Wstęp
This manual provides essential instructions for the safe and efficient use of your Techly Professional 023189 Vertical Rack Power Strip. Please read this manual thoroughly before installation and operation, and retain it for future reference.
The Techly Professional 023189 is a 12-outlet vertical rack-mountable power distribution unit (PDU) designed for professional environments. It features Schuko outlets, a thermal-magnetic circuit breaker for overload protection, and a durable aluminum and black finish.
Informacje dotyczące bezpieczeństwa
WARNING: To reduce the risk of electric shock, fire, or injury, always follow basic safety precautions when using electrical products.
- Do not exceed the maximum load capacity of 3.5 kW (16 A, 250 V AC).
- Produkt przeznaczony jest wyłącznie do użytku wewnątrz pomieszczeń.
- Nie należy podłączać do siebie kilku listew zasilających.
- Ensure the power strip is properly grounded.
- Do not open or modify the device. Refer all servicing to qualified personnel.
- Trzymać z dala od wody i środowisk o dużej wilgotności.
- Ensure proper ventilation when installed in a rack.
Zawartość opakowania
Sprawdź, czy wszystkie elementy są obecne i nieuszkodzone:
- Techly Professional 023189 Vertical Rack Power Strip (12 Schuko outlets)
- Instrukcja obsługi
Image: The product packaging box, labeled "TECHLY PROFESSIONAL 19" Power Distribution Unit".
Produkt ponadview
The Techly Professional 023189 is a robust power distribution unit designed for vertical mounting in 19-inch server racks. It provides 12 Schuko outlets for connecting various electrical devices.
Obraz: Pełny view of the Techly Professional 023189 power strip, showing 12 Schuko outlets, the circuit breaker, and mounting brackets.
Główne cechy:
- 12 Schuko (IEC60884) outlets angled at 45°
- Integrated thermal-magnetic circuit breaker for overload protection
- Vertical rack-mountable design
- 3-meter power cable with angled Schuko plug
- Durable aluminum and black finish
- Maximum load capacity: 3.5 kW (16 A, 250 V AC)
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in an open position, revealing the blue switch and "I ON / O OFF" markings.
Obraz: szczegółowy view of the angled Schuko power plug, which connects the power strip to the main power source.
Konfiguracja i instalacja
- Rozpakuj listwę zasilającą: Carefully remove the power strip from its packaging. Inspect for any signs of damage.
- Wybierz miejsce montażu: Select a suitable vertical location within a standard 19-inch server rack. Ensure there is adequate space for cable management and ventilation.
- Mount the Power Strip: Use appropriate rack screws (not included) to securely fasten the power strip's mounting brackets to the rack rails.
- Podłącz do źródła zasilania: Plug the power strip's angled Schuko plug into a properly grounded wall outlet or UPS.
- Podłącz urządzenia: Plug your electrical devices into the 12 Schuko outlets on the power strip. Ensure the total power consumption does not exceed 3.5 kW.
Obraz: częściowy view of the power strip, highlighting the mounting brackets on the side, designed for vertical installation in a server rack.
Działanie
- Włączanie: Locate the thermal-magnetic circuit breaker on the power strip. Flip the switch to the "I ON" position to supply power to the outlets.
- Zabezpieczenie przed przeciążeniem: If the total current drawn by connected devices exceeds 16 A, the thermal-magnetic circuit breaker will automatically trip to the "O OFF" position, cutting power to prevent damage.
- Wyłączone: To cut power to all connected devices, flip the circuit breaker switch to the "O OFF" position.
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in a closed position, covering the blue switch.
Konserwacja
- Czyszczenie: Disconnect the power strip from the main power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- Kontrola: Periodically inspect the power strip, cable, and plug for any signs of wear, damage, or overheating. If any damage is observed, discontinue use immediately and replace the unit.
- Wentylacja: Ensure that the power strip and connected devices have adequate airflow to prevent overheating.
Rozwiązywanie problemów
| Problem | Możliwa przyczyna | Rozwiązanie |
|---|---|---|
| No power to outlets. | Zadziałał wyłącznik automatyczny. | Reduce the load by unplugging some devices, then reset the circuit breaker by flipping it to "I ON". |
| No power to outlets. | Listwa zasilająca nie jest podłączona. | Ensure the power strip's plug is securely inserted into a live wall outlet. |
| Devices not functioning. | Device-specific issue. | Check the individual device's power connection and functionality. |
Jeśli po wypróbowaniu tych rozwiązań problem nadal występuje, skontaktuj się z obsługą klienta.
Specyfikacje
- Model: I-CASE STRIP-12SH
- Marka: Techly Professional
- Punkty sprzedaży: 12 x Schuko (Type F) 45° angled with earth
- Wtyczka wejściowa: Angled Schuko (Type F)
- Kabel: H05VV-F 3G 2.5 mm²
- Długość kabla: 3 metrów
- Ocena elektryczna: 16A, 250VAC
- Maksymalna ładowność: 3.5 kW
- Wymiary (dł. x szer. x wys.): 735 x 62 x 44 mm (73.5L x 6.2W cm)
- Waga: 1795 gram
- Tworzywo: Aluminum (body), Black (finish)
- Dodatek specjalny: Mountable (vertical rack installation)
- Certyfikaty: CE, WEEE
Informacje o gwarancji
Information regarding specific warranty terms is not available in the provided product details. Please refer to the retailer's return policy or contact Techly Professional directly for warranty details.
Zasady zwrotu: The buybox winner indicates a 30-day return policy (refund/replacement).
Obsługa klienta
For technical assistance or further inquiries, please visit the official Techly webstronie internetowej lub skontaktuj się ze sprzedawcą.
Producent: TECHLY PROFESSIONAL
Webstrona: www.techly.com (Hypothetical link, as not provided in JSON)