Danfoss 067B2792

Danfoss TE5 N 4 Orifice Expansion Valve Instruction Manual

Model: 067B2792

1. Wprowadzenie

This manual provides essential information for the proper installation, operation, and maintenance of the Danfoss TE5 N 4 Orifice Expansion Valve, model 067B2792. This component is designed for use in refrigeration and air conditioning systems to regulate the flow of refrigerant.

2. Informacje dotyczące bezpieczeństwa

WARNING: Improper installation, operation, or maintenance can result in property damage, personal injury, or death. Only qualified personnel should perform work on refrigeration and air conditioning systems.

  • Zawsze należy nosić odpowiedni sprzęt ochrony osobistej (PPE), w tym okulary ochronne i rękawice.
  • Ensure the system is depressurized and isolated before attempting any installation or service.
  • Należy obchodzić się z czynnikami chłodniczymi ostrożnie i zgodnie z lokalnymi przepisami.
  • Refer to the overall system manufacturer's instructions for specific safety procedures.

3. Koniec produktuview

The Danfoss TE5 N 4 Orifice is a critical component of a thermostatic expansion valve (TXV) assembly. It is responsible for metering the flow of liquid refrigerant into the evaporator, thereby controlling the superheat at the evaporator outlet. The 'N 4' designation refers to the specific orifice size, which determines the capacity of the valve.

Danfoss TE5 N 4 Orifice Expansion Valve

Rysunek 1: Zbliżenie view of the Danfoss TE5 N 4 Orifice Expansion Valve assembly, showing the spring, internal components, and brass housing.

Strona view of Danfoss TE5 N 4 Orifice

Rysunek 2: Strona view of the Danfoss TE5 N 4 Orifice, highlighting its cylindrical shape and internal mechanism.

4. Konfiguracja i instalacja

The orifice is an interchangeable part within a compatible Danfoss TE5 thermostatic expansion valve body. Installation requires careful handling and adherence to manufacturer specifications.

4.1 Wymagane narzędzia

  • Appropriate wrench or specialized Danfoss tool for TXV orifice replacement.
  • Clean lint-free cloths.
  • Refrigerant-compatible lubricant (if specified by TXV body manufacturer).
Installation tool and washers for Danfoss TE5 orifice

Rysunek 3: Example of an installation tool and sealing washers, which may be required for orifice replacement.

4.2 Kroki instalacji

  1. Rozhermetyzuj układ: Ensure the refrigeration system is completely depressurized and isolated from refrigerant supply.
  2. Access TXV Body: Locate the thermostatic expansion valve body where the orifice is to be installed or replaced.
  3. Remove Old Orifice (if applicable): Carefully unscrew or unclip the existing orifice from the valve body using the appropriate tool. Note the orientation for correct installation of the new orifice.
  4. Kontrola i czyszczenie: Inspect the valve body for any debris or damage. Clean the seating area thoroughly with a lint-free cloth.
  5. Install New Orifice: Insert the new Danfoss TE5 N 4 Orifice into the valve body, ensuring correct orientation. Use the specialized tool to secure it firmly but do not overtighten. Ensure any necessary sealing washers are correctly seated.
  6. Test szczelności: After reassembling the TXV and system, perform a thorough leak test using an appropriate leak detection method.
  7. Evacuate and Charge: Evacuate the system to the required vacuum level and recharge with the correct type and amount of refrigerant according to system manufacturer specifications.
Danfoss TE5 N 4 Orifice with installation tool and washers

Figure 4: The Danfoss TE5 N 4 Orifice shown alongside an installation tool and sealing washers, illustrating components involved in the replacement process.

5. Instrukcja obsługi

The Danfoss TE5 N 4 Orifice operates passively within the thermostatic expansion valve. Its function is to provide a fixed restriction for refrigerant flow. The overall TXV, which houses this orifice, dynamically adjusts the refrigerant flow based on the superheat detected at the evaporator outlet. There are no user-adjustable settings on the orifice itself.

  • Ensure the system is charged with the correct refrigerant type and quantity.
  • Monitor system pressures and temperatures to confirm proper operation of the TXV and overall refrigeration cycle.

6. Konserwacja

The Danfoss TE5 N 4 Orifice itself is a static component and typically does not require routine maintenance. However, the overall thermostatic expansion valve and the refrigeration system should be regularly inspected by a qualified technician.

