1. Wprowadzenie
The OWON XDS2102A is a 2-channel, 12-bit high-resolution digital oscilloscope designed for precise signal analysis. It features a 100MHz bandwidth, 1GS/s real-time sample rate, and a 20M record length, making it suitable for various measurement applications. The device offers a 55,000 wfms/s waveform refresh rate for capturing transient events and includes multi-trigger and serial bus decoding functions (SPI, I2C, RS232, CAN).
2. Informacje dotyczące bezpieczeństwa
Before operating the OWON XDS2102A oscilloscope, please read and understand all safety instructions. Failure to follow these instructions may result in injury or damage to the instrument. Always connect the instrument to a properly grounded power source. Do not operate the device in wet or damp conditions. Ensure proper ventilation to prevent overheating. Refer all servicing to qualified personnel.
3. Zawartość opakowania
Sprawdź, czy w przesyłce znajdują się wszystkie wymienione poniżej elementy:
- OWON XDS2102A Digital Oscilloscope
- Przewód zasilający (x1)
- CD-ROM (x1)
- Krótki przewodnik (x1)
- Kabel USB (x1)
- Sondy oscyloskopowe (x2)
- Probe Adjustment Tool (x1)
4. Koniec produktuview
The OWON XDS2102A features an intuitive front panel layout and a range of connectivity options.
4.1 Panel przedni
The front panel includes an 8-inch 800x600 high-resolution LCD for waveform display, along with various control buttons and knobs for instrument operation.

This image displays the OWON XDS2102A digital oscilloscope from a front-right angle. The device features an 8-inch color LCD screen showing two waveforms: a yellow sine wave and a blue square wave. The front panel is equipped with numerous control knobs and buttons for various functions, including vertical and horizontal adjustments, triggering, and menu navigation. Input connectors for channels CH1, CH2, and EXT Trig are visible at the bottom right. A USB host port is located below the screen.
Do kluczowych kontroli należą:
- Gałka wielofunkcyjna: For menu navigation and parameter adjustment.
- Przyciski funkcyjne: Such as Menu Off, Run/Stop, Single, Acquire, Autoset, Utility, Cursor, Save, Display, Help, Math.
- Sterowanie pionowe: Position and Scale knobs for CH1 and CH2.
- Sterowanie poziome: Position and Scale knobs for time base adjustment.
- Złącza wejściowe: BNC connectors for CH1, CH2, and EXT Trig.
- Port hosta USB: For data storage and firmware updates.
- Przycisk zasilania: Aby włączyć lub wyłączyć urządzenie.
4.2 Panel tylny
The rear panel provides additional connectivity:
- Port VGA: For external display connection, useful for presentations or larger viewing.
- Port LAN: Do łączności sieciowej i zdalnego sterowania.
- Port AUX: Auxiliary output.
- Port urządzenia USB: Do podłączenia do komputera.
- USB Port for PictBridge: For direct printing to compatible printers.
5. Konfiguracja
Follow these steps to set up your oscilloscope:
- Podłączenie zasilania: Connect the provided power cord to the oscilloscope's power input and then to a grounded AC power outlet.
- Połączenie sondy: Connect the oscilloscope probes to the CH1 and/or CH2 BNC input connectors. Ensure the probe's ground clip is securely connected to the circuit's ground.
- Kompensacja sondy: For accurate measurements, compensate your probes. Connect the probe tip to the oscilloscope's probe compensation output (usually a square wave signal) and the ground clip to the ground terminal. Adjust the trimmer on the probe until the square wave displayed on the screen has flat tops and bottoms without overshoot or undershoot.
- Włączanie: Aby włączyć oscyloskop, naciśnij przycisk zasilania na panelu przednim.
6. Instrukcja obsługi
This section covers basic operation of the OWON XDS2102A oscilloscope.
6.1 Pomiary podstawowe
- Automatyczne ustawianie: Naciśnij Automatyczne ustawianie button to automatically adjust the vertical, horizontal, and trigger settings for a stable display of most signals.
- Vertical Scale and Position: Użyj Skala knobs for CH1 and CH2 to adjust the vertical sensitivity (Volts/division). Use the Pozycja knobs to move the waveform vertically on the screen.
- Horizontal Scale and Position: Use the horizontal Skala knob to adjust the time base (seconds/division). Use the horizontal Pozycja pokrętło do przesuwania przebiegu w poziomie.
6.2 Wyzwalanie
Wyzwalanie stabilizuje powtarzające się przebiegi i wychwytuje pojedyncze zdarzenia.
- Tryb wyzwalania: The XDS2102A supports various trigger modes. The default is typically Edge trigger.
- Źródło wyzwalacza: Select the input channel (CH1, CH2, EXT Trig) or AC Line as the trigger source.
- Trigger Coupling: Options include DC, AC, Noise Reject, HF Reject, LF Reject.
- Nachylenie wyzwalacza: Choose between rising edge, falling edge, or both.
- Poziom wyzwalania: Ustaw pokrętło poziomu wyzwalania, aby ustawić głośnośćtage threshold at which the trigger occurs.
6.3 Bus Decoding
The oscilloscope supports decoding for common serial bus protocols.
- Access the bus decoding function through the menu.
- Select the desired protocol (SPI, I2C, RS232, CAN).
- Configure the relevant parameters for the chosen bus, such as clock source, data source, and thresholds.
7. Konserwacja
Właściwa konserwacja gwarantuje długowieczność i dokładność oscyloskopu.
- Czyszczenie: Use a soft, dry cloth to clean the exterior of the instrument. For stubborn dirt, use a cloth lightly dampened with water or a mild detergent. Do not use abrasive cleaners or solvents.
- Pielęgnacja sondy: Handle probes carefully. Avoid bending the probe cable sharply. Store probes in a clean, dry environment.
- Składowanie: When not in use, store the oscilloscope in a cool, dry place, away from direct sunlight and extreme temperatures.
8. Rozwiązywanie Problemów
If you encounter issues with your OWON XDS2102A, refer to the following common troubleshooting tips:
- Brak zasilania: Ensure the power cord is securely connected to both the oscilloscope and a working power outlet. Check the power switch position.
- Brak sygnału: Verify that the input signal is connected correctly to the BNC input. Check probe connections and compensation. Adjust vertical scale and position. Ensure the trigger level is set appropriately. Try pressing the Automatyczne ustawianie przycisk.
- Zniekształcona forma fali: Check probe compensation. Ensure the input signal amplitude does not exceed the oscilloscope's input range. Verify proper grounding.
- Niestabilna forma fali: Adjust trigger settings (source, level, slope, mode) to achieve a stable display.
Jeśli problemy będą się powtarzać, skontaktuj się z obsługą klienta w celu uzyskania pomocy.
9. Specyfikacje
| Funkcja | Specyfikacja |
|---|---|
| Model | XDS2102A |
| Kanały | 2 |
| Przepustowość łącza | 100MHz |
| Sampstawka | 1 GS/s (w czasie rzeczywistym) |
| Rezolucja | 12-bitowy przetwornik analogowo-cyfrowy |
| Długość rekordu | 20 mln punktów |
| Częstotliwość odświeżania przebiegu | 55,000 XNUMX połączeń na sekundę |
| Czułość pionowa | 1 mV/dz - 10 V/dz |
| Wyświetlacz | 8-calowy wyświetlacz LCD, rozdzielczość 800 x 600 |
| Interfejsy | USB Host, USB Device, USB for PictBridge, LAN, AUX, VGA |
| Wymiary (dł. x szer. x wys.) | 13.39 x 7.09 x 3.54 cala |
| Waga przedmiotu | 6.98 funta |
| Tworzywo | Plastikowy |
10. Gwarancja i wsparcie
For warranty information and technical support, please refer to the documentation provided with your purchase or contact the authorized OWON distributor or seller. Specific warranty terms may vary by region and retailer. Keep your proof of purchase for warranty claims.