1. Wprowadzenie
The Fieldpiece SM480V SMAN Digital Manifold is an advanced tool designed for HVAC and refrigeration professionals. It accurately measures low and high pressures, superheat, and subcooling, and includes a micron gauge for precise vacuum measurements. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your SM480V unit.
2. Główne cechy
- Advanced Digital Manifold & Micron Gauge: For comprehensive HVAC & Refrigeration diagnostics and service.
- Dokładne pomiary: Precisely measures low and high pressure, superheat, and subcooling.
- Protected Thermocouple Jacks: Dedicated jacks for pipe and outdoor temperature sensors.
- Four-Valve Manifold: Includes an integrated vacuum gauge for efficient system evacuation.
- Job Link Psychrometer Probe Connectivity: Allows connection of Job Link Psychrometer probes to the SMAN for enhanced diagnostics.
- Rejestrowanie danych: Equipped with internal data logging capabilities for up to 7 continuous days or 9 jobs.
- Temperature Compensated System Tightness Test: Provides reliable leak detection.

3. Co znajduje się w pudełku
Your Fieldpiece SM480V package includes the following items:
- SM480V SMAN 4-port Refrigerant Manifold
- (2) TC24 Wired Type-K Pipe Clamp Termopary
- (1) ATA1 Type-K Bead Thermocouple with Clip
- (1) ANC11 Padded Drawstring Case
- Batteries (6 AA batteries required, included)

4. Konfiguracja
4.1. Instalacja baterii
- Locate the battery compartment on the back of the manifold.
- Otwórz pokrywę komory.
- Insert 6 AA alkaline batteries, ensuring correct polarity.
- Dokładnie zamknij pokrywę komory baterii.
4.2. Connecting Thermocouples
- Connect the TC24 Wired Type-K Pipe Clamp Thermocouples to the protected thermocouple jacks on the manifold.
- Connect the ATA1 Type-K Bead Thermocouple to its designated jack if needed for ambient or specific component temperature readings.
4.3. Hose Connections
The SM480V features a four-valve manifold. Connect your refrigerant hoses to the appropriate ports:
- Low Side: Typically blue hose.
- High Side: Typically red hose.
- Vacuum Port (VAC): For connecting to a vacuum pump.
- Refrigerant Port (REF): For connecting to a refrigerant tank.

5. Instrukcja obsługi
5.1. Włączanie/wyłączanie zasilania
Press and hold the power button to turn the unit on or off. A short press will toggle the backlight.
5.2. Selecting Refrigerant
Use the 'MENU' button to navigate to the refrigerant selection. Use the arrow buttons to scroll through the available refrigerants (e.g., R22, R410A, R134a, R404A, R407C, R448A, R449A, R452A, R32, R454B, R454C, R407A, R407F, R422B, R422C, R422D, R507A, R513A, R1234yf, R1234ze, R600a, R290, R744). Press 'ENTER' to confirm your selection. The SM480V supports downloading new refrigerants via the Job Link app.
5.3. Wykonywanie pomiarów
Once connected to the system and refrigerant is selected, the manifold will display real-time pressure and temperature readings. Superheat and subcooling values will be calculated automatically based on the connected thermocouples.

5.4. Rejestrowanie danych
The SM480V can log data internally. To initiate data logging:
- Navigate to the data logging menu.
- Set the desired logging duration and interval.
- Start the logging process. The manifold will store measurements, which can be downloaded later via the Micro USB port.
5.5. System Tightness Test
Utilize the temperature compensated system tightness test feature to accurately detect leaks in the system. Follow the on-screen prompts to perform the test.
5.6. Wireless Connectivity (Job Link App)
Connect your SM480V to the Fieldpiece Job Link app on your smartphone or tablet for remote monitoring, advanced diagnostics, and report generation. This allows you to view readings from a distance and manage job data efficiently.
6. Konserwacja
6.1. Czyszczenie
Wipe the manifold with a damp Ściereczką. Nie używaj środków czyszczących o właściwościach ściernych ani rozpuszczalników. Przed przechowywaniem upewnij się, że urządzenie jest suche.
6.2. Wymiana baterii
Wymień baterie, gdy na wyświetlaczu pojawi się wskaźnik niskiego poziomu naładowania baterii. Zapewni to ciągłą pracę urządzenia i dokładne odczyty.
6.3. Kalibracja czujnika
Regularly check and calibrate sensors as per manufacturer recommendations to maintain accuracy. Refer to the Job Link app or Fieldpiece website for detailed calibration procedures.
6.4. Aktualizacje oprogramowania sprzętowego
Periodically check for firmware updates via the Fieldpiece website or Job Link app. Updates can provide new features, refrigerant profiles, and performance improvements. Use the Micro USB port to update firmware.
7. Rozwiązywanie Problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Brak wyświetlacza/Urządzenie nie włącza się | Rozładowane baterie; Nieprawidłowa instalacja baterii | Wymień baterie; Sprawdź biegunowość baterii |
| Niedokładne odczyty ciśnienia/temperatury | Sensors not properly connected; Sensors need calibration; Incorrect refrigerant selected | Ensure secure connections; Calibrate sensors; Verify correct refrigerant selection |
| Problemy z łącznością bezprzewodową | Out of range; Bluetooth interference; App not updated | Move closer to the manifold; Minimize interference; Update Job Link app |
| Vacuum readings unstable | System leak; Moisture in system; Contaminated manifold/hoses | Perform tightness test; Ensure thorough evacuation; Clean manifold and hoses |
8. Specyfikacje
- Wyświetlacz: LCD (przekątna 5 cali)
- Maksymalne ciśnienie kolektora: 800 psig (5500 kPa)
- Typ baterii: 6 x AA alkaliczne
- Czas pracy baterii: Typowo 350 godzin (bez odkurzacza, podświetlenia i łączności bezprzewodowej)
- Częstotliwość radiowa: 2.4 GHz
- Zasięg bezprzewodowy: 1000 feet (305 meters) line of sight (distance decreases through obstructions)
- Port danych: Micro USB (for extracting data logs or updating firmware)
- Środowisko operacyjne: 32°F do 122°F (0°C do 50°C) przy <75% RH
- Wodoodporność: Zaprojektowany do IP54
- Tworzywo: Tworzywo ABS
- Waga przedmiotu: 6.2 funtów
- Wymiary produktu: 63 x 10.5 x 12.5 cala


9. Gwarancja i wsparcie
For warranty information, product registration, and technical support, please visit the official Fieldpiece webOdwiedź witrynę lub skontaktuj się z działem obsługi klienta. Zachowaj paragon jako dowód zakupu na wypadek reklamacji.
Notatka: Warranty terms may vary based on region and retailer. It is recommended to purchase from authorized dealers to ensure full warranty coverage.