EBYTE ECAN-401

EBYTE ECAN-401 CAN to RS485/RS232/RS422 Serial Protocol Converter User Manual

Model: ECAN-401 | Brand: EBYTE

1. Wprowadzenie

The EBYTE ECAN-401 is an intelligent protocol conversion product designed for bidirectional data exchange between CAN-BUS and RS485/RS232/RS422 serial interfaces. This device supports a wide voltage power supply range of 8V to 28V and integrates multiple communication interfaces, making it suitable for various industrial control and data analysis applications.

This manual provides detailed instructions for the installation, configuration, and operation of the ECAN-401 converter to ensure optimal performance and reliable data transmission.

EBYTE ECAN-401 CAN to Serial Protocol Converter front view

Figure 1: EBYTE ECAN-401 CAN to Serial Protocol Converter

2. Główne cechy

  • Bidirectional conversion between CAN and RS485/RS232/RS422 protocols.
  • Supports multiple data conversion modes: transparent conversion, transparent conversion with logo, protocol conversion, Modbus RTU conversion, and custom protocol conversion.
  • Configurable RS485/RS232/RS422 interface parameters.
  • Parameter configuration via AT commands and host computer software.
  • Equipped with power, status, and data indicators for easy monitoring.
  • Multi-master and multi-slave functionality.
  • CAN interface features high protection isolation design for enhanced reliability in harsh environments.
Electrical isolation of communication ports in ECAN-401

Figure 2: Electrical isolation of communication ports for robust operation

3. Urządzenie ponadview

3.1 Komponenty i interfejsy

The ECAN-401 converter features clearly labeled interfaces for power, CAN-BUS, RS485, RS232, and RS422 connections. Refer to the device's front panel for specific pin assignments and port locations.

3.2 Wskaźniki LED

The device includes several LED indicators to provide real-time status information:

  • PWR (czerwony): Power indicator. Illuminates when the device is powered on.
  • ERR (Red): CAN bus error indicator. Illuminates when a CAN bus error is detected.
  • DATA (Green): CAN bus data indicator. Flashes when data is being transmitted or received on the CAN bus.
  • RX (Green): Serial port receiving indicator. Flashes when data is being received on the serial port (RS485/RS232/RS422).
  • TX (Green): Serial port sending indicator. Flashes when data is being transmitted on the serial port (RS485/RS232/RS422).
ECAN-401 LED indicators and their functions

Figure 3: LED Indicators and their meanings

4. Instalacja

4.1 Fizyczna instalacja

The ECAN-401 is designed for convenient DIN rail installation. Simply click the device onto a standard DIN rail. Ensure the installation location is stable, well-ventilated, and within the specified operating temperature range.

ECAN-401 DIN rail installation method

Figure 4: Simple DIN rail installation

4.2 połączeń przewodów

Connect the power supply, CAN-BUS, and serial interfaces (RS485/RS232/RS422) according to the pinout diagrams provided in the product's detailed technical documentation. Ensure all connections are secure and correctly polarized to prevent damage to the device or connected equipment.

  • Zasilanie: Connect 8V-28V DC to the V+ and V- terminals.
  • Magistrala CAN: Connect CAN_H and CAN_L to your CAN network.
  • RS485: Connect T+(A) and T-(B) to your RS485 network.
  • RS232: Connect via the DB9 female connector.
  • RS422: Connect R+, R-, T+, T- terminals.

5. Tryby pracy

The ECAN-401 supports five distinct data conversion modes, allowing flexibility for various application requirements:

Diagram illustrating the five working modes of the ECAN-401

Figure 5: Five working modes of the ECAN-401

  • Transmisja transparentna: Data is transmitted directly between CAN and serial interfaces without protocol interpretation.
  • Transparent Transmission with Logo: Similar to transparent transmission, but with added identifiers or logos for data framing.
  • Protocol Conversion: Converts data between specific CAN and serial protocols.
  • Modbus RTU Conversion: Enables communication between CAN devices and Modbus RTU serial devices.
  • Custom Protocol Conversion: Allows users to define and implement their own conversion rules for specific applications.

The desired operating mode can be configured using AT commands or the dedicated host computer software.

6. Konfiguracja

The ECAN-401 converter's parameters and operating modes can be configured through two primary methods:

  • Konfiguracja polecenia AT: Connect the device to a computer via a serial port and use a terminal program to send AT commands. This method allows for detailed control over various settings, including baud rates, data formats, and conversion rules.
  • Oprogramowanie komputera hosta: EBYTE provides dedicated software for Windows that offers a graphical user interface (GUI) for easier configuration. This software simplifies parameter setup and mode selection.

Both methods also support restoring the device to factory default settings.

