1. Wprowadzenie
Thank you for choosing the Knightsbridge CU4200 Curved Edge 10A 6 Gang 2 Way Switch. This manual provides essential information for the safe installation, operation, and maintenance of your new electrical switch. Please read these instructions carefully before installation and retain them for future reference.
2. Informacje dotyczące bezpieczeństwa
OSTRZEŻENIE: Electricity can be dangerous. Installation must be carried out by a qualified electrician or competent person in accordance with the latest IEE Wiring Regulations (BS7671) and local building regulations.
- Always isolate the mains power supply before commencing any electrical work.
- Ensure the circuit is dead using a suitable voltagtester przed dotknięciem jakichkolwiek przewodów.
- Produkt przeznaczony jest wyłącznie do użytku wewnątrz pomieszczeń.
- Do not exceed the rated current of 10 Ampsą.
- Sprawdź, czy wszystkie połączenia są solidne i prawidłowo podłączone.
- W razie wątpliwości należy skonsultować się z wykwalifikowanym elektrykiem.
3. Zawartość opakowania
Sprawdź, czy wszystkie elementy są obecne i nieuszkodzone:
- 1 x Knightsbridge CU4200 6 Gang 2 Way Switch Unit
- 2 x śruby mocujące
4. Koniec produktuview
The Knightsbridge CU4200 is a 6-gang, 2-way light switch designed for controlling up to six separate lighting circuits from one or two locations. It features a curved edge design and a white finish.

Rysunek 1: Przód view of the Knightsbridge CU4200 6 Gang 2 Way Switch. This image shows the white faceplate with six individual rocker switches arranged in two rows of three.

Rysunek 2: Tył view of the switch unit, displaying the terminal blocks for electrical connections. Each switch module has terminals labeled 'COM', 'L1', and 'L2'. The text 'MADE IN CHINA' is visible.

Rysunek 3: Detailed close-up of the wiring terminals. Each switch module clearly shows screw terminals for 'COM' (Common), 'L1' (Switched Live 1), and 'L2' (Switched Live 2), indicating its 2-way functionality. The rating '10AX 250V' is also visible.

Rysunek 4: Technical drawing illustrating the dimensions of the switch. The drawing indicates a width of 146mm, a height of 86mm, and a depth of 21mm to the back base.
5. Instalacja
Zanim zaczniesz: Ensure the mains power supply to the circuit you are working on is switched off at the consumer unit/fuse box and secured against accidental re-connection. Use a suitable voltagtester, aby potwierdzić, że obwód jest martwy.
Wiring Instructions (2-Way Switching)
The CU4200 is a 2-way switch, meaning each gang can control a light from two different locations. Refer to Rysunek 2 I Rysunek 3 for terminal identification.
- Przygotuj przewody: Carefully strip the insulation from the ends of the circuit wires (Live, Neutral, Earth, and Switched Lives/Strappers) to expose approximately 10-12mm of copper conductor.
- Połączenie uziemiające: Connect the bare copper or green/yellow insulated Earth wire from the circuit to the Earth terminal on the back box (if applicable) and ensure continuity. The switch itself does not have an Earth terminal as it is a Class II product (double insulated), but the metal back box must be earthed.
- Common (COM) Connection: For each switch gang, connect the permanent live wire (usually brown or red) to the 'COM' terminal. If multiple gangs share a common live feed, a short link wire may be used between the 'COM' terminals of adjacent switches.
- Switched Live (L1 & L2) Connections:
- For 2-Way Switching: Connect the two 'strapping' wires (often brown with red/yellow sleeves or grey/black) between the 'L1' and 'L2' terminals of this switch and the corresponding 'L1' and 'L2' terminals of the other 2-way switch controlling the same light.
- The switched live wire going to the light fitting should be connected to either 'L1' or 'L2' on one of the 2-way switches (typically the one where the light feed originates).
- Bezpieczne połączenia: Ensure all wires are fully inserted into their respective terminals and the terminal screws are tightened firmly. Tug gently on each wire to confirm it is secure.
- Montowanie: Carefully position the switch unit into the wall box, ensuring no wires are trapped or pinched. Secure the switch to the wall box using the provided fixing screws.
- Przedni panel: Attach the faceplate to the switch unit.
- Przywróć zasilanie: Once installation is complete and all connections are checked, restore the mains power supply at the consumer unit/fuse box.
6. Instrukcja obsługi
To operate the switch, simply press the top or bottom of each rocker switch to toggle the connected light circuit on or off. In a 2-way setup, the light can be switched from either the CU4200 or the other connected 2-way switch.
7. Konserwacja
The Knightsbridge CU4200 switch requires minimal maintenance. To clean the surface, wipe with a soft, dry cloth. Do not use abrasive cleaners, solvents, or polishes as these may damage the finish. Ensure power is off before cleaning.
8. Rozwiązywanie Problemów
If the switch is not functioning correctly, consider the following:
- Brak zasilania: Check the circuit breaker or fuse at the consumer unit. Ensure all wiring connections are secure and correct (refer to Section 5).
- Działanie przerywane: Loose wiring connections are a common cause. Isolate power and re-check all terminal screws.
- Przełącznik wydaje się luźny: Ensure the fixing screws securing the switch to the wall box are tightened.
If problems persist after checking these points, consult a qualified electrician.
9. Specyfikacje
| Model | CU4200 |
| Typ | 6 Gang, 2 Way Switch |
| Obecna ocena | 10 Amperes (AX) |
| Tomtage Ocena | 250 V~ |
| Wymiary (dł. X szer. X gł.) | 14.6 cm x 8.6 cm x 2.1 cm (approximate depth to back base) |
| Waga | 130 gramów |
| Tworzywo | Plastic (White finish) |
| Normy | Norma PN-EN 60669-1 |
10. Gwarancja i wsparcie
This product is manufactured to high standards and is covered by a standard manufacturer's warranty. For specific warranty details, technical support, or to report any issues, please contact Knightsbridge customer service or refer to their official website. Please have your model number (CU4200) and purchase information available when contacting support.
Knightsbridge Contact Information: Please visit the official Knightsbridge webna tej stronie znajdziesz najbardziej aktualne dane kontaktowe.