The DB Electrical Smart Isolator Switch 48530-BX is designed to efficiently manage power distribution in vehicles with multiple battery banks. This device allows the alternator to charge all connected batteries while preventing the battery with a higher charge from draining into a lower charged battery. It ensures optimal power management and extends battery life by isolating battery banks when necessary.

This smart isolator is a direct replacement for Cole Hersee 48530BX and Navistar ZN48530 models, ensuring compatibility and reliable performance.

DB Electrical Smart Isolator Switch 48530-BX

Image showing the DB Electrical Smart Isolator Switch 48530-BX with its main body, terminals, and connecting wires. The blue label on the device indicates 'Cole Hersee Co. 48530 SERIES SMART ISOLATOR' and shows a basic wiring diagram.

2. Specyfikacje

FunkcjaSzczegół
Wejście Voltage12 V prądu stałego
Niski poziom głośnościtage9 V
Wysokie wejście Voltage16 V
Separation Voltage12.7 V
Objętość połączeniatage13.2 V
Ampwymazać200 Amps
Liczba wejść1
Number of Battery Banks2
Tryb działaniaAutomatyczny
Typ kontaktuNormalnie otwarty
Typ złączaZaciski śrubowe
Typ obwodu2-drożny
Materiał kontaktowyMiedź
Międzynarodowa Ocena OchronyIP66
ZgodnośćSAE J1455 & J1113
Wymiary produktu (dł. x szer. x wys.)5.6 x 4.3 x 3.6 cala
Waga1.2 funtów

Note: Works with all types of alternators. No efficiency loss due to diodes. Allows bi-directional charging from alternator or from shore power. Reduces load on charging system.

3. Konfiguracja i instalacja

Proper installation is crucial for the optimal performance and longevity of your Smart Isolator Switch. It is highly recommended that installation be performed by a qualified professional.

3.1 Lista kontrolna przed instalacją

  • Verify that the part fits your specific vehicle and application before beginning installation.
  • Ensure all power sources are disconnected from the vehicle's electrical system to prevent accidental short circuits or injury.
  • Gather all necessary tools, including wrenches, wire strippers, crimpers, and appropriate gauge wiring.

3.2 instrukcje okablowania

The Smart Isolator is designed to connect your primary (main) battery, auxiliary battery, and the vehicle's charging system (alternator). Refer to the wiring diagram on the product label and consult your vehicle's specific wiring schematics for detailed connections.

  1. Montowanie: Securely mount the isolator in a dry, protected location away from excessive heat or vibration. Ensure adequate ventilation.
  2. Main Battery Connection: Connect the main battery terminal of the isolator to your primary starting battery.
  3. Podłączenie dodatkowego akumulatora: Connect the auxiliary battery terminal of the isolator to your secondary (auxiliary) battery bank.
  4. Alternator/Charging System Connection: Connect the appropriate terminal on the isolator to the vehicle's alternator or charging system output.
  5. Połączenie uziemienia: Ensure a solid ground connection for the isolator to the vehicle chassis.
  6. Przewody sterujące: Connect any necessary control wires (e.g., ignition, boost, status) as per the specific wiring diagram for your application.

Use appropriate gauge wiring for all connections to handle the 200 Amps rating and ensure secure, corrosion-free terminals.

4. Działanie

The DB Electrical Smart Isolator operates automatically to manage power flow between your battery banks. Its intelligent design ensures that your auxiliary battery is charged when the engine is running, without drawing power from your main starting battery when the engine is off.

  • Ładowanie: When the vehicle's charging system (alternator) is active and the voltage reaches the connection threshold (13.2V), the isolator connects the battery banks, allowing both to charge simultaneously.
  • Izolacja: When the engine is off or the voltage drops below the separation threshold (12.7V), the isolator separates the battery banks. This prevents accessories connected to the auxiliary battery from draining the main starting battery, ensuring you always have enough power to start your vehicle.
  • Bi-Directional Charging: The isolator supports bi-directional charging, meaning it can also facilitate charging of both battery banks from an external shore power charger, if connected to the appropriate terminals.

The automatic operation requires no manual intervention, providing a seamless and reliable power management solution.