  • Roczna inspekcja: Have the refrigeration system, including the TXV, inspected annually for proper operation, leaks, and efficiency.
  • Czystość: Ensure the system remains free of contaminants, which can clog the orifice or other valve components.
  • Wymiana: If the system exhibits symptoms of an incorrect orifice size or a clogged orifice, replacement by a qualified technician may be necessary.

7. Rozwiązywanie Problemów

Issues related to the orifice are typically manifested as problems with the overall thermostatic expansion valve or system performance. Consult a qualified HVAC/R technician for diagnosis and repair.

Common Symptoms of Orifice-Related Issues:

  • High Superheat / Low Suction Pressure: May indicate a clogged or undersized orifice, restricting refrigerant flow.
  • Low Superheat / High Suction Pressure (with liquid floodback): May indicate an oversized orifice or a TXV stuck open, allowing too much refrigerant flow.
  • Fluctuating Suction Pressure: Could be due to intermittent clogging or improper TXV operation.

Notatka: These symptoms can also be caused by other system issues (e.g., refrigerant charge, compressor problems, evaporator coil issues). A comprehensive system diagnosis is essential.

8. Specyfikacje

SpecyfikacjaSzczegół
Numer modelu067B2792
Rozmiar otworuN 4 (Specific capacity for TE5 valves)
TworzywoStainless Steel (as per product specifications)
Waga przedmiotu3.68 uncji (w przybliżeniu)
Wymiary produktu5 x 1.87 x 1.87 cala (w przybliżeniu)
UPC-EAN5702428320993

9. Gwarancja i wsparcie

For warranty information regarding the Danfoss TE5 N 4 Orifice, please refer to the official Danfoss warranty policy or contact your authorized Danfoss distributor or seller. Warranty terms typically cover manufacturing defects under normal use conditions.

For technical support or further inquiries, please visit the official Danfoss webodwiedź stronę internetową lub skontaktuj się z działem obsługi klienta. Możesz również odwiedzić Danfoss Store on Amazon aby uzyskać dodatkowe informacje o produkcie.

Powiązane dokumenty - 067B2792

Przedview Instrukcja montażu elektrycznego zaworu rozprężnego Danfoss serii ETS
Instrukcja instalacji elektrycznych zaworów rozprężnych Danfoss (ETS 175L, ETS 250L, ETS 400L, ETS 500L) obejmująca specyfikacje techniczne, montaż, lutowanie, połączenia elektryczne, demontaż, montaż i ostrzeżenia dotyczące bezpieczeństwa.
Przedview Instrukcja montażu termostatycznego zaworu rozprężnego Danfoss TR6
Instrukcja instalacji termostatycznego zaworu rozprężnego Danfoss TR6, obejmująca informacje na temat zgodności czynnika chłodniczego, ciśnienia roboczego, kierunku przepływu, ustawień i specyfikacji technicznych.
Przedview Zawory rozprężne termostatyczne Danfoss TE 5, TE 12, TE 20, TE 55: instrukcje i specyfikacje
Niniejszy dokument zawiera instrukcje instalacji i specyfikacje techniczne termostatycznych zaworów rozprężnych Danfoss TE 5, TE 12, TE 20 i TE 55. Zawiera szczegółowe informacje na temat komponentów zaworów, procedur instalacji, ustawień momentu obrotowego, obliczeń przegrzania oraz tabele wydajności dla różnych czynników chłodniczych.
Przedview Dane techniczne i instrukcja zastosowania termostatycznego zaworu rozprężnego Danfoss TR6
Kompleksowy przewodnik po termostatycznym zaworze rozprężnym Danfoss TR6, obejmujący jego funkcje, zastosowania w systemach HVAC/R, specyfikacje techniczne, dobór rozmiarów, informacje o zamawianiu oraz zasady projektowania. Zawiera schematy i tabele ułatwiające korzystanie z niego.
Przedview Danfoss AKV 10P/10PS Electric Expansion Valve Spare Parts Service Guide
Comprehensive service guide for Danfoss AKV 10P and AKV 10PS electric expansion valves, detailing spare parts like orifice kits, filter kits, and armature kits, along with mounting and dismounting instructions.
Przedview Zawory rozprężne Danfoss Colibri® z napędem elektrycznym serii ETS – karta katalogowa
Kompleksowa karta danych technicznych elektrycznych zaworów rozprężnych Danfoss Colibri® zawierająca informacje na temat funkcji, konstrukcji, specyfikacji, zastosowań, informacji dotyczących zamawiania i rozwiązywania problemów dla modeli ETS 12C, ETS 24C, ETS 25C, ETS 50C i ETS 100C.