FrSky R9 MM-OTA

FrSky Access 900MHz Long Range R9 MM-OTA Receiver Instruction Manual

Model: R9 MM-OTA

1. Wprowadzenie

The FrSky Access 900MHz Long Range R9 MM-OTA Receiver is designed to provide extended range and enhanced performance for remote control applications. Utilizing the ACCESS protocol, this receiver offers convenient features such as wireless firmware updates (Over-The-Air) and telemetry data transmission. Its compact and lightweight design makes it suitable for various installations.

2. Informacje dotyczące bezpieczeństwa

Always operate your remote control system responsibly. Failure to follow safety guidelines can result in property damage or injury. Ensure all connections are secure and correct before powering on. Keep the receiver away from moisture, extreme temperatures, and strong electromagnetic fields. Regularly inspect components for damage.

3. Koniec produktuview

The R9 MM-OTA receiver is a miniature 900MHz long-range receiver. It features an Ipex connector for the antenna and multiple ports for connectivity.

FrSky R9 MM-OTA Receiver with antenna

Image 1: FrSky R9 MM-OTA Receiver with its detachable Ipex connector antenna.

Główne cechy:

  • 915MHz (Non-LBT Version) / 868MHz (LBT Version) operation.
  • Miniature size and super lightweight design.
  • Supports Over-The-Air (OTA) firmware updates.
  • Allows for firmware version checking.
  • S.Port enabled for telemetry data transmission (F.Port support available via firmware update).
  • Inverted S.Port enabled.
  • Low latency and high precision.
  • RSSI output available in SBUS.
  • Pojemność bateriitage detection supported.
  • Detachable Ipex connector antenna.

4. Specyfikacje

SpecyfikacjaWartość
Wymiar16 x 10 x 2.8 mm (dł. x szer. x wys.)
Waga0.7g (bez anteny)
Liczba kanałówNon-LBT Version: 4/16CH (Telemetry)
LBT Version: 4/16CH (Telemetry) / 4/16CH (No Telemetry)
Objętość operacyjnatage ZakresPrąd stały 3.5 V – 10 V
Prąd roboczy100mA @ 5V
Zasięg działaniaUp to 10km or above
ZgodnośćR9 series 900MHz module (ACCESS protocol)

5. Konfiguracja

5.1. Instalacja anteny

Carefully connect the detachable Ipex connector antenna to the receiver. Ensure the connection is firm to maintain optimal signal integrity and range.

5.2. Połączenia okablowania

Connect the receiver to your flight controller or other compatible devices using the appropriate ports. The R9 MM-OTA supports S.Port and inverted S.Port for telemetry. Refer to your flight controller's manual for specific wiring diagrams.

5.3. Procedura wiążąca

  1. Power on your transmitter and navigate to the binding menu for your R9M module.
  2. Select the appropriate mode (e.g., ACCESS, D16) and channel range.
  3. Press and hold the F/S (Fail-Safe) button on the R9 MM-OTA receiver while powering it on. The red LED on the receiver will flash, indicating it is in binding mode.
  4. On your transmitter, initiate the binding process. The receiver's LED will turn solid green when binding is successful.
  5. Wyłącz i włącz nadajnik oraz odbiornik, aby sprawdzić połączenie.

Note: Ensure your R9M module and R9 MM-OTA receiver are running compatible firmware versions for successful binding. Firmware updates can be performed wirelessly via OTA.

6. Obsługa

6.1. Telemetry Data Transmission

The R9 MM-OTA receiver supports telemetry data transmission via S.Port. This allows you to monitor various parameters such as receiver signal strength (RSSI) and battery voltage directly on your compatible FrSky transmitter. For F.Port functionality, a specific firmware update is required.

6.2. Over-The-Air (OTA) Firmware Updates

The OTA feature allows for wireless firmware updates of the receiver directly from your compatible FrSky transmitter. This eliminates the need for physical connection to a computer for updates. Consult your transmitter's manual for detailed instructions on performing OTA updates.

6.3. Sprawdzenie wersji oprogramowania sprzętowego

You can check the current firmware version of your R9 MM-OTA receiver wirelessly through your compatible FrSky transmitter. This helps ensure all components are running the latest and compatible software.

7. Konserwacja

The R9 MM-OTA receiver is a robust electronic component. To ensure its longevity and optimal performance:

  • Utrzymuj odbiornik w czystości, wolny od kurzu i zanieczyszczeń.
  • Avoid exposing it to excessive vibrations or physical shock.
  • W przypadku montażu w pomieszczeniu zamkniętym należy zapewnić odpowiednią wentylację, aby zapobiec przegrzaniu.
  • Regularly check antenna connections for tightness and damage.

