ABB XT4NU3250EFF000XXX

Instrukcja obsługi wyłącznika kompaktowego ABB Tmax XT4NU3250EFF000XXX

Model: XT4NU3250EFF000XXX

1. Koniec produktuview

The ABB Tmax XT4NU3250EFF000XXX is a high-performance molded case circuit breaker designed for reliable protection in various electrical systems. This device features a frame size XT4, rated for up to 250A, with voltage ratings of 600V (UL) and 690V (IEC). It incorporates an Ekip LS/I electronic trip unit, providing Long-Time (L), Short-Time (S), and Instantaneous (I) protection functions. This 3-pole circuit breaker is engineered for safety and efficiency in industrial and commercial applications.

ABB Tmax XT4NU3250EFF000XXX Molded Case Circuit Breaker

An image showing the ABB Tmax XT4NU3250EFF000XXX Molded Case Circuit Breaker. The device is dark gray with a red and white handle, indicating its operational status. Various labels and connection points are visible on its front and sides.

2. Informacje dotyczące bezpieczeństwa

Aby zapobiec obrażeniom ciała lub uszkodzeniu sprzętu, należy zawsze przestrzegać następujących środków ostrożności:

  • Installation, maintenance, and repair must be performed by qualified personnel only.
  • Ensure all power sources are disconnected and locked out before working on the circuit breaker or associated circuitry.
  • Use appropriate personal protective equipment (PPE) such as insulated gloves, safety glasses, and arc-flash protective clothing.
  • Sprawdź poprawność objętościtage i prąd znamionowy przed instalacją.
  • Do not operate the circuit breaker if it appears damaged or malfunctioning.

3. Konfiguracja i instalacja

The ABB Tmax XT4NU3250EFF000XXX circuit breaker is designed for DIN Rail Mount installation. Proper installation is crucial for safe and reliable operation.

3.1 Kontrole przed instalacją

  • Sprawdź, czy wyłącznik automatyczny nie ma uszkodzeń fizycznych.
  • Confirm that the product specifications match the system requirements.
  • Ensure the mounting surface is clean and secure.

3.2 Montaż

  1. Securely attach the circuit breaker to a standard DIN rail.
  2. Zapewnij odpowiednią wentylację wokół urządzenia, aby zapobiec przegrzaniu.

3.3 Okablowanie

  • Connect the main power supply conductors to the appropriate terminals (Line/Load) as indicated on the device.
  • Ensure all connections are tight and secure to prevent loose contacts and arcing.
  • Follow all local and national electrical codes for wiring practices.
  • Verify correct polarity and phase sequence for multi-phase installations.

4. Instrukcja obsługi

The ABB Tmax XT4NU3250EFF000XXX circuit breaker is designed for straightforward operation.

4.1 Włączanie/wyłączanie

  • To Switch ON: Push the operating handle firmly to the 'ON' position.
  • To Switch OFF: Push the operating handle firmly to the 'OFF' position.

4.2 Wskaźnik i resetowanie wyłącznika czasowego

  • If an overload or short-circuit occurs, the circuit breaker will automatically trip, moving the handle to an intermediate 'TRIPPED' position.
  • Aby zresetować: First, move the handle fully to the 'OFF' position. Then, push the handle to the 'ON' position.
  • Before resetting, investigate and resolve the cause of the trip. Repeated tripping indicates an underlying electrical issue.

5. Konserwacja

Regular maintenance ensures the longevity and reliable operation of your circuit breaker.

5.1 Rutynowa kontrola

  • Okresowo należy sprawdzać wyłącznik automatyczny pod kątem uszkodzeń fizycznych, przebarwień lub luźnych połączeń.
  • Check for dust accumulation and keep the area around the breaker clean.

5.2 Czyszczenie

  • Przed czyszczeniem należy upewnić się, że zasilanie jest odłączone.
  • Use a dry, lint-free cloth to wipe down the exterior of the circuit breaker. Avoid using solvents or abrasive cleaners.

5.3 Serwis profesjonalny

For internal inspection, testing, or repair, contact qualified ABB service personnel or an authorized service center. Do not attempt to disassemble the circuit breaker yourself.

6. Rozwiązywanie Problemów

W tej sekcji znajdziesz wskazówki dotyczące typowych problemów. W przypadku skomplikowanych problemów skonsultuj się z wykwalifikowanym elektrykiem.

