Everbilt DP370C

EVERBILT 3/4 HP Convertible Jet Pump with Ejecter

Model: DP370C | Brand: Everbilt

1. Koniec produktuview

The Everbilt 3/4 HP Convertible Jet Pump with Ejecter, Model DP370C, is designed for reliable water supply in both shallow and deep well applications. Constructed from rugged cast iron, this pump is built for durability and long-lasting performance. It comes supplied with a shallow well ejector installed, and includes components for deep well conversion, making it versatile for various water source depths.

Key features include a heavy-duty dual-voltage 115/230-Volt motor, pre-set at 230-Volt for immediate use in higher voltage systems. It is capable of handling shallow well water levels up to 25 feet and deep well water levels up to 70 feet.

Everbilt 3/4 HP Convertible Jet Pump, main view

Rysunek 1.1: Główny view of the Everbilt 3/4 HP Convertible Jet Pump (DP370C). This image shows the robust cast iron body, the motor housing, and the integrated pressure gauge, highlighting its compact and durable design.

2. Informacje dotyczące bezpieczeństwa

WARNING: Read and understand all safety warnings and instructions before installing or operating this pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.

  • Always disconnect power to the pump before performing any maintenance or service.
  • Ensure proper grounding to prevent electrical shock. All wiring must comply with local electrical codes.
  • Do not operate the pump in an explosive atmosphere, such as in the presence of flammable liquids, gases, or dust.
  • Protect the pump from freezing temperatures. Freezing can cause severe damage and void the warranty.
  • This pump is designed for pumping clean water only. Do not use it for pumping corrosive, abrasive, or flammable liquids.
  • The motor is pre-set at 230-Volt. Verify your power supply matches the pump's voltage setting before connection.

3. Komponenty i funkcje

The DP370C pump includes several key components for its operation and versatility:

  • Cast Iron Body: Provides robust and durable housing for the pump's internal components.
  • Silnik 3/4 KM: A powerful, heavy-duty motor capable of operating on dual voltage (115V/230V), factory pre-set to 230V.
  • Shallow Well Ejector: Pre-installed for immediate use in shallow well applications.
  • Deep Well Components: Included for converting the pump to deep well operation, allowing for water extraction from greater depths.
  • Ciśnieniomierz: Integrated to monitor system pressure.
  • Wyłącznik ciśnieniowy: Automatically controls pump operation based on system pressure (not explicitly mentioned but implied for automatic operation).
Close-up of Everbilt Jet Pump motor and gauge

Rysunek 3.1: Zbliżenie view of the Everbilt pump's motor and pressure gauge. The yellow label indicates the factory preset voltage of 230V, and the gauge provides real-time pressure readings.

Strona view of Everbilt Jet Pump showing inlet and outlet

Rysunek 3.2: Strona view of the Everbilt pump, illustrating the various connection points for water inlet and outlet pipes. This view also shows the robust construction and the location of the ejector assembly.

4. Konfiguracja i instalacja

4.1. Lista kontrolna przed instalacją

  • Sprawdź napięcie zasilaniatage (115V or 230V) matches pump setting. The pump is factory pre-set to 230V. If 115V is required, consult the wiring diagram for conversion.
  • Ensure adequate space for pump installation, allowing for ventilation and access for maintenance.
  • Gather necessary plumbing fittings, pipes, and electrical supplies.
  • Confirm the well depth is within the pump's operating range (25 ft for shallow, 70 ft for deep).

4.2. Połączenia hydrauliczne

  1. Connect the suction line from the well to the pump's inlet. Ensure all connections are airtight to prevent air leaks, which can cause the pump to lose prime.
  2. Connect the discharge line from the pump's outlet to your water distribution system.
  3. If converting to deep well operation, install the deep well ejector kit according to the provided instructions, connecting the pressure and suction lines to the well.
  4. Aby zapewnić zasysanie, zamontuj zawór zwrotny na linii ssącej.

4.3. Połączenia elektryczne

  1. Ensure the main power supply is OFF at the circuit breaker before making any electrical connections.
  2. Podłącz pompę do dedykowanego obwodu elektrycznego z odpowiednim zabezpieczeniem nadprądowym.
  3. Wire the pump according to the wiring diagram located on the motor housing or in the included manual, ensuring proper grounding.
  4. Potwierdź objętośćtage setting (115V or 230V) matches your power supply. The pump is pre-set to 230V.

4.4. Zalewanie pompy

  1. Remove the priming plug located on the top of the pump casing.
  2. Napełnij pompę casindokładnie opróżnij czystą wodą, aż się przeleje.
  3. Dokładnie zakręć korek zalewowy.
  4. Turn on the power supply to the pump. The pump should begin to draw water and build pressure. If it does not prime within 5 minutes, turn off the power, re-prime, and check for air leaks in the suction line.

5. Instrukcja obsługi

5.1. Pierwsze uruchomienie

After successful installation and priming, turn on the power to the pump. The pressure switch will engage the pump when system pressure drops below a pre-set level and turn it off when the desired pressure is reached. Monitor the pressure gauge to ensure proper operation.

5.2. Normalna praca

The pump is designed for automatic operation. It will cycle on and off as water is demanded by your system. Ensure that the pump is not running dry, as this can cause severe damage. If the pump runs continuously without building pressure, refer to the troubleshooting section.

5.3. Wyłączanie pompy

For temporary shutdown, simply turn off the power supply to the pump at the circuit breaker. For extended periods of non-use, especially in freezing conditions, follow the winterization procedures in the maintenance section.

6. Konserwacja

Regular maintenance ensures the longevity and efficient operation of your Everbilt jet pump.

