Everbilt HPEBAU33

Everbilt 1/3 HP Automatic Utility Pump HPEBAU33 Instruction Manual

1. Koniec produktuview

The Everbilt 1/3 HP Automatic Utility Pump HPEBAU33 is designed for efficient water removal from various low-lying areas such as crawl spaces and window wells. This submersible pump features an integrated mini-float switch for automatic operation, activating when water levels reach approximately 1-1/2 inches and deactivating when levels drop to about 1/8 inch. It is important to note that this pump is not intended for permanent installation, nor should it be used as a sump pump or in sewage/septic systems.

Everbilt 1/3 HP Automatic Utility Pump HPEBAU33

Rysunek 1: Everbilt 1/3 HP Automatic Utility Pump HPEBAU33. This image displays the pump's compact design, including the power cord connection and the threaded discharge outlet.

2. Informacje dotyczące bezpieczeństwa

Read and understand all safety instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.

3. Zawartość opakowania

Sprawdź, czy po rozpakowaniu wszystkie elementy są obecne i nieuszkodzone:

4. Specyfikacje

FunkcjaSpecyfikacja
Numer modeluHPEBAU33
Moc w koniach mechanicznych1/3 KM (0.33 KM)
Typ zasilaniaPrąd przemienny
Tomtage115 V
Ampwymazać3 A
Maximum Discharge Flow (0 ft. head)1620 Gallons per Hour (27 GPM)
Maximum Discharge Flow (10 ft. head)1260 Gallons per Hour (21 GPM)
Maksymalna wysokość podnoszenia28 stóp.
Pump Switch TypeFloat Switch (Automatic)
Turn-On Water LevelApproximately 1-1/2 in.
Turn-Off Water LevelApproximately 1/8 in.
Wylot wylotowy1-1/4 in. MIP (Male Iron Pipe)
Długość przewodu10 stóp.
Materiał obudowyTermoplastyczny
Maksymalna temperatura robocza95°F (35°C)
Minimalna temperatura pracy33°F (0.5°C)
Wymiary produktu (dł. x szer. x wys.)12" x 8" x 6"
Waga przedmiotu8.8 funtów

5. Instrukcje konfiguracji

  1. Umieszczenie: Position the pump on a stable, level surface in the area where water removal is needed. Ensure the pump's intake screen is clear of debris. The pump is suitable for crawl spaces, window wells, and other low-lying areas.
  2. Połączenie wylotowe:
    • For standard garden hoses: Attach the provided 3/4 inch garden hose adapter to the pump's 1-1/4 inch MIP discharge outlet. Then, connect a standard garden hose to the adapter.
    • For larger discharge hoses: Connect a 1-1/4 inch discharge hose directly to the pump's 1-1/4 inch MIP discharge outlet. The included 1-1/4 inch check valve should be installed in the discharge line to prevent backflow.
    Ensure all connections are secure to prevent leaks. Route the discharge hose to a suitable drainage area, away from the pump's location, to prevent water recirculation.
  3. Podłączenie zasilania: Plug the 10 ft. power cord into a grounded 115V AC electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.
  4. Kontrola wstępna: Before operation, ensure the pump is fully submerged in water or will be submerged once water levels rise. The float switch requires water to operate correctly.

Ważna uwaga: This pump is not designed for permanent installation and should not be used as a primary sump pump for continuous, long-term operation in a sump pit. It is intended for temporary water removal applications.

6. Instrukcja obsługi

The Everbilt HPEBAU33 pump operates automatically based on water levels detected by its integrated mini-float switch.

  1. Działanie automatyczne: Once plugged in and placed in water, the pump will automatically turn on when the water level reaches approximately 1-1/2 inches. It will continue to pump water until the level drops to approximately 1/8 inch, at which point the pump will automatically turn off.
  2. Continuous Readiness: The pump can be left plugged in indefinitely, allowing it to activate automatically whenever water accumulates to the turn-on level.
  3. Monitorowanie: Periodically check the pump's operation and the discharge area to ensure proper function and prevent blockages.

