Olimpia Splendid 01802

Olimpia Splendid 01802 Unico Air Inverter 10 HP Fixed Air Conditioner

Instrukcja obsługi

Produkt ponadview

The Olimpia Splendid 01802 Unico Air Inverter 10 HP is a fixed air conditioning unit designed for both cooling and heating, featuring an inverter system and operating without an external outdoor unit. This manual provides essential information for its proper installation, operation, and maintenance.

Olimpia Splendid 01802 Unico Air Inverter 10 HP fixed air conditioner, front view

Rycina 1: Przód view of the Olimpia Splendid 01802 Unico Air Inverter 10 HP unit.

Olimpia Splendid 01802 Unico Air Inverter 10 HP installed in a modern living space

Figure 2: The Unico Air Inverter 10 HP unit seamlessly integrated into a room environment.

Zawarte komponenty

Sprawdź, czy w opakowaniu znajdują się wszystkie elementy:

  • Olimpia Splendid 01802 Fixed Air Conditioning Unit
  • 1 x Self-adhesive insulation strip
  • 2 x External grilles for air intake and outlet, including chain and installation kit (2 pieces)
  • 2 x Internal flanges
  • Wall pipes
  • Screws and wall plugs set
  • Uchwyt ścienny
  • Zdalne sterowanie
  • Paper template for drilling
  • User and Maintenance Manual (this document) + Warranty information

Konfiguracja i instalacja

Ważny: Installation of this unit requires specific technical skills. Professional installation is strongly recommended to ensure proper functioning and safety. The following steps are for informational purposes only and should be performed by qualified personnel.

  1. Pozycjonowanie: Select a suitable wall for installation. The unit must be installed on an external perimeter wall.
  2. Wiercenie: Create two holes in the wall using a core drill, following the dimensions provided in the drilling template.
  3. Grille Insertion: Insert the special self-locking grilles of the UNICO unit into the drilled holes.
  4. Montowanie: Secure the UNICO unit to the wall using the provided wall bracket and screws.
  5. Połączenie rurowe: Connect the wall pipes as per the installation diagram.
Installation diagram showing drilling, pipe insertion, and unit mounting for Olimpia Splendid 01802

Figure 3: Installation steps including drilling, pipe insertion, and unit mounting. Professional installation is advised.

External grilles for air intake and outlet of Olimpia Splendid 01802

Figure 4: External grilles for air intake and outlet, designed for discreet outdoor appearance.

Olimpia Splendid 01802 Unico Air Inverter 10 HP unit installed on a wall, showing minimal external impact

Figure 5: The Unico unit installed, demonstrating its minimal external impact with only two small grilles visible.

Instrukcja obsługi

The Olimpia Splendid 01802 unit offers various operating modes to suit your comfort needs. All functions are controlled via the supplied remote control.

Tryby pracy:

  • Tryb chłodzenia: Provides cooling to lower room temperature.
  • Tryb ogrzewania: Utilizes a heat pump to warm the room.
  • Tryb wentylatora: Cyrkuluje powietrze bez chłodzenia i ogrzewania.
  • Tryb osuszacza: Zmniejsza poziom wilgotności w pomieszczeniu.
  • Tryb ekonomiczny: Optimizes energy consumption for cost-effective operation.
  • Tryb uśpienia: Adjusts temperature and fan speed for comfortable sleep while reducing noise.
  • Tryb automatyczny: Automatically selects the appropriate operating mode (cooling, heating, or fan) based on the ambient temperature.

Refer to the remote control section in the full manual for detailed instructions on selecting modes and adjusting settings.

Konserwacja

Regular maintenance ensures the longevity and efficient operation of your Olimpia Splendid 01802 unit.

Czyszczenie filtra:

The unit is equipped with a pre-filter. Clean the filter regularly to maintain optimal air quality and unit performance. Refer to the full manual for instructions on how to access and clean the filter.

Odprowadzanie kondensatu:

In cooling mode, condensate is automatically drained. For heating mode, a condensate drain pipe may be necessary. Ensure the condensate drainage system is clear and free from obstructions.

Rozwiązywanie problemów

If you encounter issues with your Olimpia Splendid 01802 unit, consult the following basic troubleshooting steps. For more complex problems, refer to the comprehensive troubleshooting guide in the full user manual or contact customer support.

