1. Wprowadzenie
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the ABB ACS580-01-026A-4 Drive. This industrial drive is designed for various applications requiring precise motor control, offering a robust solution for 400V systems with an 11KW power rating and 25A current capacity, housed in an IP21 rated frame size R2.
Please read this manual thoroughly before attempting any installation or operation to ensure proper functionality and to prevent damage to the equipment or injury to personnel.
2. Informacje dotyczące bezpieczeństwa
OSTRZEŻENIE: Electrical shock hazard. Only qualified personnel should perform installation, commissioning, and maintenance of this equipment. Disconnect all power before servicing.
- Ensure proper grounding of the drive and motor.
- Do not operate the drive with damaged cables or components.
- Zawsze należy przestrzegać lokalnych i krajowych przepisów dotyczących instalacji elektrycznych.
- Protect the drive from moisture, dust, and extreme temperatures.
3. Konfiguracja i instalacja
The ABB ACS580-01-026A-4 Drive is designed for DIN Rail mounting. Ensure adequate ventilation around the unit.
3.1. Montaż
Mount the drive vertically on a DIN rail in an enclosure that provides the specified IP21 protection. Allow sufficient clearance for cooling air flow above and below the unit.

Rycina 3.1: Przód view of the ABB ACS580-01-026A-4 Drive, showing its compact design and control panel area. This image illustrates the overall physical appearance of the drive unit.
3.2. Okablowanie
Connect the main power supply (400V AC) to the designated input terminals. Connect the motor to the output terminals. Ensure all connections are secure and correctly phased. Refer to the wiring diagram provided with the drive for detailed terminal assignments.
- Pobór mocy: L1, L2, L3 (400V AC)
- Moc silnika: U, V, W
- Grunt: Connect to protective earth (PE) terminal.
- Okablowanie sterujące: Connect control signals (e.g., start/stop, speed reference) as per application requirements.
4. Instrukcja obsługi
Once installed and wired, the drive can be configured and operated. The ACS580 series features an intuitive control panel for parameter setting and monitoring.
4.1. Pierwsze uruchomienie
- Sprawdź, czy wszystkie połączenia okablowania są prawidłowe i bezpieczne.
- Apply main power to the drive. The control panel should illuminate.
- Follow the quick setup wizard on the control panel to configure basic motor parameters (e.g., motor nominal voltage, current, frequency, speed).
4.2. Podstawowa obsługa
- Uruchom/zatrzymaj: Use the designated control input (e.g., digital input) or the control panel buttons to start and stop the motor.
- Kontrola prędkości: Adjust the motor speed using the analog input, fieldbus, or control panel potentiometer, depending on configuration.
- Monitorowanie: The control panel displays operational data such as motor speed, current, voltage i kody błędów.
5. Konserwacja
Regular maintenance ensures the longevity and reliable operation of the ABB ACS580-01-026A-4 Drive.
- Czyszczenie: Periodically clean the drive's exterior and cooling fins to prevent dust accumulation, which can impede heat dissipation. Use a soft, dry cloth.
- Kontrola wentylatora: Inspect the cooling fan for proper operation and cleanliness. Replace if noisy or not functioning correctly.
- Kontrola połączenia: Annually, or as needed, verify that all electrical connections are tight and free from corrosion.
- Warunki środowiskowe: Upewnij się, że środowisko pracy mieści się w określonym zakresie temperatury i wilgotności.
6. Rozwiązywanie Problemów
This section provides guidance for common issues encountered during the operation of the drive.
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Napęd się nie włącza | Brak zasilania wejściowego; Przepalony bezpiecznik; Nieprawidłowe okablowanie | Check main power supply; Inspect fuses; Verify wiring connections. |
| Silnik nie uruchamia się | Control signal missing; Parameter misconfiguration; Motor fault | Check control wiring; Review drive parameters; Inspect motor for issues. |
| Błąd nadprądowy | Motor overload; Short circuit in motor/cables; Incorrect acceleration time | Reduce load; Check motor and cables; Increase acceleration time. |
| Przepełnienietagwina | Wysoka głośność wejściowatage; Hamowanie regeneracyjne bez rezystora hamującego | Sprawdź objętość wejściowątage; Install braking resistor if needed. |
For detailed fault codes and advanced troubleshooting, refer to the complete technical manual available on the ABB website or contact ABB technical support.
7. Specyfikacje
Key technical specifications for the ABB ACS580-01-026A-4 Drive:
- Numer modelu: ACS580-01-026A 4
- Marka: WĄTEK
- Wejście Voltage: 400 V prądu zmiennego
- Moc znamionowa: 11 kW
- Aktualna ocena: 25 Amps
- Stopień ochrony IP: IP21
- Rozmiar ramki: R2
- Typ montażu: Montaż na szynie DIN
- Producent: Napędy ABB
8. Gwarancja i wsparcie
This ABB drive comes with a standard manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official ABB webstrona.
For technical support, service, or spare parts, please contact your local ABB representative or visit the ABB support portal: