Leviton LB260-GS

Instrukcja obsługi wyłącznika różnicowoprądowego Leviton 60A z wtyczką 2-biegunową Smart GFCI (LB260-GS)

Model: LB260-GS

1. Wprowadzenie

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Leviton LB260-GS 60A 2-Pole Plug-On Smart GFCI Branch Circuit Breaker. Please read all instructions carefully before proceeding with installation or use.

The Leviton LB260-GS is a Smart Ground Fault Circuit Interrupter (GFCI) branch circuit breaker designed for use in Leviton Load Centers. It features hydraulic magnetic technology for reliable operation across a wide temperature range and integrates with the My Leviton app for enhanced monitoring and control.

2. Informacje dotyczące bezpieczeństwa

WARNING: RISK OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.

  • This product must be installed and serviced by qualified electrical personnel only.
  • Turn off all power to the electrical panel before working on or installing the circuit breaker.
  • Zawsze używaj objtage detector to confirm power is off before touching any wires or components.
  • Należy przestrzegać wszystkich lokalnych i krajowych przepisów i regulacji dotyczących instalacji elektrycznych.
  • Nie używaj tego urządzenia, jeśli wygląda na uszkodzone.

Nieprzestrzeganie tych instrukcji może skutkować śmiercią lub poważnymi obrażeniami.

3. Koniec produktuview

The Leviton LB260-GS is a 2-pole, 60-Amp Smart GFCI circuit breaker. It is designed to protect against ground faults, which can cause severe electrical shock. Its hydraulic magnetic trip technology ensures consistent performance from -40°C to 85°C (-40°F to 185°F).

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, front view

Obraz 3.1: Przód view of the Leviton LB260-GS Smart GFCI Circuit Breaker. Shows the ON/OFF switch, 60 Amp rating, GFCI indicator, and wireless communication symbol.

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, side view

Obraz 3.2: Strona view of the Leviton LB260-GS Smart GFCI Circuit Breaker, illustrating its compact design for plug-on installation.

Leviton LB260-GS 60A 2-Pole Smart GFCI Circuit Breaker, rear view showing bus connections

Obraz 3.3: Tył view of the Leviton LB260-GS Smart GFCI Circuit Breaker, highlighting the plug-on bus connections for easy installation into a Leviton Load Center.

Główne cechy:

  • Inteligentna integracja: Connects with the My Leviton app for energy consumption data, enhanced safety alerts, and remote control.
  • Łatwa instalacja: Revolutionary plug-on design allows for quick and tool-free installation into Leviton Load Centers.
  • Hydraulic Magnetic Technology: Ensures precise and reliable tripping characteristics across a wide temperature range without derating.
  • Zwiększone bezpieczeństwo: Features patented reset lockout technology, preventing reset if ground fault protection is compromised.

4. Konfiguracja i instalacja

Professional installation by a qualified electrician is required.

  1. Przygotuj Centrum Załadunku: Ensure all power to the Leviton Load Center is turned OFF at the main service disconnect. Verify with a voltagtester.
  2. Połączenia przewodowe: The Leviton Load Center design allows branch phase and neutral connections to be made directly on the panel bus bars without the circuit breaker present. Land the branch circuit wires (hot and neutral) to the appropriate terminals on the load center bus.
  3. Install the Breaker: Align the LB260-GS circuit breaker with the desired position on the load center bus. Firmly push the breaker onto the bus until it clicks into place. No additional wiring to the breaker itself is required.
  4. Uziemienie: Connect the ground wire from the branch circuit to the ground bar in the load center.
  5. Sprawdź instalację: Double-check all connections for tightness and proper seating.
  6. Przywróć zasilanie: Po zakończeniu instalacji i jej sprawdzeniu przywróć zasilanie w centrum obciążenia.

For a visual guide on installing Leviton Load Centers and circuit breakers, please refer to the video below:

Wideo 4.1: An instructional video demonstrating the installation process for Leviton Load Centers and their plug-on circuit breakers, including wiring and breaker placement.

5. Instrukcja obsługi

Obsługa ręczna:

  • WŁĄCZANIE: Push the breaker handle firmly to the "ON" position.
  • Wyłączanie: Push the breaker handle firmly to the "OFF" position.
  • Resetowanie wyłączonego wyłącznika: If the breaker trips, the handle will move to a center position. To reset, first push the handle firmly to the "OFF" position, then push it to the "ON" position. If the breaker immediately trips again, there may be an electrical fault that needs to be addressed.

GFCI Test and Reset:

The GFCI function should be tested monthly to ensure proper operation.

  1. Upewnij się, że wyłącznik jest w pozycji „ON”.
  2. Press the "TEST" button on the face of the breaker. The breaker should immediately trip to the center position.
  3. To restore power, push the handle firmly to the "OFF" position, then to the "ON" position.
  4. If the breaker does not trip when the "TEST" button is pressed, or if it does not reset, the GFCI function may be faulty. Contact a qualified electrician for inspection and replacement.

