FLOMEC G2B15N09GMB

Instrukcja obsługi przepływomierza turbinowego FLOMEC G2B15N09GMB G2 z mosiądzu

Model: G2B15N09GMB

1. Wprowadzenie

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the FLOMEC G2B15N09GMB G2 Brass Turbine Flowmeter. Please read this manual thoroughly before using the device to ensure proper function and longevity.

2. Informacje dotyczące bezpieczeństwa

The FLOMEC G2B15N09GMB flowmeter is designed for industrial applications and features robust construction. Observe all local and national safety regulations during installation and operation. This device is certified as Intrinsically Safe and approved for hazardous locations, as indicated by CE and FM markings. Always ensure proper grounding and follow guidelines for electrical connections in potentially hazardous environments. Refer to the warning labels on the device for specific safety instructions.

Strona view of FLOMEC G2B15N09GMB flowmeter showing CE and FM certifications

Rysunek 2.1: Strona view of the FLOMEC G2B15N09GMB flowmeter, highlighting the CE and FM certifications for intrinsically safe operation and use in hazardous locations. Various warning labels are visible on the black electronic housing.

3. Koniec produktuview

The FLOMEC G2B15N09GMB is a G2 Series brass turbine flowmeter designed for accurate measurement of fluid flow. It features a 1.5-inch FNPT inlet/outlet and provides an accuracy of +/-0.75 percent of reading for flow rates ranging from 10 to 100 GPM (38 to 380 LPM). The brass housing ensures compatibility with a wide range of water-based applications, including glucose, juice, and lacquer thinner.

Główne cechy obejmują:

  • Wysoka dokładność: Provides precise flow measurement with +/-0.75% accuracy.
  • Wszechstronne zastosowanie: Compatible with various water applications due to its brass housing and wetted materials.
  • Wyświetlacz cyfrowy: Equipped with a 6-digit LCD display showing resettable batch total, non-resettable cumulative total, and rate of flow.
  • Konstrukcja modułowa: Allows for integration with output modules, sensors, and remote transmitters.
  • Łatwa konserwacja: Simplified internal parts and field-replaceable batteries contribute to ease of service.
Przód view of FLOMEC G2B15N09GMB flowmeter with digital display

Rycina 3.1: Przód view of the FLOMEC G2B15N09GMB flowmeter, showing the digital LCD display with 'CALIBRATE' and 'DISPLAY' buttons. The flow direction arrow is visible on the brass body.

4. Konfiguracja i instalacja

The FLOMEC G2B15N09GMB flowmeter features a compact design for straightforward installation. Ensure the flowmeter is installed in the correct orientation, aligning the flow direction arrow on the meter body with the direction of fluid flow in the pipe. The meter utilizes 1.5-inch FNPT (Female National Pipe Taper) connections for integration into your piping system.

  1. Prepare the Piping: Ensure the piping system is clean and free of debris before installation.
  2. Nałóż uszczelniacz: Use an appropriate thread sealant on the 1.5-inch FNPT connections to prevent leaks.
  3. Install Meter: Thread the flowmeter into the pipeline, ensuring the flow arrow on the meter body points in the direction of fluid flow. Tighten connections securely but do not overtighten.
  4. Sprawdź, czy nie ma wycieków: After installation, slowly introduce fluid into the system and check all connections for leaks.
  5. Modular Integration: If using optional output modules, sensors, or remote transmitters, refer to their respective manuals for connection instructions.

5. Działanie

The FLOMEC G2B15N09GMB flowmeter is equipped with a 6-digit LCD display that provides real-time flow data. The display shows a resettable batch total, a non-resettable cumulative total, and the current rate of flow. The meter is factory calibrated in gallons but allows for field calibration if required.

  • Włączanie: The display is powered by two field-replaceable lithium batteries. It will automatically activate when flow is detected or when a button is pressed.
  • Tryby wyświetlania: Use the 'DISPLAY' button to cycle through the different display modes: Rate of Flow, Resettable Batch Total, and Non-Resettable Cumulative Total.
  • Resetting Batch Total: To reset the batch total, navigate to the batch total display mode and press and hold the 'CALIBRATE' button until the total resets.
  • Kalibrowanie: For field calibration, refer to the detailed calibration procedure in the full product manual. The 'CALIBRATE' button is used in conjunction with specific flow rates to adjust accuracy.

6. Konserwacja

Regular maintenance ensures the continued accuracy and reliability of your FLOMEC G2B15N09GMB flowmeter.

