Wstęp
This manual provides instructions for the installation, operation, and maintenance of the Opengear CM8100 Console Server. The CM8100 series is designed to provide secure out-of-band management for network and server infrastructure, enabling remote access and control even during primary network outagt.j.
Key features of the CM8100 Console Server include:
- 16, 32, or 48 port serial console server with Smart Out-of-Band™ capabilities.
- Support for Data Center and Enterprise Network automation with Python and Docker.
- Embedded physical security via TPM 2.0 module.
- Dual power supplies for redundancy and independent monitoring.
- Integrated environmental temperature monitoring.
Konfiguracja i instalacja
This section guides you through the physical installation and initial setup of your CM8100 Console Server.
Rozpakowywanie urządzenia
Carefully unpack all components from the box. Verify that all items listed in the "What's in the Box" section are present and undamaged.
Obraz: Przód view of the Opengear CM8100 Console Server, showing the red and black chassis, Opengear logo, model number, and dual power inlets on the right side.
Montaż w stojaku
The CM8100 Console Server is designed for standard 19-inch rack installation.
- Attach the two rack ears to the sides of the console server using the provided M4 screws.
- Secure the console server into the rack using the four M5x15mm rack screws and M5mm caged nuts. Ensure the device is level and securely fastened.
Podłączenie zasilania
The CM8100 features dual power supplies for redundancy.
- Connect the two A/C power cables to the power inlets on the rear of the console server.
- Connect the other ends of the power cables to independent power sources for redundancy.
- Verify that the power indicator LEDs on the front panel illuminate, indicating successful power-up.
Połączenie sieciowe
Connect the console server to your network for management access.
- Connect an Ethernet cable from your network switch to the primary network port on the console server.
- (Optional) Connect a second Ethernet cable to the secondary network port for network redundancy.
Połączenie portu szeregowego
Connect your managed devices (servers, network devices) to the serial ports on the CM8100.
- Identify the serial ports on the rear of the console server.
- Use appropriate serial cables (e.g., the provided CAT5 patch cable with DB9F-RJ45 rollover serial adapter) to connect your devices to the CM8100 serial ports.
- Note the port numbers for future configuration.
Obraz: Tył view of the Opengear CM8100 Console Server, displaying various network and serial console ports, along with dual power supply connections.
Działanie
This section covers basic operation and initial access to the CM8100 Console Server.
Dostęp początkowy
Access the console server for initial configuration via a direct serial connection or network connection.
Serial Console Access
- Connect a computer to the console server's dedicated console port using a serial cable.
- Configure your terminal emulation software (e.g., PuTTY, Tera Term) with the following settings: 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control.
- Power on the CM8100. The boot process will display on your terminal.
- Log in using the default credentials (refer to the Quick Start Guide for default username and password).
Network Access (Web Berło)
Once the device has an IP address (either DHCP assigned or manually configured via serial console), you can access the web interfejs.
- Otwórz web browser and enter the IP address of the CM8100.
- Zaloguj się używając swoich danych.
- Z web interface, you can configure serial ports, network settings, user accounts, and other system parameters.
Zarządzanie podłączonymi urządzeniami
The CM8100 allows you to connect to the console of your attached devices.
- Serial Console Access: Z web interface or command-line interface (CLI), select the desired serial port to establish a connection to the attached device.
- Out-of-Band Management: Utilize the Smart OOB™ features to access and manage devices even when the primary network is down.
Konserwacja
Regular maintenance ensures optimal performance and longevity of your CM8100 Console Server.
Aktualizacje oprogramowania układowego
Periodically check the Opengear website for firmware updates. Keeping the firmware current provides new features, bug fixes, and security enhancements.
- Download the latest firmware image from the official Opengear support portal.
- Access the CM8100 web interfejs.
- Navigate to the firmware update section (typically under System > Firmware).
- Postępuj zgodnie z instrukcjami wyświetlanymi na ekranie, aby przesłać i zainstalować nowe oprogramowanie układowe. Nie wyłączaj urządzenia podczas procesu aktualizacji.
Czyszczenie
Keep the console server clean to prevent dust buildup, which can affect cooling.
- Do przecierania zewnętrznej części urządzenia należy używać miękkiej, suchej ściereczki.
- Upewnij się, że otwory wentylacyjne są drożne.
- Nie należy stosować płynnych środków czyszczących bezpośrednio na urządzeniu.
Zagadnienia środowiskowe
Ensure the operating environment meets the recommended conditions.
- Maintain proper airflow around the device.
- Keep the device within specified temperature and humidity ranges.
Rozwiązywanie problemów
This section provides solutions to common issues you might encounter with the CM8100 Console Server.
Brak zasilania
- Objaw: Power indicator LEDs are off, device does not respond.
- Rozwiązanie: Verify that both A/C power cables are securely connected to the device and to active power outlets. Check power sources and circuit breakers.
Nie można uzyskać dostępu Web Interfejs
- Objaw: Web browser cannot connect to the CM8100 IP address.
- Rozwiązanie:
- Verify the console server has power and is running.
- Confirm the network cable is properly connected to an active network port.
- Check the IP address configuration of the CM8100 (via serial console if necessary).
- Ensure your computer is on the same network or has a route to the CM8100's IP address.
- Temporarily disable any firewalls on your computer to rule out interference.
No Serial Console Connection to Managed Device
- Objaw: Unable to establish a serial connection to a device connected to the CM8100.
- Rozwiązanie:
- Verify the serial cable connection between the CM8100 port and the managed device.
- Ensure the correct serial cable type (e.g., rollover, straight-through) is used for the specific device.
- Check the serial port configuration on the CM8100 (baud rate, data bits, parity, stop bits, flow control) matches the settings of the managed device.
- Confirm the managed device is powered on and functioning correctly.
Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Marka | Otwarta skrzynia |
| Szereg | CM8100 Console Server |
| Numer modelu | CM8116 |
| Waga przedmiotu | 8.63 funta |
| Wymiary produktu (dł. x szer. x wys.) | 19.5 x 16.5 x 3.5 cala |
| Producent | Otwarta skrzynia |
| Pierwszy dostępny | 16 lutego 2023 r. |
Co jest w pudełku
The following items are included with your Opengear CM8100 Console Server:
- CM8100 Console Server
- Zestaw do montażu w szafie
- 2 x Rack Ears with Six M4 Screws
- 4 x M5mm Caged Nuts
- 4 x M5x15mm Rack Screws
- 1 x CAT5 Patch Cable 6'
- 1 x DB9F-RJ45 Rollover Serial Adapter
- 2 x A/C Power Cables
- Szybki przewodnik
- Lighthouse Insert