Generac 7153

Przenośny generator inwerterowy Generac GP3300i

Instrukcja obsługi

1. Koniec produktuview

The Generac GP3300i inverter generator is designed to provide reliable and clean power for various applications, from outdoor adventures to essential home backup. Its advanced PowerRush™ technology offers increased starting capacity for motor-driven equipment, while its compact and lightweight design ensures portability. The unit includes multiple outlets and USB ports for versatile power delivery.

Główne cechy:

Przenośny generator inwerterowy Generac GP3300i

Rycina 1.1: Przód view of the Generac GP3300i Portable Inverter Generator.

Generac GP3300i Portable Power Applications

Figure 1.2: The Generac GP3300i provides portable power for camping, food trucks, DIY projects, and power outagt.j.

2. Informacje dotyczące bezpieczeństwa

Operating a generator safely is paramount. Please read and understand all safety warnings and instructions before operating this unit. Failure to follow these instructions can result in serious injury or death.

Zagrożenie tlenkiem węgla:

Bezpieczeństwo elektryczne:

Bezpieczeństwo paliwa:

3. Przewodnik konfiguracji

Rozpakowywanie:

Carefully remove the generator and all accessories from the packaging. Inspect the unit for any damage that may have occurred during shipping. Retain packaging for future storage or transport.

Dodawanie oleju silnikowego:

The generator is shipped without engine oil. It is crucial to add the correct amount and type of oil before the first start-up. Refer to the oil capacity in the specifications section.

  1. Umieść generator na równej powierzchni.
  2. Znajdź korek wlewu oleju/bagnet.
  3. Using the provided funnel, slowly add the recommended engine oil (typically 10W-30 for general use) until it reaches the upper mark on the dipstick. Do not overfill.
  4. Dokładnie zakręć korek wlewu oleju/bagnet.

Dodawanie paliwa:

Use fresh, unleaded gasoline with an octane rating of 87 or higher. Do not use E85 or any other fuel type.

  1. Upewnij się, że generator jest wyłączony i chłodny.
  2. Zdejmij korek wlewu paliwa.
  3. Carefully pour gasoline into the fuel tank, avoiding overfilling. Leave a small air gap at the top to allow for fuel expansion. The tank volume is approximately 1.06 gallons.
  4. Dokładnie zakręć korek wlewu paliwa.

Kontrole wstępne:

4. Instrukcja obsługi

Uruchamianie generatora:

  1. Upewnij się, że generator znajduje się na równej powierzchni i wszystkie obciążenia elektryczne są odłączone.
  2. Przekręć zawór paliwa do pozycji „ON”.
  3. Move the choke lever to the 'CHOKE' position (if the engine is cold).
  4. Płynnie i mocno pociągnij za uchwyt rozrusznika, aż silnik uruchomi się.
  5. Po uruchomieniu silnika powoli przesuń dźwignię ssania do pozycji „PRACA”.

Podłączanie urządzeń:

The GP3300i features various outlets for connecting your devices:

Once the generator is running stably, you can plug in your electrical devices. Always ensure the total wattagmoc podłączonych urządzeń nie przekracza mocy roboczej generatoratage (2500 Watts) or starting wattage (3300 watów).

Generac GP3300i Control Panel and Features

Figure 4.1: The control panel highlights PowerRush technology, ultra-quiet operation, and convenient USB ports.

Tryb ekonomiczny:

Activate Economy Mode to automatically adjust engine speed to match the load. This reduces fuel consumption and noise levels when full power is not required. The generator will automatically rev up when more power is needed.

Praca równoległa:

The GP3300i is parallel-ready, allowing you to connect two compatible Generac inverter generators together using a parallel kit (sold separately) to double your power output. Refer to the parallel kit's instructions for proper connection.

Zatrzymanie generatora:

  1. Odłącz wszystkie odbiorniki elektryczne od generatora.
  2. Pozostaw generator na kilka minut włączony bez obciążenia, aby ostygł.
  3. Przekręć wyłącznik silnika do pozycji „WYŁĄCZONY”.
  4. Turn the fuel valve to the 'OFF' position for storage.

5. Konserwacja

Regular maintenance is essential for the longevity and optimal performance of your Generac GP3300i generator. Always ensure the generator is off and cool before performing any maintenance.

Regularne kontrole:

Wymiana oleju:

Perform the first oil change after the initial 20 hours of operation, and then every 50-100 hours or annually, whichever comes first. Refer to the engine oil specifications for type and capacity.

Czyszczenie/wymiana filtra powietrza:

Inspect the air filter regularly (every 25-50 hours or more frequently in dusty conditions). Clean or replace as necessary to ensure proper engine performance.

Kontrola świec zapłonowych:

Inspect the spark plug every 100 hours or annually. Clean or replace if it is fouled, worn, or damaged. Ensure the correct gap is maintained.

Składowanie:

If storing the generator for more than 30 days, it is recommended to drain the fuel system or use a fuel stabilizer to prevent fuel degradation. Store the generator in a clean, dry place.

