Leviton LP622-BPD

Leviton LP622-BPD 66 Space, 66 Circuit Indoor Load Center User Manual

Model: LP622-BPD

1. Wprowadzenie

This manual provides detailed instructions for the installation, operation, and maintenance of the Leviton LP622-BPD 66 Space, 66 Circuit Indoor Load Center with a 225 Amp Main Circuit Breaker. Please read this manual thoroughly before proceeding with any installation or operation to ensure safe and correct usage of the product.

2. Informacje dotyczące bezpieczeństwa

WARNING: Risk of electric shock or electrocution. Installation and servicing of this equipment must be performed by qualified personnel only. Always disconnect power at the main service panel before working on or near the load center.

3. Koniec produktuview

The Leviton LP622-BPD is a 66-space, 66-circuit indoor load center designed for residential and light commercial applications. It features a factory-installed 225 Amp main circuit breaker and tin-plated copper bussing for superior conductivity. The modern design includes a white, powder-coated finish. The enclosure and interior are included; the door is sold separately.

Główne cechy:

Leviton LP622-BPD Load Center Interior

Rysunek 3.1: Wnętrze view of the Leviton LP622-BPD Load Center, showing the main breaker and circuit breaker spaces.

4. Instalacja i konfiguracja

Installation of the Leviton LP622-BPD Load Center should only be performed by a qualified electrician. Follow these general steps:

  1. Montaż obudowy: Securely mount the load center enclosure to a suitable surface, ensuring it is level and plumb.
  2. Rough-in Wiring: Route all incoming and outgoing electrical wires into the load center. The design allows for wiring without breakers installed, simplifying the process.
  3. Connecting Main Power: Connect the main service entrance conductors to the factory-installed 225 Amp main circuit breaker.
  4. Connecting Branch Circuits: Connect the individual branch circuit wires to the appropriate terminals within the load center. Utilize the cable tie notches for organized wiring.
  5. Installing Circuit Breakers: Once wiring is complete, snap the individual circuit breakers into their designated spaces. The plug-on design ensures easy and secure installation.
Installing a Leviton Plug-on Circuit Breaker

Figure 4.1: A hand demonstrating the installation of a plug-on circuit breaker into the load center bussing.

Leviton Load Center with organized wiring

Rysunek 4.2: Byłyample of a Leviton Load Center with neatly organized wiring, utilizing the integrated cable tie notches.

Optional Smart Home Integration:

The Leviton Load Center is compatible with Leviton's smart circuit breakers and whole-house energy monitor for advanced energy management and monitoring. This involves:

  1. Install the Leviton Whole House Energy Monitor.
  2. Snap in 2nd Gen Smart Circuit Breakers.
  3. Enroll Breakers in the My Leviton App.
Leviton Smart Home Integration Steps

Figure 4.3: Visual representation of the three steps for integrating the load center with Leviton's smart home ecosystem.

5. Działanie

Operating the Leviton Load Center primarily involves managing the circuit breakers. Each circuit breaker controls a specific electrical circuit in your property.

Leviton Load Center with observation window

Rysunek 5.1: Zbliżenie view of circuit breakers within the load center, visible through an observation window in the cover.

Leviton Load Center Door Options

Figure 5.2: Comparison of a standard door and a window door option for the Leviton Load Center. Note: Door sold separately.

6. Konserwacja

Regular maintenance helps ensure the longevity and safe operation of your Leviton Load Center. Always disconnect power before performing any maintenance.

7. Rozwiązywanie Problemów

W tej sekcji omówiono typowe problemy, jakie mogą wystąpić w centrum załadunku.

ProblemMożliwa przyczynaRozwiązanie
Częste wyłączanie wyłącznika obwoduPrzeciążenie obwodu, zwarcie lub zwarcie doziemne.Reduce load on the circuit. Inspect wiring and appliances for faults. If problem persists, consult an electrician.
No power to a specific circuitTripped breaker, loose connection, or faulty breaker.Check and reset the breaker. Inspect connections (with power off). If necessary, replace the breaker.
Main breaker tripsSystem-wide overload or major fault.Turn off all branch circuit breakers, then reset the main breaker. Turn on branch breakers one by one to identify the faulty circuit. If problem persists, contact a qualified electrician immediately.

For issues not covered here, or if you are unsure about any troubleshooting step, contact a qualified electrician or Leviton customer support.

8. Specyfikacje

AtrybutSzczegół
Numer modeluLP622-BPD
MarkaLewiton
Wymiary produktu55.8 x 14.3 x 4 cala
Waga51 funtów
Prąd zasilacza sieciowego225 Amps
TworzywoMiedź
Liczba obwodów66
Rodzaj fazyTrójfazowy
Ocena NEMANEMA 1 (Indoor Use)

9. Gwarancja i wsparcie

Leviton products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official Leviton website. If you require technical assistance, have questions about installation, or need to report a product issue, please contact Leviton customer support.

Leviton Customer Support:

Powiązane dokumenty - LP622-BPD

Przedview Instrukcja montażu obudowy centrum załadunku Leviton
Szczegółowa instrukcja montażu obudów rozdzielnic Leviton Load Center, modele LP2xx, LP3xx, LP4xx i LP6xx. Obejmuje ona kwestie bezpieczeństwa, wyłamywanie wyłamywanych otworów, montaż, okablowanie, instalację wyłącznika obwodu odgałęzionego oraz montaż pokrywy.
Przedview Leviton Load Center Phase Maps Installation Guide
This guide provides phase map illustrations to simplify the installation of the Leviton Whole Home Energy Monitor (LWHEM). It details where to terminate power wires and mount the Smart Mains Metering Accessory CTs for monitoring whole-home energy consumption.
Przedview Mój przewodnik po aplikacji Leviton: Kontroluj inteligentne urządzenia domowe
Zapoznaj się z przewodnikiem po aplikacji My Leviton, aby łatwo zarejestrować, zintegrować i dostosować urządzenia Decora Smart Wi-Fi oraz Leviton Load Center za pomocą inteligentnych wyłączników, co pozwoli na bezproblemową kontrolę inteligentnego domu.
Przedview Mój przewodnik po aplikacji Leviton: Inteligentne sterowanie domem za pomocą inteligentnego Wi-Fi i centrów ładowania Decora
Kompleksowy przewodnik po korzystaniu z aplikacji My Leviton do zarządzania urządzeniami Leviton Decora Smart Wi-Fi i centrami ładowania Leviton z inteligentnymi wyłącznikami. Obejmuje konfigurację, harmonogramy, aktywności, ustawienia urządzeń, personalizację pulpitu, monitorowanie zużycia energii i obsługę klienta.
Przedview Mój przewodnik po aplikacji Leviton: Decora Smart Wi-Fi i centrum ładowania
Kompleksowy przewodnik po korzystaniu z aplikacji My Leviton do zarządzania urządzeniami Leviton Decora Smart Wi-Fi i centrami ładowania Leviton z inteligentnymi wyłącznikami. Dowiedz się więcej o konfiguracji, zarządzaniu urządzeniami, harmonogramowaniu, monitorowaniu zużycia energii i obsłudze klienta.
Przedview Instrukcja instalacji i testowania gniazdka Leviton GFCI
Kompleksowy przewodnik na temat instalacji i testowania gniazdka GFCI Leviton SmartLock Pro, obejmujący instrukcje dotyczące okablowania, środki ostrożności i wskazówki dotyczące rozwiązywania problemów.