6.1. Rutynowe kontrole

  • Miesięczny: Inspect all plumbing connections for leaks. Check the pressure gauge for consistent readings. Listen for unusual noises from the pump motor.
  • Rocznie: Inspect the pump for any signs of corrosion or wear. Check electrical connections for tightness and signs of overheating.

6.2. Zimowanie (w zimnym klimacie)

If the pump is installed in an area subject to freezing temperatures and will not be used during winter, it must be drained to prevent damage:

  1. Odłączyć zasilanie pompy.
  2. Open all drain plugs on the pump casing and piping.
  3. Allow all water to drain completely. You may need to tilt the pump slightly to ensure full drainage.
  4. Store the pump in a dry, frost-free location if possible, or ensure all water is removed from the system.
  5. Once drained, replace the drain plugs loosely to allow for air circulation, or remove them and store them safely until spring.

6.3. Czyszczenie

Keep the exterior of the pump clean and free from debris. Do not use harsh chemicals or abrasive cleaners. Ensure ventilation openings on the motor are clear.

7. Rozwiązywanie Problemów

This section provides solutions to common issues you might encounter with your Everbilt jet pump.

ProblemMożliwa przyczynaRozwiązanie
Pump runs but no water or low pressure.
  • Utrata prymatu.
  • Wyciek powietrza w przewodzie ssawnym.
  • Low water level in well.
  • Clogged impeller or piping.
  • Ponownie zalać pompę.
  • Sprawdź szczelność wszystkich połączeń przewodu ssącego.
  • Verify well water level.
  • Sprawdź i usuń wszelkie przeszkody.
Pompa nie uruchamia się.
  • Brak prądu do pompowania.
  • Zadziałał wyłącznik automatyczny.
  • Wadliwy przełącznik ciśnienia.
  • Motor overload protector tripped.
  • Sprawdź zasilanie.
  • Zresetuj wyłącznik obwodu.
  • Inspect/replace pressure switch.
  • Allow motor to cool, then reset.
Pompa pracuje zbyt często.
  • Leaking plumbing fixture.
  • Zalany wodą zbiornik ciśnieniowy.
  • Pressure switch differential too small.
  • Check for and repair leaks.
  • Recharge pressure tank air pre-charge.
  • Adjust pressure switch settings (consult a professional).

Jeśli po wypróbowaniu tych rozwiązań problem nadal występuje, skontaktuj się z wykwalifikowanym technikiem serwisowym.

8. Specyfikacje

AtrybutSzczegół
MarkaEverbilt
Numer modeluDP370C
Moc (KM)3 / 4 HP
Tomtage115V / 230V (Factory pre-set at 230V)
TworzywoLane żelazo
KolorCzarny
Płytka i dobra aplikacjaWater level up to 25 ft
Aplikacja do głębokich studniWater level up to 70 ft
Waga przedmiotu35.5 funtów
Wymiary produktu23 x 10 x 11 cala
Źródło zasilaniaElektryczny

9. Gwarancja i wsparcie

The Everbilt 3/4 HP Convertible Jet Pump, Model DP370C, typically comes with a 1-roczna ograniczona gwarancja from the date of purchase, as indicated on the product packaging. This warranty covers defects in materials and workmanship under normal use and service.

For warranty claims, technical support, or service inquiries, please contact Everbilt customer service. It is recommended to have your product model number (DP370C) and proof of purchase readily available when contacting support.

Note: This product may be refurbished. Refurbished products are tested and certified to look and work like new. The refurbishing process includes functionality testing, basic cleaning, inspection, and repackaging. The product ships with all relevant accessories, and may arrive in a generic box.

Powiązane dokumenty - DP370C

Przedview Instrukcja użytkowania i konserwacji pompy strumieniowej Everbilt Convertible
Kompleksowy przewodnik po pompie strumieniowej Everbilt Convertible Jet Pump, obejmujący instalację, obsługę, konserwację i rozwiązywanie problemów zarówno w przypadku studni płytkich, jak i głębokich. Zawiera środki ostrożności i specyfikacje wydajności.
Przedview Everbilt Convertible Jet Pump Use and Care Guide: DP370C & DP550C Models
Comprehensive use and care guide for Everbilt convertible jet pumps, models DP370C and DP550C. Includes installation instructions for shallow and deep wells, safety information, performance specifications, and troubleshooting tips.
Przedview Everbilt Convertible Jet Pump: Use and Care Guide, Installation, and Troubleshooting
Comprehensive guide for Everbilt Convertible Jet Pumps (Models DP370C, DP550C). Includes installation instructions for shallow and deep wells, safety information, performance specifications, warranty details, and troubleshooting tips.
Przedview EVERBILT 1 HP Professional Convertible Jet Pump (HDCWJ10) Operation Instructions
Comprehensive operation instructions for the EVERBILT 1 HP Professional Convertible Jet Pump (Model HDCWJ10). This guide covers essential safety precautions, installation steps for the pressure switch, voltage selection (115V/230V), and troubleshooting tips for shallow or deep well applications.
Przedview Everbilt 1 HP Professional Convertible Jet Pump Troubleshooting Guide HDCWJ10
Troubleshooting guide for the Everbilt 1 HP Professional Convertible Jet Pump (Model HDCWJ10) for shallow or deep well applications, covering common issues like humming, low flow, and pressure problems.
Przedview Instrukcja montażu akcesoriów hydroizolacyjnych Everbilt
Kompleksowy przewodnik montażu akcesoriów hydroizolacyjnych Everbilt, szczegółowo opisujący przygotowanie podłoża, wykonanie szwów, uszczelnianie narożników i rur oraz ostateczne nakładanie płytek w przypadku instalacji wodoodpornych.