1. Wprowadzenie i koniecview
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Terma Split TS1 Heating Element. This product is designed to provide heating for compatible systems, typically radiators or towel warmers. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Instrukcje bezpieczeństwa
OSTRZEŻENIE: Nieprzestrzeganie tych instrukcji bezpieczeństwa może skutkować porażeniem prądem, pożarem, poważnymi obrażeniami, a nawet śmiercią.
- Installation and maintenance must be performed by a qualified electrician or authorized service personnel in accordance with all local and national electrical codes.
- Przed przystąpieniem do prac instalacyjnych, konserwacyjnych lub rozwiązywania problemów należy upewnić się, że zasilanie jest odłączone.
- Do not operate the heating element if it is damaged or if the power cord is frayed or broken.
- This heating element is designed for specific applications. Do not use it for purposes other than its intended use.
- The heating element will become hot during operation. Avoid direct contact to prevent burns.
- Keep children and pets away from the heating element during operation.
- Zapewnij prawidłowe uziemienie instalacji elektrycznej.
- Do not immerse the electrical connection part of the element in water or other liquids.
3. Składniki produktu i więcejview
The Terma Split TS1 Heating Element consists of a heating rod and an integrated electrical connection point. Below are images illustrating the product and its key features.

Rysunek 3.1: Close-up of the Terma Split TS1 heating element's electrical connection and threaded base. This image highlights the brass-colored threaded section for secure installation and the multi-pin electrical connector at the end.

Rysunek 3.2: Pełna długość view of the Terma Split TS1 heating element. This image shows the entire length of the metallic heating rod, designed to be inserted into a compatible radiator or towel warmer, with the electrical connection visible at the bottom.

Rysunek 3.3: Technical drawing of the Terma Split TS1 heating element, illustrating its dimensions (L ± 5 mm) and a table correlating length (L [mm]) with power (Power [W]). For this specific model, the length is 310 mm and the power is 300 W.
4. Konfiguracja i instalacja
The Terma Split TS1 Heating Element is designed for integration into compatible heating systems. Professional installation is highly recommended to ensure proper function and safety.
4.1 Kontrole przed instalacją
- Verify that the heating element's specifications (voltage, cotage) match your system's requirements. This model operates at 230 Volts and 300 Watts.
- Ensure the radiator or towel warmer is compatible with the heating element's dimensions (310 mm length).
- Confirm that the electrical circuit has appropriate overcurrent protection.
- Inspect the heating element for any visible damage before installation.
4.2 Procedura instalacji
- Odłącz zasilanie: Ensure the main power supply to the installation area is completely disconnected at the circuit breaker.
- Prepare Radiator/Towel Warmer: If installing into an existing system, drain the radiator or towel warmer completely.
- Insert Element: Carefully insert the heating element into the designated opening of the radiator or towel warmer. The threaded section should align with the opening.
- Bezpieczny element: Tighten the heating element securely into place. Use appropriate tools, but do not overtighten to avoid damaging the threads or seals.
- Podłączenie elektryczne: Connect the heating element to the electrical supply according to local wiring regulations. Ensure all connections are secure and properly insulated. This typically involves connecting live, neutral, and ground wires.
- Fill System (if applicable): If the system was drained, refill it with the appropriate heating fluid (e.g., water or glycol mixture) as per the radiator/towel warmer manufacturer's instructions. Bleed any air from the system.
- Test: Once installation is complete and all connections are verified, restore power and test the heating element's operation.
5. Instrukcja obsługi
The Terma Split TS1 Heating Element operates by converting electrical energy into heat. Once properly installed and connected to a power source, it will begin to heat the fluid within the radiator or towel warmer.
- Włączanie: Activate the power supply to the heating element via its dedicated switch or circuit breaker.
- Cykl grzewczy: The element will begin to heat. The time required to reach the desired temperature will depend on the volume of fluid and the ambient conditions.
- Wyłączone: To turn off the heating element, deactivate the power supply.
- Kontrola temperatury: If your system includes a thermostat or control unit, refer to its specific manual for temperature adjustment and programming. This heating element itself does not have integrated temperature controls.
6. Konserwacja
Regularna konserwacja zapewnia długowieczność i wydajną pracę elementu grzejnego.
- Odłączenie zasilania: Przed przystąpieniem do prac konserwacyjnych należy zawsze odłączyć zasilanie.
- Czyszczenie: Periodically clean the exterior of the heating element (if accessible) and the surrounding area to prevent dust and debris buildup. Use a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Kontrola wizualna: Regularly inspect the power cord and connections for any signs of wear, damage, or loose connections.
- System Fluid: Ensure the heating system fluid level is adequate and that the fluid quality is maintained according to the radiator/towel warmer manufacturer's recommendations.
- Kontrola profesjonalna: It is recommended to have a qualified technician inspect the heating system and element periodically, especially if you notice any changes in performance.
7. Rozwiązywanie Problemów
If you encounter issues with your Terma Split TS1 Heating Element, refer to the following common troubleshooting steps. For complex issues, contact a qualified technician.
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| Heating element does not heat. |
|
|
| System not heating sufficiently. |
|
|
| Unusual noises from the system. |
|
|
8. Specyfikacje
| Atrybut | Wartość |
|---|---|
| Marka | Termiczny |
| Numer modelu | WETS103KD |
| Producent | Armacell GmbH |
| Wymiary (dł. x szer. x wys.) | 0.22 x 0.22 x 3.4 cm (element length 310 mm) |
| Waga | 150 gramów |
| Tomtage | 230 wolty |
| Moc (Wattage) | 300 watów |
| Ilość przedmiotów | 1 |
| Wymagane baterie | NIE |
| ASIN | B07JRDP1N |
| Pierwsza dostępna data | 27 stycznia 2019 r. |
9. Gwarancja i wsparcie
Specific warranty information for the Terma Split TS1 Heating Element may vary by region and retailer. Please refer to your purchase documentation or contact your point of sale for detailed warranty terms and conditions.
For technical support or inquiries regarding this product, please contact Terma customer service or your authorized distributor. Ensure you have your product model number (WETS103KD) and purchase details available when contacting support.
Uwaga: Informacje dotyczące dostępności części zamiennych nie są zawarte w specyfikacji produktu.