8. Rozwiązywanie Problemów

8.1. Odbiornik niewiążący

  • Sprawdź zgodność oprogramowania sprzętowego: Ensure both your transmitter's R9M module and the R9 MM-OTA receiver are running compatible firmware versions (e.g., both ACCESS or both ACCST). Firmware updates are often necessary for new products or after major updates.
  • Binding Button Functionality: Verify the F/S button on the receiver is functioning correctly. If it's damaged or unresponsive, binding may fail.
  • Cykl zasilania: Always power cycle both the transmitter and receiver after attempting to bind.
  • Bliskość: During binding, keep the receiver close to the transmitter (within 1 meter).

8.2. Poor Range or Signal Loss

  • Umiejscowienie anteny: Ensure the receiver antenna is positioned optimally, away from carbon fiber, metal, or other signal-blocking materials. Avoid sharp bends in the antenna wire.
  • Uszkodzenie anteny: Inspect the antenna for any cuts, kinks, or damage to the active element. Replace if necessary.
  • Ingerencja: Keep the receiver away from other electronic components that may generate electromagnetic interference (e.g., ESCs, motors, video transmitters).
  • Zasilanie: Verify the receiver is receiving stable power within its specified voltagZakres.

9. Gwarancja i wsparcie

Produkty FrSky objęte są ograniczoną gwarancją na wady materiałowe i wykonawcze. Szczegółowe warunki gwarancji można znaleźć w oficjalnej instrukcji obsługi FrSky. website or contact your local distributor. For technical support, visit the FrSky support portal or contact their customer service.

Powiązane dokumenty - R9 MM-OTA

Przedview Odbiornik FrSky R9 MM-OTA: instrukcja obsługi i przewodnik
Kompleksowa instrukcja obsługi odbiornika FrSky R9 MM-OTA 900 MHz ACCESS. Obejmuje funkcje, specyfikacje, powiązania, aktualizacje oprogramowania układowego OTA, tryby awaryjne oraz zgodność z FCC dla entuzjastów RC.
Przedview Odbiornik FrSky TD R6: instrukcja obsługi i specyfikacja
Kompleksowa instrukcja obsługi dwupasmowego odbiornika RC FrSky TD R6 Tandem, obejmująca wprowadzenie,view, specyfikacje, funkcje, rejestracja, wiązanie, stany diod LED, przełączanie trybów, aktualizacje OTA, bezpieczeństwo w razie awarii i zgodność z FCC. Niezbędny przewodnik dla hobbystów RC korzystających ze sprzętu FrSky.
Przedview Instrukcja obsługi odbiornika FrSky ARCHER M+ – protokół ACCESS, aktualizacje OTA
Kompleksowa instrukcja obsługi odbiornika FrSky ARCHER M+. Dowiedz się więcej o jego funkcjach, specyfikacji, protokole ACCESS, aktualizacjach oprogramowania układowego OTA (Over-The-Air), procedurach łączenia oraz zgodności z FCC.
Przedview Odbiornik FrSky TD R6: instrukcja obsługi, funkcje i specyfikacje
Kompleksowy przewodnik po dwupasmowym odbiorniku RC FrSky TD R6, obejmujący jego funkcje, specyfikację, rejestrację, wiązanie, bezpieczeństwo w razie awarii i zgodność z normami FCC. Dowiedz się więcej o jego działaniu w pasmach 2.4 GHz i 900 MHz, możliwościach dalekiego zasięgu i telemetrii.
Przedview Instrukcja obsługi odbiornika FrSky ARCHER RS – funkcje, konfiguracja i specyfikacje
W niniejszej instrukcji znajdują się szczegółowe instrukcje dotyczące odbiornika FrSky ARCHER RS ACCESS, obejmujące jego funkcje, specyfikacje, rejestrację, łączenie, aktualizacje oprogramowania sprzętowego OTA, procedury sprawdzania zasięgu, ustawienia bezpieczeństwa oraz informacje dotyczące zgodności z przepisami FCC.
Przedview Odbiornik FrSky ARCHER GR8 ACCESS: instrukcja obsługi i funkcje
Comprehensive instruction manual for the FrSky ARCHER GR8 receiver, detailing its ACCESS protocol, OTA firmware updates, advanced variometer, receiver redundancy, and binding procedures. Learn about specifications, features, and setup for optimal performance.