  • Jednostka się nie włącza: Check if the unit is properly plugged into a power outlet and if the circuit breaker has tripped.
  • Niewystarczające chłodzenie/ogrzewanie: Ensure all windows and doors are closed. Check if the air filters are clean. Verify that the correct operating mode and temperature settings are selected.
  • Niezwykłe dźwięki: Minor operational noises are normal. If you hear loud or unusual noises, turn off the unit and contact technical assistance.
  • Wyciek wody: Check the condensate drain for blockages. Ensure the unit is installed correctly and level.

Specyfikacje

Detailed technical specifications for the Olimpia Splendid 01802 Unico Air Inverter 10 HP unit:

FunkcjaSpecyfikacja
Numer modelu01802
MarkaOlimpia Wspaniała
Tryby pracyEconomy, Cooling, Heating, Fan, Dehumidifier, Sleep, Automatic
Klasa efektywności energetycznejA
Nominalna moc chłodzenia2.3 kW
Nominal Heating Power2.0 kW
EER (współczynnik efektywności energetycznej)2.6
COP (współczynnik wydajności)3.1
Poziom ciśnienia akustycznego27-38 dB(A)
ChłodziwoR410A (0.36 kg)
Wymiary produktu (dł. x szer. x wys.)Wymiary 97.8 x 16.4 x 49.1 cm
Waga41 kilogramów
Tomtage240 wolty
Typ filtraFiltr wstępny
Cechy specjalneCooling function, Dehumidifier, Heating and cooling function
Dimensions diagram for Olimpia Splendid 01802 Unico Air Inverter 10 HP

Figure 6: Dimensional drawing of the Olimpia Splendid 01802 unit.

Energy label and technical data sheet for Olimpia Splendid Unico Air Inverter 10 HP

Figure 7: Energy label and detailed technical specifications for the Unico Air Inverter 10 HP.

Gwarancja i wsparcie

Olimpia Splendid offers an extended warranty beyond statutory terms. This warranty is easy to activate online and provides guaranteed service directly from the manufacturer, managed by a network of qualified technical assistance centers.

For warranty activation details, terms, and conditions, please refer to the technical specifications provided with your product or visit the official Olimpia Splendid webstrona.

Product documentation, including technical details, user manuals, and installation guides, can be downloaded from the manufacturer's webwitrynę w obszarze pobierania.

For technical assistance or support, please contact your local authorized service center or visit the Olimpia Splendid support portal.

Powiązane dokumenty - 01802

Przedview Olimpia Splendid UNICO EVO-F Air Conditioner User Manual
Comprehensive guide for the Olimpia Splendid UNICO EVO-F air conditioner, covering installation, usage, maintenance, safety warnings, and technical specifications. Learn how to operate and care for your UNICO EVO-F unit.
Przedview Olimpia Splendid UNICO PRO INVERTER User Manual and Installation Guide
Comprehensive guide for the Olimpia Splendid UNICO PRO INVERTER air conditioner, covering installation, operation, maintenance, and safety instructions to ensure optimal performance and longevity.
Przedview Olimpia Splendid UNICO AIR Installation and User Manual
Comprehensive guide for the installation, use, and maintenance of the Olimpia Splendid UNICO AIR air conditioning unit. Includes safety warnings, component lists, operational instructions, and troubleshooting tips.
Przedview Olimpia Splendid UNICO AIR R410A ON/OFF User Manual
This document provides comprehensive instructions for the use and maintenance of the Olimpia Splendid UNICO AIR R410A ON/OFF air conditioning unit. It covers general information, product description, installation guidelines, operating instructions, cleaning, maintenance, and technical data.
Przedview Manuale d'Uso e Manutenzione Olimpia Splendid UNICO NEXT EVAN
Zainstaluj, użyj i zarządzaj klimatyzatorem Olimpia Splendid UNICO NEXT EVAN z tą pełną instrukcją. Dołącz instrukcje di sicurezza, przewodnik operacyjny i porady dla il risparmio energio.
Przedview Instrukcja obsługi klimatyzatorów mobilnych POLAR12, POLAR14, POLAR16 – Olimpia Splendid – przewodnik po klimatyzatorach mobilnych
Kompleksowa instrukcja obsługi mobilnych klimatyzatorów Olimpia Splendid POLAR12, POLAR14 i POLAR16. Obejmuje funkcje, instalację, obsługę, bezpieczeństwo, konserwację i rozwiązywanie problemów.