The Apera Instruments PH820 Benchtop pH Meter Kit is designed for reliable and accurate pH measurements in laboratory settings. It features advanced functionalities including intelligent calibration, data management, and a durable, water-resistant structure. This manual provides detailed instructions for proper use and care of your PH820 meter.

Apera Instruments PH820 Benchtop pH Meter Kit with electrode and stand

Figure 1: Apera Instruments PH820 Benchtop pH Meter Kit, showing the main unit, electrode, temperature probe, and electrode arm.

Key features of the PH820 include:

Organizować coś

Rozpakowywanie i sprawdzanie podzespołów

Carefully unpack all components from the kit. Verify that the following items are present:

Łączenie komponentów

Connect the electrode, temperature probe, and power adapter to the corresponding ports on the back of the PH820 meter unit. Ensure all connections are secure.

Back panel of Apera Instruments PH820 pH meter showing connection ports

Rysunek 2: Tył view of the PH820 meter, highlighting the REF, pH/mV, TEMP, RS232, and DC 9V input ports.

  1. Podłączenie elektrod: Plug the LabSen 211 pH Electrode into the port labeled "pH/mV".
  2. Podłączenie sondy temperatury: Insert the temperature probe into the port labeled "TEMP".
  3. Podłączenie zasilania: Connect the power adapter to the "DC 9V" port and then to a power outlet.
  4. Electrode Arm Assembly: Attach the flexible electrode arm and holder to the side of the meter unit for convenient electrode placement during measurements.

Instrukcja obsługi

Basic pH Measurement

  1. Włącz miernik naciskając przycisk zasilania.
  2. Opłukać elektrodę wodą destylowaną i delikatnie osuszyć.
  3. Immerse the electrode and temperature probe into the samproztwór. Upewnij się, że końcówka elektrody jest całkowicie zanurzona.
  4. Wait for the reading on the large LCD to stabilize. The meter displays pH and temperature simultaneously.
  5. Record the stable reading.

Kalibracja pH

The PH820 supports 1 to 5 points automatic calibration. Regular calibration ensures measurement accuracy.

  1. Prepare the standard calibration solutions (4.00 pH, 7.00 pH, 10.01 pH are included).
  2. Naciśnij CAL przycisk, aby wejść w tryb kalibracji.
  3. Rinse the electrode and immerse it into the first calibration solution (e.g., 7.00 pH).
  4. The meter will automatically recognize the solution and begin calibration. Wait for the stability icon to appear.
  5. Once stable, the meter will prompt for the next calibration point. Repeat the rinsing and immersion process for subsequent solutions.
  6. The self-diagnosis function will provide feedback on the calibration process and electrode condition, including slope data.
  7. Exit calibration mode once all desired points are completed.

Zarządzanie danymi

The PH820 allows for GLP data management, storing up to 500 groups of data. Data can be output via USB to a PC using the provided PC-Link software (Windows-based system only). Auto-timing data logging can also be configured.

ORP Measurement (Optional)

The PH820 can measure Oxidation-Reduction Potential (ORP) when an ORP electrode (e.g., 301Pt-C, sold separately) is connected to the pH/mV port. Refer to the ORP electrode's specific instructions for calibration and measurement procedures.

Konserwacja

Pielęgnacja elektrod

Proper care of the LabSen 211 pH Electrode is crucial for maintaining accuracy and extending its lifespan.

Close-up of the LabSen 211 pH electrode

Rysunek 3: Zbliżenie view of the LabSen 211 pH Electrode, showing its glass body and sensor tip.

Pielęgnacja licznika

The PH820 meter unit is IP54 water-resistant, meaning it is protected from dust and splashing water. However, it should not be submerged. Keep the meter clean and dry. Use a soft, damp cloth to wipe the surface. Avoid using abrasive cleaners or solvents.

Rozwiązywanie problemów

The PH820 features a self-diagnosis function that can assist in identifying and fixing common problems, particularly during calibration. Refer to the meter's display for diagnostic messages.

