
Instrukcja obsługi radia dwukierunkowego Procom NEW PRO-9900 AM/FM Citizens Band, szczegółowo opisująca jego funkcje, działanie, cechy i specyfikacje techniczne dla optymalnego użytkowania.
Przedview Instrukcja obsługi bezprzewodowego interkomu cyfrowego PROCOM Atlas Loud Mouth
W niniejszej instrukcji obsługi znajdują się szczegółowe informacje na temat bezprzewodowego interkomu cyfrowego PROCOM Atlas Loud Mouth, w tym jego funkcji, działania, danych technicznych, wytycznych dotyczących bezpieczeństwa i zgodności z normami FCC.
Przedview ProCom Heating Vent-Free Gas Space Heater: Operation and Installation Manual
Comprehensive guide for ProCom Heating vent-free gas space heaters, covering installation, operation, safety, maintenance, and troubleshooting for models MN180TPA-B, ML150TPA-B, MN300TPA-B, and ML250TPA-B.
Przedview ProCom Heating Vent-Free Gas Space Heater: Operation & Installation Manual
This manual provides essential guidance for the safe operation and installation of ProCom Heating's vent-free gas space heaters (MN180TPA-B, ML150TPA-B, MN300TPA-B, ML250TPA-B), covering safety, installation, operation, maintenance, and troubleshooting.
Przedview Instrukcja obsługi i montażu grzejnika ściennego gazowego ProCom Vent-Free
Niniejsza instrukcja zawiera instrukcje obsługi i instalacji gazowych grzejników ściennych ProCom Vent-Free, w tym modeli MN2PHG, MN2PTG, MN3PHG, MN3PTG, ML2PHG, ML2PTG, ML3PHG i ML3PTG. Obejmuje ona środki ostrożności, cechy produktu, specyfikacje, procedury instalacji, obsługę, rozwiązywanie problemów, części, akcesoria oraz informacje gwarancyjne.
Przedview Lista części zamiennych do jednostek wewnętrznych Bosch Climate serii 5000AA
Szczegółowa lista części zamiennych i schemat jednostki wewnętrznej serii Bosch Climate 5000AA, w tym numery części i informacje o zgodności dla różnych wydajności BTU.