diymore 11286400-00a4-4719-befa-ff5839e3bcaf

Instrukcja obsługi cyfrowego woltomierza i amperomierza diymore 0.28" DC 100V 10A

Model: 11286400-00a4-4719-befa-ff5839e3bcaf

1. Wprowadzenie

This manual provides detailed instructions for the installation, operation, and maintenance of the diymore 0.28" DC 100V 10A Digital Voltmeter Ammeter. This compact device is designed for precise measurement of DC voltage and current in various applications, including automotive, electric vehicles, and other electronic projects.

Five diymore 0.28 inch digital volt-amp meters with blue and green displays

Image 1.1: Five diymore 0.28" Digital Voltmeter Ammeters. These meters simultaneously display voltage in blue and current in green, providing clear readings for various DC applications.

2. Funkcje produktu

  • Podwójny wyświetlacz: Jednoczesne wyświetlanie objętościtage and current on a 0.28" digital tube with blue (voltage) and green (current) LEDs.
  • Szeroki zakres pomiarowy: Mierzy objętość DCtage from 0V to 100V and DC current from 0A to 10A.
  • Objętość operacyjnatage: Requires a DC input voltage between 4V and 30V for internal operation.
  • Wysoka dokładność: Aktualne i tomtage measurement accuracy of 1% (±1 digit).
  • Kompaktowa konstrukcja: Miniaturized panel-mount design suitable for integration into various projects.
  • Zastosowania: Ideal for battery monitoring in automotive, electric cars, motorcycles, and general electronic circuit testing.
Close-up of a single diymore digital volt-amp meter with blue voltage and green current display

Image 2.1: A single diymore digital voltmeter ammeter. The clear 0.28" LED display shows voltage in blue and current in green, ensuring easy readability.

3. Specyfikacje techniczne

ParametrWartość
Tomtage Zakres pomiarowyPrąd stały 0–100 V
Aktualny zakres pomiarowyDC 0 - 10A
Typ wyświetlacza0.28" Digital Tube, 3 Bits Dual LED
Kolor wyświetlaczaBlue (Voltage), Green (Current)
Objętość roboczatage (Meter Power)DC 4 - 30V (Max 30V)
Prąd roboczy≤20mA
Dokładność pomiaru1% (±1 digit)
Tomtage Rozdzielczość0.1 V
Aktualna rozdzielczość0.01A
Częstotliwość odświeżaniaApproximately 300ms / time
Długość kabla15cm
Wymiary48mm x 29mm x 26mm
Temperatura pracy-10°C do +65°C

4. Informacje dotyczące bezpieczeństwa

Please read and understand all safety instructions before installing or operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the product or other equipment.

  • Zasilanie: Upewnij się, że objętość roboczatage for the meter (DC 4-30V) is strictly adhered to. Exceeding 30V will damage the meter.
  • Biegunowość: Always observe correct polarity when connecting the power supply and measurement leads. Incorrect connections can cause damage.
  • Aktualny pomiar: For current measurement, the meter uses a shunt. Ensure the load common is correctly connected relative to the power supply common, especially for higher currents.
  • Izolacja: Ensure all connections are properly insulated to prevent short circuits.
  • Środowisko: Do not expose the meter to excessive moisture, dust, or extreme temperatures outside its operating range.
  • Profesjonalna instalacja: If you are unsure about any aspect of the installation, consult a qualified electrician or electronics technician.

5. Konfiguracja i okablowanie

The diymore digital voltmeter ammeter requires careful wiring for both its power supply and the circuit under measurement. Refer to the wiring diagram below for proper connection.

5.1. Schemat okablowania powyżejview

Wiring diagram for diymore digital voltmeter ammeter showing connections for power supply and load

Image 5.1: Detailed wiring diagram for the diymore voltmeter ammeter. It illustrates the connections for the meter's power supply (DC 4-30V) and the circuit being measured (DC 0-100V, 0-10A load).

The meter typically comes with two sets of wires:

  • Thin Wires (Power Supply for Meter):
    • Red (thin): Positive (+) terminal for the meter's internal power supply (DC 4-30V).
    • Black (thin): Negative (-) terminal for the meter's internal power supply.
    • Yellow (thin): Tomtage measurement input positive (+). This wire connects to the positive side of the circuit you want to measure voltage z.
  • Thick Wires (Current Measurement):
    • Red (thick): Current input positive (+). This connects to the positive side of the load.
    • Czarny (gruby): Current input negative (-). This connects to the negative side of the load, completing the series circuit for current measurement.