ProblemMożliwa przyczynaRozwiązanie
Niestabilne odczytyZabrudzona elektroda; pęcherzyki powietrza; niewystarczająca ilośćample volume; expired calibration.Clean electrode; ensure no bubbles; use adequate sample; recalibrate.
Błąd kalibracjiIncorrect buffer solution; contaminated electrode; electrode aging.Use fresh, correct buffers; clean electrode; check electrode slope data (self-diagnosis) for replacement indication.
Brak wyświetlacza/zasilaniaPower adapter issue; loose connection.Check power adapter and outlet; ensure all cables are securely connected.
Niedokładne odczytyElectrode not calibrated; temperature not compensated; damaged electrode.Perform calibration; ensure temperature probe is functioning; inspect electrode for damage.

For persistent issues not resolved by the above, please contact Apera Instruments customer support.

Specyfikacje

ParametrWartość
Numer modeluAI531
Dokładność pH±0.002 pH±1 digit
Punkty kalibracji1 to 5 points (Auto.)
Przechowywanie danych500 groups (GLP compliant)
Wyjście danychUSB (PC software support)
Odporność na wodęIP54
Moc wejściowa120 V AC 60 Hz
Moc wyjściowa9V 300mA
Wymiary opakowania10.67 x 10.2 x 6.65 cala
Waga6.69 funtów
CertyfikatyCE, RoHS, ISO 9001:2015

Gwarancja i wsparcie

Apera Instruments products are manufactured under an ISO 9001:2015 certified quality system, ensuring high standards of production. For specific warranty information and technical support, please refer to the warranty card included with your product or visit the official Apera Instruments website. You may also contact their customer service directly for assistance with product operation, troubleshooting, or parts replacement.

Powiązane dokumenty - AI531

Przedview Instrukcja obsługi inteligentnego miernika pH Apera PH60Z-WW
Kompleksowa instrukcja obsługi inteligentnego miernika pH Apera PH60Z-WW, obejmująca informacje na temat konfiguracji, kalibracji, pomiarów, rozwiązywania problemów oraz specyfikacji ścieków, zawiesin i emulsji.
Przedview Instrukcja obsługi inteligentnego miernika pH PH60Z-HT — Apera Instruments
Instrukcja obsługi inteligentnego miernika pH Apera Instruments PH60Z-HT zawierająca szczegółowe informacje na temat jego funkcji, obsługi, kalibracji, konserwacji i rozwiązywania problemów w przypadku roztworów o wysokiej temperaturze i roztworów żrących.
Przedview Apera SX811-SS przenośny miernik pH do badania żywności: instrukcja obsługi i specyfikacja
Kompleksowa instrukcja obsługi i specyfikacja techniczna przenośnego pH-metru Apera SX811-SS, przeznaczonego do precyzyjnego testowania żywności. Dowiedz się więcej o funkcjach, kalibracji, konfiguracji, komunikacji USB i rozwiązywaniu problemów.
Przedview Inteligentny miernik pH Apera PH60Z-MS: Bedienungsanleitung für Kleinvolumenmessungen
Diese Bedienungsanleitung bietet szczegółowe informacje o Verwendung des Apera PH60Z-MS Inteligentne pH-metry, einschließlich Kalibrierung, Messung, Wartung und Fehlerbehebung für präzise pH-Messungen in kleinen Volumina.
Przedview Instrukcja obsługi miernika pH Apera PH60-HT: roztwory o wysokiej temperaturze i żrące
Comprehensive user manual for the Apera PH60-HT pH Meter, designed for accurate pH measurement in high temperature (up to 140°C) and caustic solutions. Covers kit contents, operation, calibration, electrode care, parameter settings, technical specifications, troubleshooting, and warranty.
Przedview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instruction manual for the Apera PH700 Benchtop pH Meter, covering features, specifications, operation, calibration, maintenance, and troubleshooting.