PerfectPrime TC0520

PerfectPrime TC0520 4-Channels Thermocouple Thermometer User Manual

Model: TC0520 | Brand: PerfectPrime

1. Koniec produktuview

The PerfectPrime TC0520 is a versatile 4-channel thermocouple thermometer and data logger designed for precise temperature measurements across various applications. It supports K, J, E, and T type thermocouples, offering broad compatibility. With its large 3.35" LCD display, users can easily monitor real-time temperature readings from all four channels simultaneously. The device features an internal data log storage capacity of 16,000 records per channel, making it ideal for long-term monitoring.

Equipped with a USB PC interface, the TC0520 allows for real-time monitoring, graphic display of data, data logging, storage, and convenient data import/export. Its fast response time and adjustable sampling rate ensure accurate and timely data acquisition. Additional features include an adjustable auto power-off timer, a temperature alarm function, and an instant recall function for previously recorded data.

PerfectPrime TC0520 4-Channels Thermocouple Thermometer

Figure 1.1: PerfectPrime TC0520 4-Channels Thermocouple Thermometer, angled view pokazujący wyświetlacz i przyciski sterujące.

2. Rozpoczęcie pracy: konfiguracja

2.1 Zasilanie urządzenia

The TC0520 requires 2 baterie AAA for operation. Ensure batteries are inserted correctly according to polarity markings inside the battery compartment. For extended data logging without battery reliance, the device can be powered via a USB computer port or a USB power supply.

PerfectPrime TC0520 connected to a power bank via USB

Figure 2.1: The TC0520 connected to a USB power source, illustrating its capability for long-term data logging without needing AC power.

2.2 Podłączanie termopar

The device features four dedicated input ports for K, J, E, or T type thermocouples, labeled T1, T2, T3, and T4. Connect your desired thermocouples firmly into the corresponding ports at the top of the device. Ensure proper polarity (+/-) when connecting.

Spód view of PerfectPrime TC0520 showing thermocouple input ports

Rysunek 2.2: Dół view of the TC0520, highlighting the four thermocouple input ports (T1-T4) and their polarity markings.

2.3 Software Installation (Windows PC)

To utilize the data logging and analysis features, install the provided PC software on your Windows computer. The software enables real-time monitoring, graphical data representation, and data management (import/export).

  1. Insert the software CD (if included) or download the latest software from the PerfectPrime official webstrona.
  2. Aby dokończyć instalację, postępuj zgodnie z instrukcjami wyświetlanymi na ekranie.
  3. Connect the TC0520 to your PC using the supplied USB cable.
  4. Launch the software to establish communication with the device.

3. Instrukcja obsługi

3.1 Układ urządzenia i sterowanie

Przód view of PerfectPrime TC0520 showing LCD and buttons

Rycina 3.1: Przód view of the TC0520, detailing the LCD display and the arrangement of control buttons.

The TC0520 features a clear LCD display and an intuitive button layout for easy operation:

  • Wyświetlacz LCD: Shows real-time temperature readings for all four channels, battery status, and various indicators.
  • Power Button (Green): Włącza/wyłącza urządzenie.
  • SETUP Button (Blue): Accesses the setup menu for configuring settings like thermocouple type, sampling rate, and alarm thresholds.
  • Przycisk REC: Initiates or stops data logging.
  • Przytrzymaj przycisk: Zamraża bieżące odczyty na wyświetlaczu.
  • MIN/MAX/AVG Button: Toggles between minimum, maximum, and average recorded temperatures.
  • Przycisk PRZYWOŁANIA: Recalls stored data from the internal memory.
  • Przycisk PAMIĘĆ: Saves current readings to memory.
  • Przycisk °C/°F: Przełącza między jednostkami temperatury Celsjusza i Fahrenheita.
  • Backlight Button (Yellow): Activates the display backlight for improved visibility in low-light conditions.

3.2 Real-Time Temperature Measurement

Once powered on and thermocouples are connected, the device will immediately display the temperature readings for each active channel on the LCD. Ensure the correct thermocouple type (K, J, E, T) is selected in the setup menu for accurate readings.

3.3 Rejestracja danych

To begin data logging, press the REK button. The device will start recording temperature data at the pre-configured sampling interval. The internal memory can store up to 16,000 records per channel. Press REK again to stop logging.