Ważna uwaga: The thin black wire (meter power negative) and the thick black wire (current measurement negative) are often internally connected or share a common ground. Ensure your wiring configuration respects this to avoid short circuits or incorrect readings. The current measurement must be done in series with the load.

5.2. Kroki instalacji

  1. Prepare Panel Cutout: Create an appropriate rectangular cutout in your panel for the meter. The dimensions are approximately 48mm x 29mm.
  2. Wstaw miernik: Gently push the meter into the cutout. The retaining clips on the sides will secure it. If the clips are too tight, you may need to carefully remove the PCB from the casing, insert the empty casing, and then reinsert the PCB.
  3. Connect Power (Thin Wires):
    • Połącz thin red wire to the positive (+) terminal of your DC 4-30V power source.
    • Połącz thin black wire to the negative (-) terminal of your DC 4-30V power source.
  4. Połącz Voltage Measurement (Thin Yellow Wire):
    • Połącz thin yellow wire to the positive (+) point of the circuit where you want to measure voltage.
  5. Connect Current Measurement (Thick Wires):
    • Disconnect the positive supply line to your load.
    • Połącz thick red wire to the positive supply side (where the positive supply line was disconnected from the load).
    • Połącz thick black wire to the positive input of your load. This places the ammeter in series with the load.
  6. Sprawdź połączenia: Double-check all connections for correct polarity and secure contact before applying power.
Close-up of the two-pin and three-pin connectors for the diymore digital meter

Obraz 5.2: Zbliżenie view of the connectors. The smaller connector typically handles the meter's power and voltage sensing, while the larger connector is for current measurement.

6. Instrukcja obsługi

Once properly wired and powered, the diymore digital voltmeter ammeter will automatically display the measured voltagi aktualne.

  • Tomtage Wyświetlacz: The upper display, typically in blue, shows the DC voltage w woltach (V).
  • Bieżący wyświetlacz: The lower display, typically in green, shows the DC current in Ampjest (A).
  • Dokładność odczytu: Readings are accurate to 1% (±1 digit). For precise applications, consider calibration as described in Section 7.
  • Częstotliwość odświeżania: The display updates approximately every 300 milliseconds.

7. Kalibracja

Some units may require calibration for optimal accuracy. The meter typically features two small potentiometers (trim pots) on the Printed Circuit Board (PCB) for adjusting voltage i aktualne odczyty.

Wewnętrzny view of the diymore digital meter showing the PCB and components

Obraz 7.1: Wewnętrzny view of the diymore digital meter. The PCB contains various components, including small potentiometers (trim pots) that can be used for calibration of voltage i aktualne odczyty.

7.1. Procedura kalibracji

  1. Access PCB: Carefully remove the meter from its casing to access the PCB.
  2. Identify Trim Pots: Locate the two small potentiometers on the PCB. One is for voltage calibration, and the other is for current calibration. They may be labeled or identifiable by their proximity to voltage/current sensing circuitry.
  3. Connect Reference Meter: Connect a known accurate reference voltmeter and ammeter in parallel and series, respectively, with the circuit being measured by the diymore meter.
  4. Dostosuj głośnośćtage: Apply a stable DC voltage (e.g., 12V or 24V) within the meter's range. Using a small screwdriver, carefully turn the voltage trim pot until the diymore meter's voltage reading matches the reference voltmeter.
  5. Dostosuj prąd: Apply a stable DC current (e.g., 1A or 5A) through the diymore meter. Using a small screwdriver, carefully turn the current trim pot until the diymore meter's current reading matches the reference ammeter.
  6. Ponowny montaż: Once calibrated, carefully reassemble the meter into its casing.

Ostrożność: Exercise extreme care when handling the exposed PCB to avoid electrostatic discharge or damage to components.

8. Konserwacja

The diymore digital voltmeter ammeter is designed for low maintenance. Follow these guidelines to ensure its longevity:

  • Czyszczenie: Do czyszczenia wyświetlacza i obudowy należy używać miękkiej, suchej ściereczki.asing. Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Ochrona środowiska: Keep the device away from direct sunlight, excessive heat, moisture, and corrosive environments.
  • Integralność połączenia: Okresowo sprawdzaj połączenia przewodów, aby mieć pewność, że są solidne i nie ulegają korozji.

9. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
No display / Meter not powering on
  • Niewłaściwe napięcie zasilaniatage (outside DC 4-30V).
  • Incorrect polarity for meter power wires (thin red/black).
  • Loose or faulty power connections.
  • Meter is damaged.
  • Verify power supply is within DC 4-30V.
  • Check thin red and black wire polarity.
  • Sprawdź, czy wszystkie połączenia są bezpieczne.
  • Replace meter if damaged.
Niedokładna objtage or current readings
  • Meter requires calibration.
  • Incorrect wiring for measurement.
  • Zakłócenia zewnętrzne.
  • Wykonaj kalibrację zgodnie z opisem w rozdziale 7.
  • Review wiring diagram (Section 5.1) for correct connections.
  • Ensure meter is not near strong electromagnetic fields.
Current reading is 0A or incorrect
  • Ammeter not wired in series with the load.
  • Thick red/black wires incorrectly connected.
  • No current flowing through the load.
  • Ensure the thick wires are in series with the positive line to the load.
  • Verify thick wire polarity and connection points.
  • Check if the load is functioning and drawing current.
Tomtage reading is 0V or incorrect
  • Thin yellow wire not connected to the voltagŹródło.
  • Brak objętościtage present at the measurement point.
  • Connect the thin yellow wire to the positive point of voltagpomiar.
  • Zweryfikuj objętośćtage presence with a multimeter.

10. Gwarancja i wsparcie

diymore products are designed for reliability and performance. While specific warranty details are not provided in this manual, standard return policies typically apply for products purchased through authorized retailers.

For technical assistance, troubleshooting beyond this manual, or inquiries regarding product functionality, please contact diymore customer support through your point of purchase or visit the official diymore brand store online.

Zasoby internetowe:

Powiązane dokumenty - 11286400-00a4-4719-befa-ff5839e3bcaf

Przedview Woltomierz i amperomierz DC Diymore 0.28 cala z podwójnym wyświetlaczem, 100 V, 10 A – instrukcja obsługi
Zwięzły przewodnik po okablowaniu i obsłudze woltomierza i amperomierza DC Diymore z podwójnym wyświetlaczem 0.28 cala, umożliwiający pomiar do 100 V i 10 A. Zawiera schematy okablowania dla różnych konfiguracji zasilania. Obsługuje wejście zasilania DC 4-30 V i zakres pomiaru DC 0-100 V.
Przedview Instrukcja obsługi Diymore Adjustable VoltageRegulator
Szczegółowa instrukcja obsługi i ustawienia parametrów regulatora głośności Diymoretage Regulator DC Buck Boost Converter, obejmujący zakrestagi bieżącej regulacji, ustawień zabezpieczeń i kalibracji.
Przedview 5918 Tom cyfrowytage Instrukcja obsługi miernika
Instrukcja obsługi modelu 5918 Digital Voltage Meter firmy diymore. Zawiera parametry produktu, opis, kluczowe funkcje i szczegółowe instrukcje konfiguracji dla różnych typów baterii (litowych, żelazowo-litowych, kwasowo-ołowiowych) oraz niestandardowej objętości.tage/ustawienia podświetlenia.
Przedview Moduł przekaźnika Bluetooth 4-kanałowy diymore DC 5V/12V – sterowanie inteligentnym domem
Szczegółowe ponadview Moduł przekaźnikowy Bluetooth 4-kanałowy Diymore DC 5V/12V do inteligentnej automatyki domowej. Zdalne sterowanie za pomocą aplikacji mobilnej, moduł Bluetooth JDY-31 i przekaźniki 10A.
Przedview Cyfrowy regulator temperatury Diymore STC-3008 – podwójny wyświetlacz NTC
Szczegółowa specyfikacja i instrukcja obsługi cyfrowego regulatora termostatu Diymore STC-3008. Wyposażony w podwójny wyświetlacz, czujniki NTC, kompatybilny z AC 110 V/230 V oraz instrukcje dotyczące konfiguracji, obsługi i bezpieczeństwa ogrzewania/chłodzenia.
Przedview Instrukcja montażu zestawu DIY do obudowy oscyloskopu DSO 138 DIYMORE
Instrukcja krok po kroku instalacji zestawu DIYMORE DSO 138 do samodzielnego montażu obudowy oscyloskopu. Dowiedz się, jak złożyć akrylową obudowę oscyloskopu DSO 138.