1. Wprowadzenie

This manual provides detailed instructions for the safe and effective operation of the SIGLENT SVA1015X Spectrum Vector Analyzer. The SVA1015X is a versatile instrument designed for RF signal and network analysis, offering a frequency range from 9 kHz up to 1.5 GHz. It combines the functionalities of a spectrum analyzer and a vector network analyzer, making it suitable for various applications including broadcast monitoring, S-parameter measurement, cable and antenna testing, and EMI pre-compliance testing.

Please read this manual thoroughly before using the device to ensure proper handling and to maximize its performance and longevity.

2. Informacje dotyczące bezpieczeństwa

Aby zapobiec obrażeniom ciała i uszkodzeniu urządzenia, należy przestrzegać następujących środków ostrożności:

3. Koniec produktuview

The SIGLENT SVA1015X is a high-performance spectrum and vector network analyzer. Its design integrates advanced microwave technology and digital processing algorithms to deliver reliable and accurate measurements.

Główne cechy:

Panel przedni nadview:

SIGLENT SVA1015X Spectrum Vector Analyzer Front View

Rycina 3.1: Przód view of the SIGLENT SVA1015X Spectrum Vector Analyzer, showing the large display, control buttons, and input/output ports.

The front panel features a large 10.1-inch multi-touch display for intuitive operation. To the right of the display are dedicated function keys for control, setting, marker, and measurement operations. A rotary knob and numeric keypad provide additional input methods. The bottom section includes USB ports for external storage or peripherals, a TG Source port for the tracking generator, and RF Input ports (PORT 1 and PORT 2) for signal connections.

SIGLENT SVA1015X Displaying Distance-to-Fault Measurement

Figure 3.2: The SVA1015X display showing a Distance-to-Fault (DTF) measurement, illustrating the graphical interface and measurement parameters.

The user interface is designed for clarity and ease of use, supporting both touch input and traditional button/knob controls. It also supports external mouse and keyboard for enhanced usability.

4. Konfiguracja

4.1 Rozpakowanie i kontrola

  1. Ostrożnie wyjmij instrument z opakowania.
  2. Inspect the instrument for any signs of damage during transit. If damage is found, contact your supplier immediately.
  3. Sprawdź, czy wszystkie akcesoria wymienione w liście przewozowym są obecne.

4.2 Połączenie zasilania

4.3 Pierwsze włączenie zasilania

5. Instrukcja obsługi

5.1 Analiza widmowa

The SVA1015X functions as a full-featured spectrum analyzer, allowing you to measure the magnitude of an input signal versus frequency within the instrument's frequency range.

  1. Connect the signal to be analyzed to the RF INPUT PORT 1.
  2. Naciśnij Tryb button and select 'Spectrum Analyzer'.
  3. Dostosuj Częstotliwość settings (Center Frequency, Span) to define the measurement range.
  4. Konfiguruj Amplitość settings (Reference Level, Attenuation) to optimize the signal display.
  5. Ustaw BW (Resolution Bandwidth, Video Bandwidth) for desired measurement resolution and noise reduction.
  6. Używać Znacznik functions to pinpoint specific frequencies and measure their amplitość.

5.2 Vector Network Analysis (VNA)

The VNA mode allows for comprehensive characterization of RF components and networks by measuring S-parameters (S11, S21).

SIGLENT SVA1015X Vector Network Analysis Display

Figure 5.1: Display showing Vector Network Analysis results, including a Smith Chart for impedance matching and S-parameter measurements.

  1. Naciśnij Tryb button and select 'Vector Network Analyzer'.
  2. Perform a calibration using appropriate calibration kits (e.g., OSL mechanical calibration) to ensure accurate measurements.
  3. Connect the Device Under Test (DUT) to RF INPUT PORT 1 (for S11) or between PORT 1 and PORT 2 (for S21).
  4. Set the frequency range (Start/Stop Frequency) for the measurement. The SVA1015X supports VNA from 100 kHz to 1.5 GHz.
  5. Select the desired S-parameter (S11, S21) and display format (e.g., Log Magnitude, Phase, Smith Chart, Polar Chart, VSWR).
  6. The SVA1015X offers a transmission dynamic range of over 70 dB for single-port measurements.
  7. Utilize features like Distance-to-Fault (DTF) for cable and antenna testing, and impedance analysis for precise fault location.

5.3 EMI Pre-compliance Testing

The SVA1015X can be used for EMI pre-compliance testing, helping to identify potential electromagnetic interference issues early in the design cycle.

SIGLENT SVA1015X EMI Pre-compliance Test Setup Diagram

Figure 5.2: Diagram illustrating a typical setup for EMI pre-compliance testing using a Spectrum Analyzer/EMI Receiver, LISN, and attenuator.

5.4 Modulation Analysis

The SVA1015X offers advanced capabilities for analyzing modulated signals, supporting both analog and digital modulation types.

SIGLENT SVA1015X Modulation Analysis Display

Figure 5.3: Screen capture showing QAM modulation analysis, including constellation diagrams and various measurement parameters like EVM and IQ offset.

5.5 Pomiar mocy

The instrument provides a comprehensive suite of power measurement functions for characterizing RF signals.