Smart Features (My Leviton App):

The LB260-GS integrates with the My Leviton app, providing advanced functionality:

  • Monitorowanie energii: View real-time and historical energy consumption data for the circuit.
  • Zdalne sterowanie: Turn the breaker ON or OFF remotely via the app.
  • Powiadomienia: Receive alerts for electrical anomalies, tripped breakers, or other status changes.
  • Autotest: The smart breaker performs self-tests and reports status to the app.

Refer to the My Leviton app documentation for detailed instructions on connecting and utilizing smart features.

6. Konserwacja

  • Miesięczny test GFCI: Perform the GFCI test as described in Section 5.
  • Kontrola wizualna: Periodically inspect the circuit breaker for any signs of physical damage, discoloration, or loose connections. If any issues are observed, contact a qualified electrician.
  • Czyszczenie: Keep the breaker and surrounding area clean and free of dust and debris. Do not use liquid cleaners directly on the breaker.

7. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Częste wyzwalanie wyłączników.Overload, short circuit, or ground fault.Reduce load on the circuit. Check for damaged appliances or wiring. If it's a GFCI trip, check for ground faults in connected equipment. Contact an electrician if the problem persists.
Breaker does not reset after tripping.Persistent fault (overload, short circuit, or ground fault) or internal breaker damage.Ensure the handle is pushed fully to "OFF" before attempting to reset to "ON". If it still won't reset, a fault is likely present. Do not force the breaker. Contact a qualified electrician.
Przycisk testowy GFCI nie wyzwala wyłącznika.Uszkodzony mechanizm GFCI.The breaker may be defective. It must be replaced by a qualified electrician.
No data in My Leviton app / Breaker not connecting.Network issue, app configuration error, or data hub issue.Ensure your Wi-Fi network is active and the Leviton data hub (if applicable) is connected. Check app settings and follow in-app troubleshooting guides.

For issues not covered here, contact Leviton customer support or a qualified electrician.

8. Specyfikacje

AtrybutSzczegół
MarkaLewiton
Numer modeluLB260-GS
Obecna ocena60 Amps
Liczba słupów2
Tomtage120 / 240 VAC
Typ wyłącznika automatycznegoGFCI (wyłącznik różnicowoprądowy)
Trip TechnologyHydraulic Magnetic
Ocena przerwania10 tys.
Typ montażuPanel Mounting (Plug-On)
Temperatura pracy-40°C do 85°C (-40°F do 185°F)
Wymiary4 x 2.5 x 3.9 cale (w przybliżeniu)
Waga13.6 uncji
UPC078477815342

9. Gwarancja i wsparcie

Gwarancja:

This Leviton product is covered by a 10-roczna ograniczona gwarancja. For full details regarding warranty terms and conditions, please refer to the official Leviton warranty statement available on their webodwiedź witrynę lub skontaktuj się z działem obsługi klienta.

Obsługa klienta:

For technical assistance, product information, or warranty claims, please contact Leviton customer support through their official webstronę internetową lub dane kontaktowe znajdujące się na opakowaniu produktu.

You can visit the official Leviton webwitryna zawierająca więcej zasobów: www.leviton.com

Powiązane dokumenty - LB260-GS

Przedview Instrukcja montażu gniazdka GFCI Leviton GFNT1-DIN/GFNT2-DIN na szynie DIN
Kompleksowy przewodnik po instalacji i testowaniu gniazd GFCI GFNT1-DIN i GFNT2-DIN firmy Leviton do montażu na szynie DIN, zawierający instrukcje dotyczące okablowania, środki ostrożności i rozwiązywania problemów.
Przedview Instrukcja instalacji i obsługi gniazda Leviton GFCI z portami USB
Kompleksowy przewodnik dotyczący instalacji i obsługi gniazdek Leviton GFCI z portami USB, obejmujący instrukcje dotyczące okablowania, ostrzeżenia dotyczące bezpieczeństwa, procedury testowe i informacje gwarancyjne.
Przedview Instrukcja instalacji i testowania gniazdka Leviton GFCI
Kompleksowy przewodnik na temat instalacji i testowania gniazdka GFCI Leviton SmartLock Pro, obejmujący instrukcje dotyczące okablowania, środki ostrożności i wskazówki dotyczące rozwiązywania problemów.
Przedview Instalacja i testowanie inteligentnego gniazdka GFCI Leviton: kompleksowy przewodnik
Instrukcja krok po kroku dotycząca instalacji i testowania gniazd Leviton Smart GFCI (modele D2GF1, D2GF2). Dowiedz się więcej o działaniu GFCI, okablowaniu, rozwiązywaniu problemów i środkach ostrożności.
Przedview Leviton Load Center Phase Maps Installation Guide
This guide provides phase map illustrations to simplify the installation of the Leviton Whole Home Energy Monitor (LWHEM). It details where to terminate power wires and mount the Smart Mains Metering Accessory CTs for monitoring whole-home energy consumption.
Przedview Instrukcja montażu obudowy centrum załadunku Leviton
Szczegółowa instrukcja montażu obudów rozdzielnic Leviton Load Center, modele LP2xx, LP3xx, LP4xx i LP6xx. Obejmuje ona kwestie bezpieczeństwa, wyłamywanie wyłamywanych otworów, montaż, okablowanie, instalację wyłącznika obwodu odgałęzionego oraz montaż pokrywy.