6.1 Breaker Trips Frequently

  • Możliwa przyczyna: Przeciążać.
  • Działanie: Reduce the load on the circuit by unplugging some devices.
  • Możliwa przyczyna: Zwarcie.
  • Działanie: Inspect wiring and connected devices for faults. This requires professional attention.
  • Możliwa przyczyna: Ground fault (if applicable to the specific trip unit configuration).
  • Działanie: Consult a qualified electrician to identify and rectify the ground fault.

6.2 Breaker Will Not Reset

  • Możliwa przyczyna: Persistent fault (overload or short circuit).
  • Działanie: Ensure the cause of the trip has been resolved. If the fault persists, the breaker will not reset.
  • Możliwa przyczyna: Internal damage to the breaker.
  • Działanie: If no fault is present and the breaker still won't reset, it may be damaged and require replacement by a qualified professional.

7. Specyfikacje

Detailed technical specifications for the ABB Tmax XT4NU3250EFF000XXX Molded Case Circuit Breaker:

SpecyfikacjaWartość
MarkaWĄTEK
ModelXT4NU3250EFF000XXX
Obecna ocena250 Amps
Tomtage Rating (UL)600 V
Tomtage Rating (IEC)690 V
Typ podróżyEkip LS/I (Electronic, LS/I Protection)
Liczba biegunów3
Typ wyłącznika automatycznegoLS
Typ montażuMontaż na szynie DIN
Wymiary opakowania8.26 x 6.49 x 6.1 cala
Waga5.51 funtów
Data pierwszej dostępności25 czerwca 2018 r.

8. Informacje o gwarancji

ABB products are manufactured to high standards and typically come with a manufacturer's warranty. For specific warranty terms and conditions applicable to your ABB Tmax XT4NU3250EFF000XXX circuit breaker, please refer to the official documentation provided with your purchase or visit the official ABB webZachowaj dowód zakupu na wypadek roszczeń gwarancyjnych.

9. Wsparcie i kontakt

For technical assistance, product inquiries, or service requests, please contact ABB customer support. You can find contact information and additional resources on the official ABB webstrona.

Oficjalny przedstawiciel ABB Webstrona: Visit the ABB Store on Amazon

Always provide the full model number (XT4NU3250EFF000XXX) when contacting support to ensure accurate assistance.

Powiązane dokumenty - XT4NU3250EFF000XXX

Przedview Katalog ABB SACE Tmax XT: Niska objętośćtage Wyłączniki kompaktowe
Poznaj serię ABB SACE Tmax XT, najnowocześniejszą gamę urządzeń o niskiej objętościtagWyłączniki kompaktowe o konstrukcji formowanej, zapewniające doskonałą wydajność, łączność, łatwość użytkowania i solidną ochronę w różnych zastosowaniach przemysłowych i komercyjnych.
Przedview ABB SACE Emax 2 Low Voltage Katalog techniczny wyłączników pneumatycznych
Comprehensive technical catalogue detailing ABB's SACE Emax 2 series of low voltage air circuit-breakers, covering features, specifications, protection, connectivity, and accessories for advanced electrical distribution systems.
Przedview Instalacja i dane techniczne wyłącznika nadprądowego ABB Tmax T5
Kompleksowe specyfikacje techniczne, rysunki wymiarowe i wytyczne montażowe dla wyłączników ABB Tmax T5, ​​obejmujących różne serie, np. PR221DS.
Przedview SACE Tmax XT Circuit Breaker Installation Guide
Comprehensive installation instructions and recommended conditions for ABB SACE Tmax XT circuit breakers, covering AC and DC applications, wiring diagrams, dimensional data, and trip test procedures.
Przedview ABB SACE Emax 2: Nowa niska objętośćtage Katalog techniczny wyłączników pneumatycznych
Poznaj nową serię urządzeń ABB SACE Emax 2 o niskiej objętościtage air circuit-breakers. This technical catalogue provides detailed information on features, ranges, protection trip units, communication, accessories, and specifications for efficient power management and system reliability.
Przedview ABB SACE Tmax Generacja T: Niska objętośćtage Wyłączniki kompaktowe (250A-1600A) Katalog techniczny
Poznaj gamę produktów ABB SACE Tmax T Generation o małej objętościtagWyłączniki kompaktowe, zaprojektowane z myślą o solidnej ochronie elektrycznej i niezawodnym rozprowadzaniu prądu od 250 A do 1600 A. W niniejszym katalogu technicznym szczegółowo opisano cechy, specyfikacje i zastosowania.