SIGLENT SVA1015X Power Measurement Display

Figure 5.4: Graphical representation of various power measurement results, such as channel power and adjacent channel power ratio.

5.6 User Interface and Connectivity

SIGLENT SVA1015X 10.1 Inch Multi-Touch Display

Figure 5.5: The 10.1-inch multi-touch display of the SVA1015X, demonstrating touch-based interaction for setting parameters.

6. Konserwacja

6.1 Czyszczenie

6.2 Kalibracja

7. Rozwiązywanie Problemów

This section provides solutions to common issues encountered during the operation of the SVA1015X. If the problem persists, contact technical support.

ProblemMożliwa przyczynaRozwiązanie
Urządzenie nie włącza się.Power cord not connected; Power outlet faulty; Instrument fuse blown.Sprawdź połączenie przewodu zasilającego; Przetestuj gniazdko elektryczne; Skontaktuj się z serwisem w celu wymiany bezpiecznika.
No signal displayed in Spectrum Analyzer mode.Input signal not connected; Amplitude settings incorrect (e.g., Reference Level too low, Attenuation too high); Frequency range incorrect.Verify signal connection to RF INPUT PORT 1; Adjust Reference Level and Attenuation; Check Center Frequency and Span settings.
VNA measurements are inaccurate.Calibration not performed or incorrect; DUT not properly connected; Incorrect VNA settings.Perform a full VNA calibration; Ensure secure and correct DUT connections; Verify VNA frequency range and S-parameter settings.
Ekran dotykowy nie reaguje.Temporary software glitch; Screen dirty; Hardware issue.Restart the instrument; Clean the screen with a soft cloth; If issue persists, use external mouse/keyboard and contact support.

8. Specyfikacje

The following table outlines the key technical specifications for the SIGLENT SVA1015X Spectrum Vector Analyzer.

ParametrSpecification (SVA1015X)
Zakres częstotliwości analizatora widma9 kHz do 1.5 GHz
Vector Network Analyzer Frequency Range100 kHz do 1.5 GHz
Resolution Bandwidth (RBW)1 Hz to 1 MHz, in 1-3-10 sequence
Wyświetlany średni poziom hałasu (DANL)-156 dBm/Hz (typical)
Hałas fazowy<-98 dBc/Hz @ 1 GHz, 10 kHz offset
Całkowity AmpDokładność geograficzna<1.2 dB
Tracking Generator Frequency Range100 kHz do 1.5 GHz
Wyświetlacz10.1 Inch Multi-Touch Screen
Wymiary (dł. x szer. x wys.)18 x 12 x 11 cala
Waga12.05 funtów
Numer modelu przedmiotuSVA1015X
ProducentSiglent Technologies NA Inc.

9. Gwarancja i wsparcie

The SIGLENT SVA1015X is covered by a manufacturer's warranty. For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Siglent webstrona.

For technical support, service, or inquiries, please contact Siglent Technologies NA Inc. or your local authorized distributor. Contact information can typically be found on the Siglent webmiejscu lub w dokumentacji produktu.

Powiązane dokumenty - SVA1015X

Przedview Szybki przewodnik po generatorze przebiegów arbitralnych SIGLENT serii SDG3000X
W niniejszym skróconym przewodniku zawarto podstawowe informacje na temat generatora arbitralnego SIGLENT serii SDG3000X, w tym środki ostrożności, opisy paneli, podstawowe operacje i rozwiązywanie problemów.
Przedview Instrukcja obsługi generatora przebiegów arbitralnych SIGLENT serii SDG3000X
Kompleksowa instrukcja obsługi generatora arbitralnego SIGLENT serii SDG3000X, szczegółowo opisująca jego funkcje, obsługę, wytyczne dotyczące bezpieczeństwa i rozwiązywania problemów dla modeli SDG3202X, SDG3162X i SDG3082X.
Przedview SIGLENT SDG1000X Plus Series Arbitrary Waveform Generator User Manual
Comprehensive user manual for the SIGLENT SDG1000X Plus Series Arbitrary Waveform Generator, covering safety information, operation, settings, and support for models SDG1062X Plus, SDG1032X Plus, and SDG1022X Plus.
Przedview SIGLENT SSG3000X RF Signal Generator User Manual
Explore the SIGLENT SSG3000X RF Signal Generator with this comprehensive user manual. Learn about its features, operation, safety precautions, and troubleshooting for R&D, education, and production applications.
Przedview SIGLENT SSG50000A Signal Generator Quick Guide
This quick start guide provides essential information for operating the SIGLENT SSG50000A RF Signal Generator, including safety precautions, front and rear panel descriptions, user interface, firmware operations, and contact details.
Przedview Specyfikacje i funkcje generatora RF SIGLENT serii SSG3000X
Szczegółowe specyfikacje, funkcje i dane techniczne generatorów sygnału RF SIGLENT serii SSG3000X, w tym modeli SSG3032X, SSG3021X, SSG3032X-IQE i SSG3021X-IQE. Obejmują one charakterystykę częstotliwości, poziomu, modulacji i czystości widmowej.