Prity AM W12

Prity AM W12 Wood-Burning Stove with Boiler for Central Heating

Instrukcja obsługi

1. Wprowadzenie

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Prity AM W12 wood-burning stove with an integrated boiler for central heating. Please read this manual thoroughly before using the appliance and retain it for future reference. The Prity AM W12 is designed to provide both room heating and hot water for your central heating system.

2. Instrukcje bezpieczeństwa

Twoje bezpieczeństwo i bezpieczeństwo innych jest najważniejsze. Zawsze przestrzegaj poniższych zasad bezpieczeństwa:

  • Profesjonalna instalacja: Installation must be performed by a qualified professional in accordance with all local and national building codes and regulations.
  • Materiały palne: Maintain minimum clearances from combustible materials. As per EN 13240:2001/A2:2004/AC:2007, the minimum distances are:
    • Tył: 400 mm
    • Sides (left and right): 400 mm
    • Front (radiation from pane): 800 mm
    • Sufit: 600 mm
  • Typ paliwa: Only use dry wood with a moisture content of ≤20% or charcoal. Never use flammable liquids, plastics, or treated wood as fuel.
  • Gorące powierzchnie: The stove's exterior surfaces become extremely hot during operation. Use appropriate protective gloves when handling and keep children and pets away.
  • Wentylacja: Ensure adequate ventilation in the room where the stove is installed to prevent oxygen depletion.
  • Komin/Przewód kominowy: Regularly inspect and clean the chimney and flue pipe to prevent creosote buildup and ensure proper draft.
  • Tlenek węgla: Install a carbon monoxide detector in the vicinity of the stove.
  • System wodny: The integrated boiler must be connected to a closed central heating system by a qualified plumber. Ensure the system is properly filled and vented. The maximum working pressure is 1.25 bar.

This product complies with EN standard, CE certification, BlmSchV2, and ECO design regulations.

3. Konfiguracja i instalacja

The Prity AM W12 is designed for corner placement and built-in installation. Proper setup is crucial for safety and performance.

3.1 Rozpakowanie i kontrola

Carefully unpack the stove and inspect it for any damage that may have occurred during transit. Report any damage to your supplier immediately.

3.2 Umieszczenie

Position the stove in the desired corner, ensuring it meets the minimum clearance requirements from combustible materials as detailed in the Safety Instructions section.

Prity AM W12 wood-burning stove installed in a corner with a fire burning inside.

Image 3.2.1: The Prity AM W12 stove installed in a corner setting, demonstrating typical placement.

3.3 Podłączenie rury spalinowej

Connect the stove to a suitable chimney or flue system. The flue pipe diameter required is 150 mm. Ensure all connections are sealed properly to prevent smoke leakage and ensure optimal draft.

3.4 Central Heating System Connection

The integrated water boiler requires connection to your central heating system. This must be done by a certified plumber. The boiler has a volume of 7 liters and is designed to operate at a maximum working pressure of 1.25 bar. Ensure the system is properly filled, vented, and tested for leaks before initial firing.

Strona view of the Prity AM W12 wood-burning stove, showing the flue pipe connection point at the top.

Obraz 3.4.1: Bok view of the Prity AM W12 stove, highlighting the flue outlet and overall construction.

4. Instrukcja obsługi

Follow these steps for safe and efficient operation of your Prity AM W12 stove.

4.1 Fueling the Stove

Open the main combustion chamber door using the wooden handle. Place a small amount of kindling and firelighters on the cast iron grate. Once ignited, gradually add small pieces of dry wood or charcoal. Do not overfill the combustion chamber.

Prity AM W12 wood-burning stove with a vibrant fire burning inside the combustion chamber.

Image 4.1.1: The Prity AM W12 stove in operation, showing a fire burning within the heat-resistant ceramic glass window.

Prity AM W12 wood-burning stove with the combustion chamber door closed, showing the empty interior and cast iron grate.

Image 4.1.2: The Prity AM W12 stove with the combustion chamber empty, illustrating the interior design and cast iron grate.

4.2 Air Supply Control

The stove is equipped with a front damper for regulating the air supply to the combustion chamber. Open the damper fully during ignition to establish a strong fire. Once the fire is established, adjust the damper to control the burn rate and heat output. A fully open damper provides more air, leading to a hotter, faster burn. A partially closed damper reduces air, resulting in a slower, more efficient burn.

4.3 Flame Intensity Adjustment

Dym damper is provided to adjust the flame intensity. This allows for fine-tuning of the combustion process and heat distribution.

4.4 Tankowanie

When adding more fuel, open the air damper fully for a few minutes before opening the combustion chamber door. This helps to prevent smoke from entering the room. Add fuel carefully and close the door securely.

5. Konserwacja

Regular maintenance ensures the longevity and efficient operation of your Prity AM W12 stove.

5.1 Usuwanie popiołu

Regularly remove ash from the ash pan located below the combustion chamber. Ensure the stove is completely cool before performing this task. Dispose of ash in a non-combustible container.

5.2 Cleaning the Combustion Chamber

Periodically clean the interior of the combustion chamber, including the heat-resistant ceramic glass. Use a soft brush or vacuum cleaner for ash and a specialized glass cleaner for stove glass. Do not use abrasive cleaners.

5.3 Flue Pipe and Chimney Cleaning

The flue pipe and chimney should be inspected and cleaned at least once a year, or more frequently depending on usage. This prevents creosote buildup, which can lead to chimney fires and reduced efficiency. This task should be performed by a qualified chimney sweep.