  • Wymiana baterii: The meter is powered by two lithium batteries with an approximate 5-year life. When the battery indicator appears, replace the batteries promptly. Non-volatile totals protect meter data during battery replacement.
  • Czyszczenie: Periodically inspect the meter for external debris. Clean the display and housing with a damp ściereczka. Nie należy używać środków czyszczących o właściwościach ściernych ani rozpuszczalników.
  • Części wewnętrzne: The internal parts are designed for simple replacement, facilitating ease of maintenance. If internal components require service, contact FLOMEC support or a qualified technician.
  • Materiały zwilżane: The wetted materials include 316 Stainless Steel, brass, Ceramic, PVDF, and Tungsten Carbide, chosen for compatibility with various fluids. Ensure the fluid being measured is compatible with these materials to prevent corrosion or damage.

7. Rozwiązywanie Problemów

If you encounter issues with your FLOMEC G2B15N09GMB flowmeter, consider the following basic troubleshooting steps:

  • Brak wyświetlacza/niski poziom naładowania baterii: Check the battery indicator. If low, replace the batteries. Ensure proper battery orientation.
  • Niedokładne odczyty: Verify the flow direction is correct. Check for air bubbles or debris in the fluid stream. Consider performing a field calibration if necessary.
  • No Flow Reading: Ensure there is actual fluid flow through the meter. Check for blockages in the pipeline. Verify the turbine is rotating freely (if accessible and safe to inspect).
  • Wycieki: Re-check all threaded connections for proper sealant and tightness.

For persistent issues or complex problems, contact FLOMEC technical support.

8. Specyfikacje

ParametrSpecyfikacja
Numer modeluG2B15N09GMB
Zakres natężenia przepływu10-100 gal / min (38-380 l / min)
Dokładność+/-0.75% odczytu
Rozmiar połączenia1.5-calowy FNPT
Materiał obudowyMosiądz
Materiały zwilżane316 Stainless Steel, Brass, Ceramic, PVDF, Tungsten Carbide
Wyświetlacz6-digit LCD (Batch, Cumulative, Rate of Flow)
Źródło zasilania2x Lithium Batteries (5-year life)
CertyfikatyIntrinsically Safe, CE, FM Approved
Przybliżone wymiary opakowania9.3 x 5.5 x 4.6 cala
Przybliżona waga paczki2.2 funtów

9. Gwarancja i wsparcie

For warranty information, technical support, or service inquiries, please contact FLOMEC or Great Plains Industries directly. Retain your purchase receipt for warranty claims. Contact details can typically be found on the manufacturer's webwitryny lub opakowania produktu.

Powiązane dokumenty - G2B15N09GMB

Przedview Instrukcja obsługi elektronicznych przepływomierzy wody serii FLOMEC TM
Instrukcja obsługi elektronicznych przepływomierzy wody FLOMEC serii TM (rozmiary od 1/2 cala do 2 cali). Obejmuje specyfikacje, instalację, obsługę, konserwację i gwarancję modeli od TM05XXXXXX do TM20XXXXXX.
Przedview Instrukcja obsługi elektronicznych przepływomierzy do wody serii FLOMEC TM
Kompleksowa instrukcja obsługi elektronicznych przepływomierzy wody serii FLOMEC TM (modele 3- i 4-calowe TM30XXXXXX, TM40XXXXXX). Obejmuje instalację, obsługę, konserwację, specyfikacje i rozwiązywanie problemów, zapewniając niezawodny pomiar przepływu wody.
Przedview Instrukcja obsługi modułu FLOMEC 4-20mA
Kompleksowa instrukcja obsługi modułu FLOMEC 4-20 mA zawierająca szczegółowe informacje na temat specyfikacji, instalacji, okablowania, obsługi, kalibracji i rozwiązywania problemów w przypadku stosowania z licznikami turbinowymi FLOMEC.
Przedview Instrukcja obsługi przepływomierza ultradźwiękowego do nawadniania liniowego FLOMEC QS100-10
W niniejszej instrukcji zawarto instrukcje dotyczące przepływomierza ultradźwiękowego do nawadniania liniowego FLOMEC QS100-10, obejmujące wymagania dotyczące użytkowania, bezpieczeństwo, specyfikacje, instalację, obsługę, rozwiązywanie problemów i informacje gwarancyjne.
Przedview Instrukcja obsługi i instalacji zestawu FLOMEC Remote Kit (Gen 2)
Kompleksowy przewodnik dotyczący instalacji, obsługi i konserwacji zestawu FLOMEC Remote Kit (Gen 2), zawierający specyfikacje, listę części i informacje gwarancyjne. Zatwierdzony przez FM do stosowania w strefach niebezpiecznych.
Przedview Instrukcja instalacji czujnika przepływu ultradźwiękowego FLOMEC QS100
Szczegółowa instrukcja instalacji ultradźwiękowego czujnika przepływu FLOMEC QS100, obejmująca wymagania dotyczące komponentów, okablowania i prawidłowego rozmieszczenia w systemach nawadniających. Zawiera schematy i uwagi techniczne.