1. Wprowadzenie
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Vertiv Geist Switched Rack Power Distribution Unit (PDU) model VP53100. Please read this manual thoroughly before using the product and retain it for future reference.
The Vertiv Geist Switched Rack PDU VP53100 is a 1U horizontal PDU designed for rack environments, featuring 30A, 208V/240V input, and (12) combination C13/C19 outlets. It includes unit-level monitoring and switched outlet capabilities for advanced power management.
2. Informacje dotyczące bezpieczeństwa
Aby zapobiec obrażeniom ciała i uszkodzeniom sprzętu, należy przestrzegać następujących środków ostrożności:
- Ensure the PDU is installed by qualified personnel in accordance with all local and national electrical codes.
- Do not operate the PDU in wet or excessively humid environments.
- Do not attempt to open or modify the PDU. There are no user-serviceable parts inside.
- Connect the PDU only to a properly grounded power source.
- Ensure the total current draw of connected equipment does not exceed the PDU's maximum rated current (30A).
- Przed przystąpieniem do prac konserwacyjnych lub instalacyjnych należy zawsze odłączyć zasilanie.
3. Koniec produktuview
The Vertiv Geist Switched Rack PDU VP53100 provides reliable power distribution and advanced monitoring features for your data center equipment. Key components include:
- Wejściowy przewód zasilający: 10ft / 3m power cord with NEMA L6-30P plug.
- Gniazda wyjściowe: (12) Combination C13/C19 outlets.
- Wyłączniki: Two circuit breakers (Circuit 1 and Circuit 2) for overcurrent protection.
- Interfejs sieciowy: Do zdalnego monitorowania i sterowania.
- Wyświetlacz lokalny: Digital display for local power metrics.

Rycina 3.1: Przód view of the Vertiv Geist Switched Rack PDU VP53100, showing the circuit breakers, network ports, and local display.

Rysunek 3.2: Tył view of the Vertiv Geist Switched Rack PDU VP53100, illustrating the (12) combination C13/C19 outlets.
4. Konfiguracja
- Montowanie: Install the PDU horizontally in a standard 19-inch rack using the provided mounting hardware. Ensure adequate airflow around the unit.
- Podłączenie zasilania: Connect the PDU's NEMA L6-30P input plug to a dedicated 30A, 208V/240V power source. Verify the power source is properly grounded.
- Podłączenie sprzętu: Connect your IT equipment power cords to the PDU's C13/C19 outlets. Distribute the load evenly across the two circuits (Circuit 1 and Circuit 2) to prevent overloading.
- Połączenie sieciowe (opcjonalnie): For remote monitoring and control, connect an Ethernet cable from the PDU's network port to your network switch. Refer to the network configuration guide for IP address setup.
- Włączanie: Once all connections are secure, switch on the circuit breakers on the front of the PDU. The local display should illuminate, indicating power is supplied.
5. Instrukcja obsługi
The Vertiv Geist Switched Rack PDU allows for local and remote management of power to connected devices.
5.1 Obsługa lokalna
- Wyświetlacz lokalny: The front panel display shows real-time power metrics such as current (Amps), tomtage (Volts), and power (kW) for the entire unit.
- Wyłączniki: Use the circuit breakers to manually switch power on or off for the respective circuits. In case of an overload, a breaker will trip, disconnecting power to its circuit. Reset by switching it back to the 'ON' position after reducing the load.
5.2 Remote Operation (Networked Units)
For units connected to a network, access the PDU's web interface or management software for advanced features:
- Outlet Switching: Individually switch outlets on or off remotely.
- Monitorowanie mocy: View detailed power consumption data per outlet or per circuit.
- Alerty i powiadomienia: Configure thresholds for current, voltage, and power to receive alerts via email or SNMP when limits are exceeded.
- Harmonogram: Schedule power cycling for connected equipment.
6. Konserwacja
The Vertiv Geist Switched Rack PDU requires minimal maintenance. Follow these guidelines:
- Regularna kontrola: Periodically inspect the PDU, power cords, and connected equipment for any signs of damage, wear, or loose connections.
- Czyszczenie: Keep the PDU clean and free of dust. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
- Aktualizacje oprogramowania układowego: Sprawdź producenta webwitryna z dostępnymi aktualizacjami oprogramowania sprzętowego, która zapewnia optymalną wydajność i bezpieczeństwo.
7. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| No power to PDU | Input power cord disconnected; upstream power failure; PDU circuit breaker tripped. | Check power cord connection; verify upstream power source; reset PDU circuit breaker. |
| Brak zasilania podłączonego urządzenia | Device power cord disconnected; PDU outlet switched off; PDU circuit breaker tripped. | Check device power cord; verify outlet status (local/remote); reset PDU circuit breaker. |
| Network access failure | Ethernet cable disconnected; incorrect IP configuration; network issue. | Verify Ethernet cable connection; check IP settings; consult network administrator. |
| Overload indication/Circuit breaker trips repeatedly | Total load exceeds circuit capacity. | Reduce the number of connected devices or redistribute load across circuits. |
8. Specyfikacje
| Funkcja | Szczegół |
|---|---|
| Numer modelu | VP53100 |
| Typ PDU | Switched, Unit Level Monitoring EC |
| Wejście Voltage | 208V / 240V |
| Prąd wejściowy | 30A |
| Wtyczka wejściowa | NEMA L6-30P |
| Gniazda wyjściowe | (12) Combination C13/C19 |
| Faza | Jednofazowy |
| Współczynnik kształtu | 1U Horizontal Rackmount |
| Pojemność mocy | 4.9kW |
| Długość przewodu zasilającego | 10ft / 3m |
| Wymiary (pakiet) | 23 x 19 x 5 cala |
| Waga przedmiotu | 14 funta |
| Producent | VERTIVE |
9. Wsparcie i gwarancja
For technical assistance, product support, or warranty information, please contact Vertiv customer service. Refer to the official Vertiv webna naszej stronie znajdziesz najnowsze dane kontaktowe i warunki gwarancji obowiązujące w Twoim regionie.
Zasoby internetowe: www.verti.com