1. Wprowadzenie
This manual provides detailed instructions for the safe and efficient use of your Artemide Cadmo LED Wall Lamp, Model 1373028A. Please read this manual thoroughly before installation and operation, and retain it for future reference. This product is designed for indoor use only.
Ważne informacje dotyczące bezpieczeństwa: Always disconnect power before installation, maintenance, or bulb replacement. Installation should be performed by a qualified electrician in accordance with local electrical codes.
2. Zawartość opakowania
Przed rozpoczęciem instalacji sprawdź, czy wszystkie komponenty są obecne:
- Artemide Cadmo LED Wall Lamp osprzęt
- Sprzęt montażowy (śruby, kotwy ścienne)
- Instrukcja obsługi (ten dokument)
- Note: GU10 LED bulbs are not included and must be purchased separately.
3. Specyfikacje produktu
| Marka: | Artemid |
| Numer modelu: | 1373028A |
| Typ źródła światła: | LED-T (Non Integrated) |
| Podstawa żarówki: | GU10 |
| Zalecane Lamp Moc: | 2 x 7W GU10 (Max 2 x 10W GU10) |
| Tomtage: | 120 wolty |
| Typ sterowania: | Dimmable 2-Wire (Compatible with App/Remote Control) |
| Tworzywo: | Metal, szkło (klosz) |
| Kolor: | White (Fixture), White (Shade) |
| Typ montażu: | Montaż ścienny |
| Zastosowanie wewnątrz/na zewnątrz: | Tylko wewnątrz |
| Cechy szczególne: | Dimmable, Reflector in optic aluminum |
| Kod UPC: | 741813201290 |
4. Instalacja i konfiguracja
Zanim zaczniesz: Ensure the power supply to the installation area is turned off at the circuit breaker. Consult a qualified electrician if you are unsure about any steps.
4.1 Wymagane narzędzia
- Śrubokręt (krzyżakowy i/lub płaski)
- Szczypce boczne
- Taśma izolacyjna
- Drill (if wall anchors are needed)
- Ołówek
- Poziom
4.2 Montaż Urządzenia
- Wyłącz zasilanie: Locate the circuit breaker controlling the light switch for the installation area and turn it off. Verify power is off using a voltagtester.
- Przygotuj powierzchnię montażową: Mark the desired mounting location on the wall. Ensure it is structurally sound and can support the fixture's weight.
- Zainstaluj wspornik montażowy: Attach the fixture's mounting bracket to the wall using the provided screws and wall anchors (if necessary). Use a level to ensure it is straight.
- Połączenia elektryczne: Carefully connect the electrical wires from the wall to the fixture's wires.
- Connect the live (black) wire from the wall to the live wire of the fixture.
- Connect the neutral (white) wire from the wall to the neutral wire of the fixture.
- Connect the ground (green or bare copper) wire from the wall to the ground wire of the fixture.
- Bezpieczne mocowanie: Carefully align the fixture with the mounting bracket and secure it in place using the provided screws. Ensure no wires are pinched.
4.3 Installing GU10 LED Bulbs
The Artemide Cadmo lamp requires two GU10 LED bulbs (not included). Ensure the bulbs are rated for 120V and do not exceed 10W each.
- Gently insert the GU10 bulb into the socket.
- Twist the bulb clockwise until it is securely seated in the socket.
- Repeat for the second bulb.

Figure 1: Artemide Cadmo LED Wall Lamp installed, showcasing its upward and downward light emission.
5. Instrukcja obsługi
After successful installation and bulb insertion, you can operate your Artemide Cadmo LED Wall Lamp.
5.1 Włączanie/wyłączanie
Restore power at the circuit breaker. Use the wall switch connected to the fixture to turn the lamp włączony lub wyłączony.
5.2 Funkcjonalność ściemniania
This fixture supports 2-wire dimming. If connected to a compatible dimmer switch, you can adjust the light intensity. Ensure your dimmer switch is suitable for LED lighting.
Lamp is also compatible with App and Remote Control methods for dimming, provided the appropriate smart home system and GU10 smart bulbs are used.
6. Pielęgnacja i konserwacja
Regular maintenance ensures the longevity and optimal performance of your Artemide Cadmo LED Wall Lamp.
6.1 Czyszczenie
- Zawsze wyłączaj zasilanie do urządzenia przed czyszczeniem.
- Przetrzyj powierzchnie zewnętrzne miękką, suchą lub lekko wilgotną szmatką.amp płótno.
- Do not use abrasive cleaners, solvents, or polishes, as these can damage the finish.
- Przed przywróceniem zasilania należy upewnić się, że urządzenie jest całkowicie suche.
6.2 Wymiana żarówki
When a GU10 LED bulb reaches the end of its life:
- Wyłącz zasilanie przy wyłączniku.
- Jeśli żarówka była niedawno używana, odczekaj, aż całkowicie ostygnie.
- Gently twist the old GU10 bulb counter-clockwise to remove it from the socket.
- Insert a new GU10 LED bulb (max 10W) by aligning the pins and twisting clockwise until secure.
- Przywróć zasilanie za pomocą wyłącznika obwodu.

Rysunek 2: Profesjonalizm bocznyfile of the Artemide Cadmo LED Wall Lamp, illustrating its sleek design.
7. Rozwiązywanie Problemów
If you encounter issues with your Artemide Cadmo LED Wall Lamp, zapoznaj się z poniższymi typowymi problemami i rozwiązaniami:
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Lamp nie włącza się. |
|
|
| Lamp migocze lub przyciemnia się nierównomiernie. |
|
|
| Moc światła jest zbyt niska. |
|
|
If these steps do not resolve the issue, please contact Artemide customer support or a qualified electrician.
8. Gwarancja i wsparcie
For information regarding the product warranty, please refer to the documentation provided at the time of purchase or visit the official Artemide webWarunki gwarancji mogą się różnić w zależności od regionu i sprzedawcy.
For technical support, replacement parts, or further assistance, please contact Artemide customer service directly. Contact information can typically be found on the manufacturer's webwitryny lub opakowania produktu.
Oficjalny Artemide Webstrona: www.artemide.com