5.4 Boiler System Check

Regularly check the pressure in your central heating system and ensure it is within the recommended operating range. Inspect all connections for leaks. Consult a qualified plumber for any issues with the boiler system.

6. Rozwiązywanie Problemów

This section addresses common issues you might encounter with your Prity AM W12 stove. For complex problems, consult a qualified technician.

  • Poor Draft / Smoke in Room:
    • Check if the flue pipe or chimney is blocked and requires cleaning.
    • Ensure the air dampers are open sufficiently.
    • Verify that the chimney height and diameter are adequate for the stove.
    • Check for negative pressure in the room (e.g., due to extractor fans).
  • Niska emisja ciepła:
    • Ensure you are using dry, seasoned wood. Wet wood burns inefficiently.
    • Check if the air dampers are open enough.
    • Verify that the combustion chamber and ash pan are clean.
  • Nadmierne zużycie paliwa:
    • Wyreguluj powietrze dampers to reduce the burn rate.
    • Ensure the stove door seals are intact and not allowing excess air.
  • Water System Not Heating:
    • Check the central heating system pressure.
    • Ensure the boiler is receiving sufficient heat from the combustion.
    • Bleed the radiators and the boiler system to remove any airlocks.
    • Jeśli problem nadal występuje, skonsultuj się z wykwalifikowanym hydraulikiem.

7. Specyfikacje

Detailed technical specifications for the Prity AM W12 wood-burning stove with boiler:

Table showing product information and technical specifications for Prity AM W12 stove.

Image 7.1.1: Product Information table for Prity AM W12, detailing various technical specifications.

FunkcjaSpecyfikacja
Numer modeluAM W12
Total Dimensions (W x D x H)Wymiary: 720 x 550 x 820 mm
Combustion Chamber Dimensions (W x D x H)Wymiary: 635 x 450 x 315 mm
Masa netto113 kilogramów
Nominal Room Heating Output6.2 kW
Nominal Water Heating Output7.3 kW
Maximum Water Heating Output12 kW
Średnica rury spalinowej150 mm
Efektywność76.5%
Volume of Water Heater7 Ł
Estimated Heating Area105 m²
Estimated Heating Capacity277 m³
Materiał korpusu2 mm thick sheet steel
Materiał wierzchni3-4 mm thick sheet steel
Typ paliwaWood, Charcoal (Dry wood with moisture content ≤20%)
Maksymalne ciśnienie robocze1.25 bar
Flue Gas Temperature at Nominal Heat Output180 °C
Minimum Chimney Draft11.4 Pa
Zużycie paliwa4.3 kg/godz.
Przyłącze armatury3/4"
Klasa efektywności energetycznejA
Wskaźnik efektywności energetycznej (EEI)102
Sezonowa efektywność energetyczna ogrzewania pomieszczeń (ηs)68%
KolorCzarny grafit
Zawiera elementyCast iron grate, Wooden door handles
Energy efficiency label for Prity AMW12 stove, showing an A rating and heat output values.

Image 7.1.2: Energy Label for Prity AMW12, indicating an A-class energy efficiency rating.

German Declaration of Performance for Prity AMW12, detailing compliance with standards and technical data.

Image 7.1.3: German Declaration of Performance for Prity AMW12, showing compliance and performance data.

English Declaration of Performance for Prity AMW12, detailing compliance with standards and technical data.

Image 7.1.4: English Declaration of Performance for Prity AMW12, providing essential performance characteristics.

EAN/Barcode: 3800215095054

8. Gwarancja i wsparcie

For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. In case of technical issues or questions not covered in this manual, please contact Prity customer support or your authorized service provider.

Powiązane dokumenty - AM W12

Przedview Kotły Prity: opis techniczny, instalacja i instrukcja obsługi
Kompleksowy przewodnik po kotłach mieszkaniowych Prity, obejmujący specyfikacje techniczne, procedury instalacji, instrukcje obsługi, konserwację i rozwiązywanie problemów dla modeli na paliwo stałe i pellet.
Przedview Instrukcja obsługi ładowarki bezprzewodowej W12
Instrukcja obsługi przenośnej ładowarki bezprzewodowej W12 firmy Guangdong Gadmei Intelligent Technology Co., LTD. Dowiedz się więcej o funkcjach produktu, specyfikacji, metodach ładowania, środkach ostrożności i rozwiązywaniu problemów.
Przedview Słuchawki Bluetooth SANSUI W12 – specyfikacje i zgodność z normami FCC
Oficjalne informacje na temat zestawu słuchawkowego Bluetooth SANSUI W12, obejmujące specyfikacje techniczne i oświadczenia dotyczące zgodności z normami FCC.
Przedview Instrukcja obsługi składanej bezprzewodowej ładowarki do zegarków Joyroom JR-W12
Instrukcja obsługi składanej bezprzewodowej ładowarki do zegarków Joyroom JR-W12, zawierająca szczegółowe dane techniczne, obsługę i ostrzeżenia dotyczące bezpieczeństwa. Zawiera informacje na temat produktu, sposobu jego obsługi, opisu funkcji oraz zgodności z dyrektywami UE.
Przedview Instrukcja obsługi wielofunkcyjnej myjki podłogowej Redkey W12 Pro 4 w 1
Kompleksowa instrukcja obsługi wielofunkcyjnej myjki podłogowej Redkey W12 Pro 4 w 1, obejmująca zagadnienia bezpieczeństwa, montażu, obsługi, konserwacji i rozwiązywania problemów.