The AC Infinity AIRCOM S6 is a quiet cooling blower fan system specifically designed to cool various audio-video (AV) components such as receivers, amplifiers, DVRs, and game consoles. It helps prevent overheating, which can lead to performance issues and shorten the lifespan of your valuable electronics. This system features intelligent programming with thermal trigger modes and multiple speed control options to maintain optimal operating temperatures.

AC Infinity AIRCOM S6 front view

Rycina 1: Przód view of the AC Infinity AIRCOM S6 cooling system.

2. Konfiguracja i instalacja

The AIRCOM S6 is designed for easy integration into your AV setup. It features a rear-exhaust design, making it ideal for cabinets or racks where heat needs to be expelled from the back.

Umieszczenie:

  • Place the AIRCOM S6 directly on top of the AV component you wish to cool. Ensure the component's top surface is clear for optimal airflow.
  • For best results, ensure there is adequate space behind the unit for the rear exhaust to dissipate heat effectively.
  • Niskoprofile design allows other components to be stacked on top of the AIRCOM S6 if needed, provided proper ventilation is maintained.
AC Infinity AIRCOM S6 placed on an AV receiver in a cabinet

Figure 2: The AIRCOM S6 positioned on top of an AV receiver within a cabinet.

Diagram showing airflow from the AC Infinity AIRCOM S6

Figure 3: Illustration of the cooling airflow provided by the AIRCOM S6.

Podłączenie zasilania:

Connect the power adapter to the unit and plug it into a standard electrical outlet. The unit is ready for operation once powered.

3. Obsługa i sterowanie

The AIRCOM S6 features intuitive controls for managing its cooling performance. It includes programming features such as thermal trigger modes and four speed control options.

Close-up of AC Infinity AIRCOM S6 control panel with buttons and indicators

Figure 4: Control panel detailing programming options and speed settings.

Tryby sterowania:

  • Thermal Trigger Modes: The system can be set to automatically activate based on detected temperature, ensuring cooling only when necessary.
  • Kontrola prędkości: Choose from four fan speeds, ranging from silent to powerful, to balance cooling performance with noise levels. The dual-ball bearing blowers with PWM-controlled motors are designed to minimize operational noise.
  • Moctage Pamięć: The unit retains its last settings in case of a power interruption.

4. Konserwacja

To ensure the longevity and optimal performance of your AC Infinity AIRCOM S6, follow these simple maintenance guidelines:

  • Czyszczenie: Periodically clean the fan grilles and surfaces with a soft, dry cloth to prevent dust buildup, which can impede airflow and reduce cooling efficiency.
  • Wentylacja: Ensure that the rear exhaust area remains unobstructed to allow for proper heat dissipation.
  • Kontrola: Regularnie sprawdzaj, czy kabel zasilający nie nosi śladów uszkodzeń.

5. Rozwiązywanie Problemów

If you encounter any issues with your AIRCOM S6, consider the following common troubleshooting steps:

  • Urządzenie nie włącza się: Verify that the power adapter is securely plugged into both the unit and a working electrical outlet.
  • Niewystarczające chłodzenie: Check for any obstructions around the fan grilles or the rear exhaust. Ensure the unit is placed directly on the component requiring cooling.
  • Nietypowy hałas: Ensure the unit is placed on a stable, flat surface. Check for any foreign objects that might have entered the fan area.
  • Temperature Readings Inaccurate: Ensure the thermal probe (if applicable to your model) is correctly positioned to measure the component's temperature.

Jeśli po wykonaniu tych czynności problem nadal występuje, zapoznaj się z sekcją pomocy, aby uzyskać dalszą pomoc.

6. Specyfikacje techniczne

Detailed specifications for the AC Infinity AIRCOM S6:

Diagram showing dimensions and key specifications of AC Infinity AIRCOM S6

Figure 5: Dimensions and key specifications of the AIRCOM S6.

FunkcjaSzczegół
ModelAIRCOM S6 (AI-ACS6)
Wymiary produktu11.6" dł. x 6.3" szer. x 1.5" wys. (29.5 x 16.0 x 3.8 cm)
Waga3 funtów
Kierunek wydechuTył
Przepływ powietrza100 stopy sześcienne na minutę
Poziom hałasu20 dBA
Typ wentylatoraDual 120mm Dual-Ball Bearing Blowers
Pobór mocy5.2 watów
Tomtage240 wolty
Maksymalna prędkość obrotowa4200 obr./min.
TworzywoStal stopowa

7. Gwarancja i wsparcie

AC Infinity products are designed for reliability and performance. For specific warranty information, please refer to the documentation included with your purchase or visit the official AC Infinity webstrona.

For additional support, frequently asked questions, or to download the full user guide, please visit the AC Infinity support page or contact their customer service directly.

Możesz również uzyskać dostęp do oficjalnego podręcznika użytkownika w formacie PDF Tutaj.

Powiązane dokumenty - AI-ACS6

Przedview Instrukcja obsługi systemu chłodzenia komponentów AC Infinity serii AIRCOM
Instrukcja obsługi systemów chłodzenia AC Infinity serii AIRCOM, zawierająca szczegółowe informacje o funkcjach produktu, wymaganiach, konfiguracji, programowaniu, często zadawanych pytaniach i gwarancji. Zawiera numery modeli i specyfikacje serii AIRCOM S i T.
Przedview Instrukcja obsługi systemu chłodzenia komponentów AC Infinity serii AIRCOM
User manual for the AC Infinity AIRCOM Series Component Cooling System. Learn about product requirements, key features, setup, programming, and troubleshooting for models like AIRCOM S6, S7, S8, S9, S10, T8, T9, and T10. Includes warranty information and contact details.
Przedview Instrukcja obsługi systemu chłodzenia komponentów AC Infinity serii AIRCOM
User manual for the AC Infinity AIRCOM Series component cooling systems, detailing product requirements, features, setup, programming, other products, and warranty information.
Przedview AC Infinity Axial Series Project Cooling Fans User Manual
User manual for AC Infinity Axial Series Project Cooling Fans, detailing product specifications, key features, contents, fan replacement, mounting, powering, speed controller operation, other AC Infinity products, and warranty information.
Przedview AC Infinity Axial Series Project Cooling Fans User Manual
Comprehensive user manual for AC Infinity Axial Series project cooling fans. Covers product specifications, key features, contents, fan replacement, mounting, powering, speed controller operation, other AC Infinity products, and warranty information.
Przedview Instrukcja obsługi systemu chłodzenia szafy AC Infinity AIRPLATE Series
Instrukcja obsługi systemu chłodzenia szaf AC Infinity AIRPLATE Series zawierająca szczegółowe informacje na temat funkcji produktu, instalacji, zasilania, programowania sterownika dla modeli T-Series i Multizone, odpowiedzi na często zadawane pytania oraz informacje dotyczące gwarancji.