Instrukcja obsługi pompy obiegowej Buderus Para 7M RS 3H

Model: 8738901566

Wstęp

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Buderus Para 7M RS 3H Circulator Pump, model 8738901566. Please read these instructions carefully before installation and keep them for future reference.

Informacje dotyczące bezpieczeństwa

Produkt ponadview

The Buderus Para 7M RS 3H is a high-efficiency circulator pump designed for heating systems. It ensures optimal circulation of heating water, contributing to the efficient operation of your system.

Buderus Para 7M RS 3H Circulator Pump

Rysunek 1: Buderus Para 7M RS 3H Circulator Pump. This image shows the pump from a front-side angle, highlighting its compact design, control panel with a green button and indicator lights, and threaded connections. The label indicates it is made by Wilo Intac in France, with model details 'Para 15/7-50/SC' and technical specifications like EEI ≤ 0.20-Part 3, IPX4D, 6-50W, Imax 0.44A, PN10, TF95, 1-230V, 50/60Hz. Two sealing rings are visible in the foreground.

Dane techniczne

FunkcjaSpecyfikacja
ProducentBuderus (Made by Wilo Intac)
Numer modelu8738901566 (Replaces 7099418 / 4511423)
Wskaźnik efektywności energetycznej (EEI)≤ 0.20-Part 3
Klasa ochronyIPX4D
Pobór mocy6-50W
Maksymalny prąd0.44 A
Ciśnienie nominalnePN10
Klasa temperaturyTF95
Tomtage1-230 V, 50/60 Hz
ZgodnośćBuderus Logamax Plus GB132 T (floor-standing unit)

Konfiguracja i instalacja

  1. Przygotowanie: Ensure the heating system is depressurized and cooled down. Isolate the section where the pump will be installed using shut-off valves.
  2. Montowanie: Install the pump in the designated position, ensuring the flow direction arrow on the pump body matches the system's flow. Use the provided sealing rings for a watertight connection.
  3. Podłączenie elektryczne: Connect the pump to the electrical supply according to local regulations and the wiring diagram provided with the pump (not included in this general manual). Ensure proper grounding.
  4. Napełnianie i odpowietrzanie: After installation, refill the heating system and thoroughly vent all air from the system and the pump. This is crucial for proper operation and to prevent damage.
  5. Pierwsze uruchomienie: Gradually open the shut-off valves and restore power to the pump. Observe for leaks and unusual noises.

Instrukcja obsługi

The Buderus Para 7M RS 3H pump features a user-friendly control interface. Refer to Figure 1 for visual reference of the control panel.

Konserwacja

Regular maintenance ensures the longevity and efficient operation of your circulator pump.

Rozwiązywanie problemów

ProblemMożliwa przyczynaRozwiązanie
Pompa nie uruchamia sięNo power supply; Motor blocked; Incorrect wiringCheck power connection and circuit breaker; Consult a qualified technician to unblock motor or check wiring.
Pump runs but no circulationAir in system; Valves closed; Impeller blockedVent the system thoroughly; Open all relevant valves; Consult a qualified technician to inspect impeller.
Nietypowy hałas/wibracjeAir in system; Cavitation; Loose mounting; Bearing wearVent the system; Check system pressure; Secure mounting; Consult a qualified technician for bearing inspection.
PrzeciekLuźne połączenia; Uszkodzone uszczelkiTighten connections; Replace damaged seals (requires professional service).

Gwarancja i wsparcie

For warranty information, please refer to the documentation provided at the time of purchase or contact your Buderus dealer. Technical support can be obtained through authorized Buderus service partners.