Wstęp
This instruction manual provides detailed guidance for the installation, operation, and maintenance of the Juno 6-Inch Incandescent Recessed Light Housing, Model IC22 W G. This housing is specifically designed for new construction applications and is engineered for safety, performance, and energy efficiency.
Główne cechy obejmują:
- IC-Rated: Nadaje się do bezpośredniego kontaktu z izolacją.
- Na liście UL: Certified for damp locations, ensuring safety and reliability.
- Air-Loc Gasket: Integrated gasket reduces air leakage, contributing to energy efficiency.
- Łatwa instalacja: Features push-in electrical connectors and Real Nail 3 bar hangers for secure mounting.
- Wszechstronny: Accommodates various incandescent lamp types and trim combinations.
Informacje dotyczące bezpieczeństwa
Always disconnect power at the circuit breaker before installing or servicing the fixture. Installation should be performed by a qualified electrician in accordance with national and local electrical codes. Ensure the housing is properly grounded.
This housing is Ocena IC, meaning it is safe for direct contact with insulation. It is also Na liście UL dla damp lokalizacje, making it suitable for bathrooms, kitchens, and other areas where moisture may be present.
Konfiguracja i instalacja
The Juno IC22 W G housing is designed for new construction projects and fits ceilings up to 1 inch thick. Follow these general steps for installation:
- Przygotuj sufit: Ensure the ceiling joists are properly spaced to accommodate the housing's bar hangers. The housing requires a 6-7/8 inch ceiling cutout.
- Zamontuj obudowę: Utilize the Real Nail 3 bar hangers with telescoping arms to securely mount the galvanized steel frame between ceiling joists. The hangers are designed for quick and stable positioning.
- Okablowanie: The pre-wired junction box includes (5) 1/2 inch and (1) 3/4 inch knockouts. Use the provided push-in electrical connectors to simplify wiring connections. Ensure all connections are secure and comply with electrical codes.
- Install Socket and Trim: The housing features an adjustable socket plate and a detachable medium base porcelain socket with snap-in springs. This allows for accommodation of various lamp and trim combinations. Install the desired incandescent bulb and compatible Juno 6-inch baffle trim (sold separately).



Instrukcja obsługi
The Juno IC22 W G is a housing unit designed to hold an incandescent light bulb and a compatible trim. Its operation is dependent on the installed bulb and the electrical circuit it is connected to.
- Kompatybilność żarówek: This housing accepts incandescent lamp types including A19, BR30, BR40, R20, PAR16, PAR20, and PAR30. Ensure the wattage of the chosen bulb does not exceed the maximum rating of the fixture (90 watts).
- Regulacja mocy: The light will operate via the wall switch or control method connected to its electrical circuit.
Konserwacja
Regular maintenance ensures optimal performance and longevity of your recessed light housing.
- Czyszczenie: Periodically clean the trim and bulb with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Wymiana żarówki: Always disconnect power before replacing a bulb. Allow the old bulb to cool completely before removal. Insert the new bulb securely into the medium base porcelain socket, ensuring it is of a compatible type and wattage.
- Kontrola: Annually inspect the housing and wiring for any signs of wear, damage, or loose connections. If any issues are found, consult a qualified electrician.
Rozwiązywanie problemów
If you encounter issues with your Juno recessed light housing, consider the following common troubleshooting steps:
- Światło nie włącza się:
- Sprawdź wyłącznik automatyczny, aby upewnić się, że do urządzenia jest dostarczane zasilanie.
- Verify the light bulb is correctly installed and not burnt out. Try replacing it with a known working bulb.
- Upewnij się, że przełącznik ścienny jest w pozycji „ON”.
- Migoczące światło:
- Confirm the bulb is fully screwed into the socket.
- Check for loose wiring connections in the junction box (ensure power is off before inspecting).
- Upewnij się, że żarówka ma wattage is compatible with the fixture and any dimmer switches used.
- Przegrzanie:
- Upewnij się, że żarówka ma odpowiednią moctage is used and does not exceed the fixture's maximum rating.
- Verify that the IC-rated housing is not compromised and insulation is not directly touching non-IC rated parts (if applicable, though this model is IC-rated).
For persistent electrical issues or if you are unsure about any troubleshooting steps, consult a qualified electrician.
Specyfikacje
| Atrybut | Szczegół |
|---|---|
| Numer modelu | IC22 W G |
| Rozmiar | 6 cali |
| Typ instalacji | New Construction, Recessed |
| Tworzywo | Galvanized Steel Frame, Copper (internal components) |
| Wymiary (produkt) | 14"L x 14"W x 8"H (overall with hangers) |
| Wycięcie sufitowe | 6-7/8 cala |
| Grubość sufitu | Do 1 cala |
| Typ źródła światła | Rozżarzony |
| Podstawa żarówki | E26 średni |
| Maksymalna moctage | 90 watów |
| Tomtage | 120 wolty |
| Certyfikaty | UL Listed, CSA, IC-Rated, Damp Lokalizacja |
| Waga | 2.5 funta |
| Zawarte komponenty | Mieszkania |
Gwarancja i wsparcie
The Juno 6 Inch Incandescent Recessed Light Housing (Model IC22 W G) comes with a 5-roczna ograniczona gwarancja. Please note that using trim kits from other brands may void the warranty.
For technical assistance, warranty claims, or further information, please contact Juno customer support. Refer to the official Juno webna stronie internetowej lub opakowaniu produktu, aby uzyskać najaktualniejsze dane kontaktowe.