5. Konserwacja

To ensure the long-term reliability and performance of your Smart Isolator Switch, periodic maintenance is recommended:

  • Sprawdź połączenia: Regularly check all electrical connections to the isolator for tightness and corrosion. Loose or corroded connections can lead to poor performance or failure.
  • Czystość: Keep the isolator unit clean and free from dirt, dust, and moisture. Use a dry cloth to wipe down the exterior.
  • Kontrola okablowania: Periodically inspect the wiring connected to the isolator for any signs of wear, fraying, or damage. Replace damaged wiring immediately.
  • Ochrona środowiska: While rated IP66 for protection against dust and strong water jets, avoid submerging the unit or exposing it to extreme environmental conditions beyond its rating.

No internal user-serviceable parts. Do not attempt to open or repair the unit yourself, especially if it is under warranty.

6. Rozwiązywanie Problemów

If you experience issues with your Smart Isolator Switch, consider the following troubleshooting steps:

  • No Charging of Auxiliary Battery:
    • Sprawdź wszystkie połączenia przewodów pod kątem luzu i korozji.
    • Verify that the main battery is fully charged and the alternator is functioning correctly (outputting sufficient voltagmi).
    • Upewnij się, że pojemność pojazdutage reaches the connection threshold (13.2V) when the engine is running.
  • Main Battery Draining:
    • Confirm that the isolator is properly separating the batteries when the engine is off (voltag(e poniżej 12.7 V).
    • Check for any parasitic draws on the main battery not related to the isolator.
  • Przegrzanie:
    • Ensure the isolator is mounted in a location with adequate airflow.
    • Verify that the current draw does not exceed the 200 Amp ocena.
    • Check for loose connections, which can cause resistance and heat.

If troubleshooting steps do not resolve the issue, contact DB Electrical customer support for further assistance. Do not attempt to repair the unit yourself, especially if it is under warranty.

7. Gwarancja i wsparcie

DB Electrical stands behind the quality of its products. This Smart Isolator Switch is covered by a 1-letnia gwarancja od daty zakupu.

  • Zakres gwarancji: The warranty protects against defects in materials and workmanship under normal use.
  • Proces składania roszczeń: In the rare event that the product does not function flawlessly after installation, please contact DB Electrical customer support. We will take every step to assist you and arrange for a replacement if necessary, within one year of your order.
  • Wykluczenia: The warranty does not cover damage resulting from improper installation, misuse, abuse, unauthorized modifications, or natural disasters. Attempting to repair the tool yourself will void the warranty.

For technical support, warranty claims, or any other inquiries, please refer to the contact information provided with your purchase or visit the official DB Electrical webstrona.

Powiązane dokumenty - 48530-BX

Przedview Inteligentny izolator akumulatorów Cole Hersee 48525 i 48530: instalacja, specyfikacja i akcesoria
Szczegółowe informacje na temat modeli 48525 i 48530 inteligentnego izolatora akumulatorów Cole Hersee, w tym opis działania, instrukcje instalacji, ogólne dane techniczne i kompatybilne akcesoria firmy Littelfuse przeznaczone do systemów z dwoma akumulatorami.
Przedview Zestaw dźwigni blokady Cole Hersee do głównego wyłącznika rozłączającego – instrukcja montażu i produktu
Instrukcja instalacji i szczegółowe informacje o zestawie dźwigni blokady Cole Hersee 24505, przeznaczonym do głównych wyłączników. Zawiera instrukcje bezpieczeństwa i informacje o innych produktach Cole Hersee do zarządzania akumulatorem, takich jak Low Vol.tage Rozłączniki i inteligentne izolatory.
Przedview Cole Hersee 24505 Lockout Lever Kit for Master Disconnect Switch Installation Guide
This document provides installation instructions for the Cole Hersee 24505 Lockout Lever Kit, designed to secure master disconnect switches in the 'Off' position for safety lockout procedures. It details the kit contents and step-by-step installation process.
Przedview GEBE Ersatzteilkatalog für Lichtmaschinen 2018/2019
Umfassender Katalog von GEBE für Lichtmaschinen-Ersatzteile (2018/2019). Enthält detallierte Listen von Kohlebürsten, Reglern, Gleichrichtern und mehr. Ermöglicht die einfache Suche über den GEBE-Compass.
Przedview Instrukcja obsługi projektora Optoma DLP
Kompleksowa instrukcja obsługi projektorów DLP Optoma, obejmująca kwestie bezpieczeństwa, konfiguracji, obsługi, regulacji obrazu, zaawansowanych funkcji, rozwiązywania problemów i specyfikacji.
Przedview Руководство пользователя проектора Optoma DLP
Подробное руководство пользователя для проектора Optoma DLP, охватывающее установку, настройку, использование, technika характеристики i устранение неполадок.