Apera Instruments AI1107

Apera Instruments 3M KCL Storage Soaking Solution

Model: AI1107

Marka: Apera Instruments

Produkt ponadview

The Apera Instruments 3M KCL Storage Solution is specifically formulated with high-purity chemicals to maintain and extend the operational lifespan of pH and ORP electrodes. This solution is essential for proper electrode care, preventing sensitivity and accuracy degradation that can occur when electrodes are stored dry.

Główne cechy obejmują:

Konfiguracja i przygotowanie

Before storing your pH or ORP electrode, ensure it is thoroughly cleaned according to your electrode's specific cleaning instructions. This removes any contaminants that could affect the electrode's performance or the storage solution's integrity.

Apera Instruments 3M KCL Storage Solution bottle

Obraz: A white plastic bottle containing Apera Instruments 3M KCL Storage Solution. The label on the bottle is primarily in German, indicating "Elektrolyt Lösung" (Electrolyte Solution) and "Kaliumchlorid 3mol/l" (Potassium Chloride 3mol/l), with a volume of "250 ml". The Apera Instruments logo is visible at the top of the label. The bottle has a black ribbed screw cap.

Instrukcja obsługi

Routine Electrode Storage

To maintain optimal performance and extend the life of your pH or ORP electrode, it is highly recommended to store the electrode in Apera Instruments 3M KCL Storage Solution when not in use. This prevents the electrode's sensitive glass bulb and reference junction from drying out.

  1. Ensure the electrode is clean.
  2. Zdejmij nasadkę ochronną z elektrody.
  3. Fill the electrode's storage cap or a small container with a sufficient amount of 3M KCL storage solution to fully immerse the electrode's sensing bulb and reference junction.
  4. Place the electrode into the solution, ensuring the sensing part is completely submerged.
  5. Secure the electrode in the solution to prevent spillage and evaporation.

Restoring Dry or Sluggish Electrodes

If your pH or ORP electrode has been stored dry, or if it exhibits sluggish response or unstable readings, its sensitivity and accuracy may be temporarily compromised. The 3M KCL storage solution can help restore its performance.

  1. Dokładnie wyczyść elektrodę.
  2. Immerse the electrode's sensing bulb and reference junction in Apera Instruments 3M KCL Storage Solution.
  3. Allow the electrode to soak in the solution for a minimum of 1 hour, or preferably overnight, to rehydrate the glass membrane and re-establish the reference junction potential.
  4. After soaking, rinse the electrode with distilled water and perform a calibration before use.

Maintenance and Storage of Solution

To ensure the longevity and effectiveness of your Apera Instruments 3M KCL Storage Solution, follow these guidelines:

Rozwiązywanie problemów

This section addresses common issues related to electrode performance and how the storage solution can help.

ProblemMożliwa przyczynaRozwiązanie
Electrode shows unstable readings or slow response.Electrode membrane is dry or dehydrated.Soak the electrode in Apera Instruments 3M KCL Storage Solution for at least 1 hour, or overnight. Ensure the sensing bulb is fully submerged.
Electrode requires frequent calibration.Improper storage leading to degradation of electrode performance.Always store the electrode in 3M KCL storage solution when not in use. If performance has degraded, try reconditioning by soaking.
Solution appears cloudy or contaminated.Exposure to contaminants or expired solution.Discard the contaminated or expired solution and replace with fresh Apera Instruments 3M KCL Storage Solution.

Specyfikacje

AtrybutSzczegół
Nazwa produktu3M KCL Storage Soaking Solution
Numer modeluAI1107
MarkaInstrumenty Apery
Objętość przedmiotu8 uncji płynu (ok. 236 ml)
KCL Concentration3M (3 mol/L)
Formularz przedmiotuPłyn
Informacje o pakiecieButelka
Wymiary produktu6.3 x 1.97 x 2.36 cala
Waga przedmiotu9 uncji
Kraj pochodzeniaUSA

Informacje o gwarancji

Specific warranty details for the Apera Instruments 3M KCL Storage Soaking Solution are not provided in this manual. For comprehensive warranty information, please refer to the official Apera Instruments webodwiedź witrynę lub skontaktuj się bezpośrednio z działem obsługi klienta.

Wsparcie i kontakt

For further assistance, technical support, or to download batch certificates for your solution, please visit the official Apera Instruments webstrona:

www.aperrainst.com

(Note: The image indicates a German website for certificates: aperainst.de/chargenzertifikate/. Please refer to your region's specific support channels.)

Powiązane dokumenty - AI1107

Przedview Apera SX811-SS przenośny miernik pH do badania żywności: instrukcja obsługi i specyfikacja
Kompleksowa instrukcja obsługi i specyfikacja techniczna przenośnego pH-metru Apera SX811-SS, przeznaczonego do precyzyjnego testowania żywności. Dowiedz się więcej o funkcjach, kalibracji, konfiguracji, komunikacji USB i rozwiązywaniu problemów.
Przedview Instrukcja obsługi inteligentnego miernika pH PH60Z-HT — Apera Instruments
Instrukcja obsługi inteligentnego miernika pH Apera Instruments PH60Z-HT zawierająca szczegółowe informacje na temat jego funkcji, obsługi, kalibracji, konserwacji i rozwiązywania problemów w przypadku roztworów o wysokiej temperaturze i roztworów żrących.
Przedview PH60Z-PW Inteligentny pH-metr Bedienungsanleitung für reines Wasser
Umfassende Bedienungsanleitung für das Apera Instruments PH60Z-PW Inteligentny miernik pH. Erfahren Sie mehr über Kalibrierung, Messung, Wartung und technische Daten für präzise pH-Messungen in Reinem Wasser.
Przedview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instructions for operating, calibrating, and maintaining the Apera PH700 Benchtop pH Meter. It covers technical specifications, instrument description, measurement procedures for pH and ORP, parameter settings, electrode care, and troubleshooting.
Przedview Apera Instruments SX731 Portable pH/Conductivity/ORP Meter User Manual
User manual for the Apera Instruments SX731 Portable pH/Conductivity/ORP Meter, covering its features, technical specifications, operation, calibration, maintenance, and warranty.
Przedview Karta charakterystyki roztworu buforowego pH 4.00 firmy APERA Instruments
Karta charakterystyki substancji niebezpiecznej (SDS) roztworu buforowego pH 4.00 firmy APERA Instruments zawierająca podstawowe informacje na temat identyfikacji, zagrożeń, pierwszej pomocy, obchodzenia się z produktem, przechowywania i zgodności z przepisami.