7. Konserwacja

Regularna konserwacja zapewnia optymalną wydajność i wydłuża żywotność pompy.

8. Rozwiązywanie Problemów

Jeśli masz problemy z pompą, zapoznaj się z poniższymi typowymi problemami i ich rozwiązaniami:

ProblemMożliwa przyczynaRozwiązanie
Pompa nie włącza się.No power; float switch obstructed; water level too low; clogged intake.Check power connection and GFCI. Ensure float switch moves freely. Verify water level is above 1-1/2 inches. Clean intake screen.
Pompa pracuje, ale woda nie jest wypompowywana lub przepływ jest zbyt mały.Discharge hose kinked or blocked; pump not fully submerged; air lock; clogged intake.Check and clear discharge hose. Ensure pump is fully submerged. Briefly lift and lower pump to release air. Clean intake screen.
Pompa nie wyłącza się.Float switch obstructed or stuck in "on" position; debris preventing water from draining below turn-off level.Unplug pump and check float switch for obstructions. Ensure area around pump is clear for water to drain.
Pompa wydaje nietypowy dźwięk.Zanieczyszczenia w wirniku; pompa pracuje na sucho.Disconnect power, inspect and clear impeller. Ensure pump is always submerged during operation.

9. Gwarancja i wsparcie

This Everbilt pump is covered by a Roczna gwarancja producenta od daty zakupu. Niniejsza gwarancja obejmuje wady materiałowe i wykonawcze przy normalnym użytkowaniu.

For warranty claims, technical assistance, or replacement parts, please contact Everbilt customer support. Keep your purchase receipt as proof of purchase.

Please refer to the official Everbilt website or your product packaging for the most current contact information and detailed warranty terms.

Powiązane dokumenty - HPEBAU33

Przedview Instrukcja użytkowania i konserwacji automatycznej pompy zanurzeniowej Everbilt 1/3 KM
Kompleksowa instrukcja użytkowania i konserwacji automatycznej pompy zanurzeniowej Everbilt o mocy 1/3 KM (model EBAU33). Obejmuje ona informacje na temat wydajności, bezpieczeństwa, instalacji, obsługi, konserwacji i rozwiązywania problemów.
Przedview Everbilt 2-in-1 Utility Pump Quick Start Guide
A quick start guide for the Everbilt 2-in-1 Utility Pump (Model UTA02510), providing instructions for setup, operation, and safety in both English and Spanish.
Przedview Pompa zanurzeniowa do pokryw basenowych Everbilt 1/4 KM: Instrukcja użytkowania i konserwacji
Kompleksowy przewodnik po pompie zanurzeniowej do basenów Everbilt o mocy 1/4 KM, obejmujący montaż, obsługę, konserwację, bezpieczeństwo i rozwiązywanie problemów. Dowiedz się, jak efektywnie użytkować i dbać o pompę basenową Everbilt.
Przedview Krótki przewodnik po zatapialnej pompie użytkowej Everbilt
A quick reference guide for the Everbilt Submersible Utility Pump, providing essential installation and operation instructions. Learn how to connect the hose, position the pump, prime it, and connect to power.
Przedview Everbilt Submersible Sump Pump Use and Care Guide | SP03302EP, SP05002VD
This comprehensive guide provides essential information for the safe and effective use, care, and maintenance of Everbilt submersible sump pumps, models SP03302EP and SP05002VD. Learn about performance specifications, assembly, operation, troubleshooting, and warranty details.
Przedview Instrukcja montażu akcesoriów hydroizolacyjnych Everbilt
Kompleksowy przewodnik montażu akcesoriów hydroizolacyjnych Everbilt, szczegółowo opisujący przygotowanie podłoża, wykonanie szwów, uszczelnianie narożników i rur oraz ostateczne nakładanie płytek w przypadku instalacji wodoodpornych.