7. Specyfikacje

The following table outlines the key technical specifications of the EBYTE ECAN-401 converter:

Table of technical parameters for ECAN-401

Figure 6: ECAN-401 Parameters Table

ParametrWartość
Objętość dostawtage8V ~ 28V
Szybkość transmisji CAN6kbps - 1Mbps
Szybkość transmisji portu szeregowego600 ~ 921600bps (RS232 supports 230400 only)
Data Receiving CapabilityRamki 1000 / s
Data Sending CapabilityRamki 1000 / s
RS232 Interface StandardDB9 Kobieta
RS485 Interface Standard5.08 terminali
RS422 Interface Standard5.08 terminali
ProducentEBYTE
ASINB09P11KFGD

7.1 Wymiary

Dimensional drawing of the ECAN-401 converter

Figure 7: ECAN-401 Dimensional Drawing (Dimensions in mm)

8. Rozwiązywanie Problemów

If you encounter issues with your ECAN-401 converter, consider the following:

  • Brak zasilania: Check the power supply connection and ensure it is within the 8V-28V range. Verify the PWR LED is illuminated.
  • Brak transmisji/odbioru danych: Verify all CAN and serial connections are correct. Check the DATA, RX, and TX LEDs for activity. Ensure baud rates and other communication parameters are correctly configured for both CAN and serial interfaces.
  • Problemy z poleceniem AT: If the device does not respond to AT commands, ensure the serial connection settings (baud rate, data bits, parity, stop bits) in your terminal program match the device's default or previously configured settings. Incorrect baud rate settings are a common cause for AT command communication failure.
  • CAN Bus Errors: If the ERR LED is illuminated, check the CAN bus wiring for shorts, open circuits, or incorrect termination. Ensure the CAN baud rate matches the network.
  • Incorrect Conversion: Double-check the selected operating mode and any custom protocol configurations.

If problems persist, refer to the detailed technical documentation or contact EBYTE technical support.

9. Konserwacja

The ECAN-401 converter is designed for reliable operation with minimal maintenance. To ensure longevity and optimal performance:

  • Utrzymuj urządzenie w czystości i wolne od kurzu i zanieczyszczeń.
  • Aby zapobiec przegrzaniu, należy zapewnić odpowiednią wentylację.
  • Unikaj wystawiania urządzenia na działanie ekstremalnych temperatur, wilgoci lub środowiska powodującego korozję.
  • Regularly check all cable connections for security and integrity.

No user-serviceable parts are inside the enclosure. Do not attempt to open or repair the device yourself, as this may void the warranty.

10. Wsparcie

For technical assistance, detailed documentation, or further inquiries regarding the EBYTE ECAN-401, please visit the official EBYTE website or contact their customer support channels. Ensure you have your product model and any relevant error messages or observations ready when seeking support.

Powiązane dokumenty - ECAN-401

Przedview EBYTE MA01/MA02-AXCX4040 无线调制解调器用户手册
EBYTE MA01/MA02-AXCX4040用户手册提供了关于这款4路数字输入(DI)和4路数字输出( DO)的串口I/O联网模块的详细信息。该模块支持Modbus RTU协议,适用于工业自动化、远程数据采集和控制应用。
Przedview Instrukcja obsługi serwera NB124 z dwoma portami szeregowymi
Niniejsza instrukcja obsługi zawiera kompleksową instrukcję obsługi serwera NB124 Dual Serial Port Server, dwukierunkowego serwera portów szeregowych, który integruje protokół TCP/IP w celu zapewnienia transparentnej transmisji danych między portami szeregowymi a siecią Ethernet. Obejmuje ona wprowadzenie do produktu, skróconą instrukcję obsługi, parametry techniczne, funkcje podstawowe i zaawansowane, tryby pracy oraz aktualizacje oprogramowania sprzętowego.
Przedview Instrukcja obsługi modemu bezprzewodowego EBYTE ME31-AXAX4040 | Moduł sieciowy wejścia/wyjścia
Kompleksowa instrukcja obsługi modułu sieciowego I/O EBYTE ME31-AXAX4040, szczegółowo opisująca jego funkcje, specyfikacje, połączenia, konfigurację i obsługę protokołów Modbus TCP/RTU.
Przedview EBYTE 多串口服务器 AT 指令集
本手册详细介绍了 EBYTE 多串口服务器的 AT 指令集,涵盖基本功能,Modbus功能和物联网功能,帮助用户配置和管理设备。
Przedview Instrukcja obsługi modemu bezprzewodowego ECAN-U01M/ECAN-U01MS
User manual for the ECAN-U01M/ECAN-U01MS Wireless Modem, detailing its features, installation, operation, and technical specifications. Learn how to connect, configure, and utilize this high-performance CAN-bus communication analyzer for data processing and acquisition.
Przedview Instrukcja obsługi E90-DTU(400SL47) – bezprzewodowy nadajnik-odbiornik danych EBYTE LoRa
Instrukcja obsługi modułu E90-DTU (400SL47) firmy EBYTE, wysokiej jakości radia bezprzewodowego z rozproszonym widmem LoRa klasy przemysłowej, z cyfrową transmisją bezprzewodową. Oferuje komunikację na duże odległości, interfejsy RS232/RS485 oraz solidne zabezpieczenia przeciwzakłóceniowe do zastosowań w Internecie rzeczy i przemyśle.