6. Rozwiązywanie Problemów

This section provides solutions to common operational issues. For problems not listed here or if solutions do not resolve the issue, contact Generac customer support.

ProblemMożliwa przyczynaRozwiązanie
Silnik nie chce się uruchomićNo fuel; Low oil level; Choke not set correctly; Spark plug issue; Stale fuelAdd fuel; Add oil; Adjust choke; Inspect/replace spark plug; Drain and refill with fresh fuel
Brak mocy wyjściowejOverload; Circuit breaker tripped; ECO mode engaged with high load; Faulty connectionReduce load; Reset circuit breaker; Turn off ECO mode for high loads; Check connections
Silnik pracuje nierówno/gaśnieDirty air filter; Stale fuel; Clogged fuel filter; Spark plug issueClean/replace air filter; Drain and refill with fresh fuel; Replace fuel filter; Inspect/replace spark plug
Overload indicator light onGenerator jest przeciążonyDisconnect all loads, turn off generator, restart, and reconnect loads one by one, ensuring total wattage mieści się w granicach.

7. Specyfikacje techniczne

Detailed specifications for the Generac GP3300i Portable Inverter Generator.

SpecyfikacjaWartość
Nazwa modeluGP3300i
Numer modelu7153
Początkowa wattage3300 watów
Bieganie Wattage2500 watów
Typ paliwaBenzyna
Objętość zbiornika1.06 galony
Czas pracy (przy obciążeniu 50%)4.5 godzin (w przybliżeniu)
Typ silnika4-suwowy
Pojemność silnika149 centymetrów sześciennych
Tomtage120 wolty
Częstotliwość60 Hz
Waga przedmiotu26.99 Pounds (approx. 59.5 lbs)
Wymiary produktu (dł. x szer. x wys.)22.2" x 13.4" x 18.4"
Całkowita moc gniazdek2 (plus USB ports)
Funkcja specjalnaCO Sensor, Portable
UPC696471086263
Generac GP3300i Dimensions and Wattage

Figure 7.1: Key dimensions and wattage ratings for the Generac GP3300i.

Generator Wtage Requirements Chart

Figure 7.2: A guide to typical running and starting wattage requirements for various devices.

8. Gwarancja i wsparcie

Generac stands behind the quality of its products. The GP3300i Portable Inverter Generator typically comes with a limited warranty.

Informacje o gwarancji:

Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the official Generac warranty statement included with your product or visit the Generac webstrona.

Obsługa klienta:

For technical assistance, parts, or service, please contact Generac customer support. Have your model number (7153) and serial number ready when contacting support to expedite service.

You can find more information and support resources on the official Generac webstrona: www.generac.com

Powiązane dokumenty - 7153

Przedview Generator inwerterowy Generac GP3300i serii GP: funkcje, specyfikacje i panel sterowania
Poznaj generator inwerterowy Generac GP3300i serii GP, poznaj jego zaawansowane funkcje, takie jak technologia COsense® i PowerRush™, szczegółowe specyfikacje i układ panelu sterowania. Dowiedz się więcej o jego czystej mocy wyjściowej, mobilności i możliwościach pracy równoległej.
Przedview Generator przenośny Generac GP7500E DF: dwupaliwowy, technologia COsense, 7500 watów
Poznaj przenośny generator Generac GP7500E DF. Wyposażony w dwa rodzaje paliwa (benzyna/propan), czujnik COsense, rozruch elektryczny, technologię PowerRush i moc rozruchową 7500 watów. Zawiera szczegółowe specyfikacje, wymiary i funkcje zapewniające niezawodne wytwarzanie energii.
Przedview Instrukcja obsługi generatora przenośnego Generac GP2500i
Kompleksowa instrukcja obsługi przenośnego generatora Generac GP2500i, obejmująca kwestie bezpieczeństwa, obsługi, konserwacji i rozwiązywania problemów. Dowiedz się, jak bezpiecznie obsługiwać i konserwować generator, aby zapewnić jego optymalną wydajność.
Przedview Instrukcja obsługi przenośnego generatora Generac Guardian Ultra Source
Kompleksowa instrukcja obsługi przenośnych generatorów Generac Guardian Ultra Source (modele 004451 i 004582). Obejmuje ona bezpieczeństwo, obsługę, konserwację, rozwiązywanie problemów, części i gwarancję dla niezawodnego wytwarzania energii.
Przedview Instrukcja obsługi generatora inwerterowego Generac iX 2000
Kompleksowa instrukcja obsługi generatora inwerterowego Generac iX 2000, obejmująca informacje na temat bezpieczeństwa, obsługi, konserwacji, rozwiązywania problemów i gwarancji na niezawodne wytwarzanie energii.
Przedview Instrukcja obsługi przenośnego generatora Generac serii GP – Bezpieczeństwo, obsługa, konserwacja
Kompleksowa instrukcja obsługi przenośnych generatorów Generac GP Series o mocy 7,000 i 8,000 W. Zawiera informacje na temat bezpieczeństwa, montażu, obsługi, konserwacji, rozwiązywania problemów i gwarancji.