3.4 Using PC Software

Connect the TC0520 to your PC via USB. Launch the PerfectPrime software. The software allows you to:

  • View real-time temperature data graphically.
  • Configure device settings remotely.
  • Download logged data from the device to your computer.
  • Export data in various formats (e.g., CSV) for further analysis in spreadsheet programs.

4. Konserwacja

4.1 Czyszczenie

To maintain the device's performance and appearance, wipe the exterior with a soft, damp ściereczką. Nie używaj środków czyszczących o działaniu ściernym ani rozpuszczalników, ponieważ mogą one uszkodzićasing lub wyświetlacz.

4.2 Wymiana baterii

When the low battery indicator appears on the display, replace the 2 AAA batteries promptly to ensure continuous operation and data integrity. Open the battery compartment cover on the back of the device, remove the old batteries, and insert new ones, observing correct polarity.

4.3 Przechowywanie

When not in use for extended periods, store the TC0520 in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if storing for a very long time to prevent leakage.

5. Rozwiązywanie Problemów

  • Urządzenie się nie włącza:

    Ensure batteries are inserted correctly with the correct polarity. Check if the batteries are fresh and have sufficient charge. If using USB power, ensure the USB cable is properly connected and the power source is active.

  • Niedokładne odczyty temperatury:

    Verify that the correct thermocouple type (K, J, E, or T) is selected in the device's setup menu matching the connected probes. Ensure thermocouples are properly connected to their respective ports and are not damaged. Allow sufficient time for the thermocouple to stabilize at the measurement point.

  • Cannot connect to PC software:

    Ensure the USB cable is securely connected to both the device and the PC. Verify that the PC software is installed correctly and is the latest version. Check your PC's device manager to ensure the USB driver for the TC0520 is recognized. Try restarting both the device and the PC.

  • Data logging not working:

    Check if the internal memory is full. If so, download and clear the data using the PC software. Ensure the device is not in HOLD mode. Verify that the sampling interval is set appropriately in the setup menu.

6. Specyfikacje

FunkcjaSzczegół
Numer modeluTC0520
Thermocouple Types SupportedK, J, E, T Type
Kanały4 kanały
Wyświetlacz3.35-calowy wyświetlacz LCD
Internal Data Log Storage16,000 records per channel
Interfejs PCUSB
Źródło zasilania2 AAA batteries / USB Powered
Wymiary produktuWymiary 7.5 x 3 x 18 cm
Waga przedmiotu0.33 gramów
Cechy specjalneAlarm function, Auto power-off, Instant recall
Zawarte komponentyBattery (for initial use, though listed as "No" for "Batteries Included?" in specs, it's often a starter set)
ProducentIdealnyPrime

7. Gwarancja i wsparcie

7.1 Informacje o gwarancji

Szczegóły dotyczące gwarancji są zazwyczaj podane w opakowaniu produktu lub na oficjalnej stronie producenta. website. Please refer to the documentation included with your PerfectPrime TC0520 for comprehensive warranty terms and conditions.

7.2 Obsługa klienta

For technical assistance, troubleshooting, or any inquiries regarding your PerfectPrime TC0520, please contact PerfectPrime customer support. Contact information can usually be found on the manufacturer's webmiejscu lub w opakowaniu produktu.

8. Oficjalne filmy o produktach

No official product videos with "Seller" as creator type were found in the provided data to embed directly. Please refer to the manufacturer's official webstrona internetowa lub strona produktu zawierająca wszelkie dostępne materiały wideo.

Powiązane dokumenty - TC0520

Przedview Przewodnik po protokole interfejsu USB PerfectPrime TC0520
Kompleksowy przewodnik po protokole interfejsu USB dla termometru-rejestratora danych PerfectPrime TC0520, zawierający szczegółowe informacje na temat poleceń, wyjścia danych i sprawdzania błędów.
Przedview PerfectPrime TC0580 Thermocouple Temperature Data Logger Instruction Manual
This instruction manual provides comprehensive guidance on the PerfectPrime TC0580 Thermocouple Temperature Data Logger. It covers product features, specifications, software installation, device operation, data logging, viewing, exporting, and troubleshooting.
Przedview Instrukcja obsługi manometru cyfrowego PerfectPrime AR168
Instrukcja obsługi cyfrowego manometru PerfectPrime AR168 obejmuje wprowadzenie do produktu, podstawowe funkcje, parametry techniczne, zakresy pomiarów, definicje symboli, działanie przycisków, środki ostrożności i dodatkowe informacje.