1. Koniec produktuview
The Hanna Instruments Marine Ammonia Checker HI784 is a compact, digital colorimeter designed for precise and rapid measurement of ammonia levels in marine (saltwater) samples. This device simplifies water quality testing by providing a clear digital readout, eliminating the need for visual color matching found in traditional chemical test kits.

Figure 1: The Hanna Marine Ammonia Checker HI784. This compact yellow device features a digital screen displaying "1.05" and "Ammonia" below it, indicating a measurement of 1.05 ppm ammonia. A single black button is located at the bottom for operation.
2. Główne cechy
- Zwiększona dokładność: Provides more accurate results compared to traditional chemical test kits.
- Obsługa przyjazna użytkownikowi: Features single-button operation for ease of use.
- Wyczyść wyświetlacz: Equipped with a large LCD screen for easy readability of measurements.
- Efektywność energetyczna: Includes an auto shut-off function to conserve battery life.
- Dedicated Parameter: Specifically designed for measuring ammonia (NH3) in marine environments.
- Zintegrowany timer: Built-in timer ensures precise reaction times for accurate results.
- Zakres pomiarowy: Capable of measuring ammonia from 0.00 to 2.50 ppm (mg/L) NH3.
3. Konfiguracja początkowa
Before using your HI784 Marine Ammonia Checker, ensure it is properly set up.
3.1 Instalacja baterii
The device requires 1 AAA battery, which is included. To install or replace the battery:
- Znajdź pokrywę komory baterii z tyłu urządzenia.
- Zdejmij pokrywę.
- Insert one AAA battery, observing the correct polarity (+/-).
- Dokładnie załóż pokrywę komory baterii.
3.2 Przygotowanie do pomiaru
Ensure you have all necessary reagents and clean cuvettes ready before beginning the measurement process.
4. Instrukcja obsługi
Follow these steps carefully to ensure accurate ammonia measurements.
4.1 Procedura pomiarowa
- Sample Przygotowanie: Upewnij się, że wodaample does not contain any debris. Prepare the sample cuvette immediately after collecting the sample ze zbiornika.
- Reagent Addition: Hold dropper bottles completely vertically and squeeze slowly to ensure correct drop size when adding reagents.
- Cuvette Handling: Whenever the cuvette is placed into the checker, it must be dry on the outside and free of fingerprints, oil, and dirt. Wipe the cuvette thoroughly with a microfiber cleaning cloth prior to insertion.
- Avoid Bubbles: Shaking the cuvette can generate bubbles, which may cause higher readings. To obtain accurate measurements, remove such bubbles by swirling or gently tapping the cuvette.
- Chronometraż: Nie pozwól zareagować sample stand too long after reagent has been added, as accuracy will be affected. The built-in timer will guide you through reaction times.
- Czytanie: Follow the specific instructions provided with your reagent kit for the exact steps to take a reading.
- Sprzedaż: Odrzuć sample immediately after the reading has been taken to prevent permanent staining of the glass cuvette.
Always refer to the specific instructions on the reagent packaging or in the full user manual for additional directions and precautions.
5. Konserwacja
5.1 Czyszczenie
- Regularly clean the outside of the checker with a soft, damp płótno.
- Ensure the cuvette is always clean and free of scratches, dirt, or fingerprints, as these can interfere with light path and affect readings. Use a microfiber cloth for cleaning cuvettes.
- Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
5.2 Przechowywanie
Store the HI784 checker in a cool, dry place away from direct sunlight and extreme temperatures. Keep reagents properly sealed and stored according to their specific instructions.
6. Rozwiązywanie Problemów
If you encounter issues with your HI784 checker, consider the following common solutions:
- Niedokładne odczyty:
- Ensure cuvettes are clean, dry, and free of scratches or fingerprints.
- Verify correct reagent addition and reaction times.
- Check for air bubbles in the sample after reagent addition; gently tap to remove.
- Upewnij się, żeample does not contain debris.
- Problemy z wyświetlaniem:
- Sprawdź poziom baterii i wymień ją w razie potrzeby.
- Ensure the battery is installed with correct polarity.
- Urządzenie nie odpowiada:
- Wymień baterię.
- Upewnij się, że komora baterii jest bezpiecznie zamknięta.
If problems persist, contact Hanna Instruments customer support for further assistance.
7. Specyfikacje techniczne
| Parametr | Specyfikacja |
|---|---|
| Model | HI784 |
| Zakres pomiaru | 0.00 do 2.50 ppm (mg/l) NH3 |
| Waga przedmiotu | 1.08 funty (około 0.49 kg) |
| Producent | Instrumenty Hanny |
| ASIN | B0B4463YTX |
| Baterie | 1 bateria AAA (w zestawie) |
| Pozycja Wymiary opakowania | 9.25 x 6.5 x 2.68 cala |
| Kolor | Żółty |
| Rozmiar (urządzenie) | Wymiary: 86.0 x 61.0 x 37.5 mm |
| Liquid Volume (Reagent) | 0.7 Milliliters (per test, typically) |
| Formularz przedmiotu | Liquid (Reagent) |
8. Gwarancja i wsparcie
For warranty information, technical support, or service inquiries, please contact Hanna Instruments directly. Refer to the official Hanna Instruments website or the product packaging for specific warranty terms and contact details.
Instrumenty Hanny Webstrona: www.hannainst.com