This user manual provides essential information for the safe and effective operation of the Megger MIT400/2 Insulation & Continuity Tester, model 1006-719. This versatile instrument is designed for a wide range of applications, including electrical installations, cable testing, motor testing, automotive diagnostics, ESD measurements, panel building, avionics, and general maintenance.

The MIT400/2 features enhanced insulation testing with feedback-controlled test voltages, limiting over-voltage to 2%. It also offers a variable voltage range from 250 V to 1000 V in 10 V steps for specific application requirements. Continuity testing is significantly faster, with an autoranging function from 0.01 ̑ to 1.0 M̑, and retains 200 mA and 20 mA test options. The redesigned unit boasts an over-moulded case for increased protection and an IP54 weatherproof rating.

Informacje dotyczące bezpieczeństwa

Always adhere to local and national safety regulations when using electrical test equipment. Failure to follow these safety guidelines may result in injury, damage to the instrument, or damage to the equipment under test.

Produkt ponadview

Megger MIT400/2 Insulation and Continuity Tester front view

Rycina 1: Przód view of the Megger MIT400/2 Insulation & Continuity Tester, showing the display, control buttons, and rotary selector switch.

The Megger MIT400/2 features a clear digital display for readings and settings. Key controls include:

Organizować coś

Instalacja baterii

The MIT400/2 is powered by 6 AA batteries. The battery compartment is located at the rear of the unit and features separate fuse access.

  1. Ensure the instrument is switched to the OFF position.
  2. Znajdź pokrywę komory baterii z tyłu urządzenia.
  3. Unscrew or unlatch the cover and remove it.
  4. Insert 6 AA batteries, observing the correct polarity indicated inside the compartment.
  5. Załóż pokrywę komory baterii i mocno ją dokręć.

Kontrole wstępne

Before first use, or after battery replacement, perform a quick functional check to ensure the unit powers on and the display is clear.

Instrukcja obsługi

Insulation Testing (M̑)

The MIT400/2 offers insulation testing up to 1000 V and 200 G̑ range with stabilized test voltage.

  1. Turn the rotary selector switch to the desired M̑ voltage range (e.g., 250V, 500V, 1kV). A variable range allows intermediate voltages from 250 V to 1000 V in 10 V steps.
  2. Connect the test leads to the circuit or component under test, ensuring proper polarity.
  3. Press and hold the yellow TEST button to initiate the test. The display will show the insulation resistance.
  4. For continuous testing, press the red Zamek przycisk po naciśnięciu TEST. Naciskać TEST again to unlock.
  5. Uwolnij TEST przycisk, aby zatrzymać pomiar.

Continuity Testing (̑)

The instrument provides fast autoranging continuity testing from 0.01 ̑ to 1.0 M̑, with 200 mA and 20 mA test options.

  1. Turn the rotary selector switch to the ̑ position.
  2. Podłącz przewody pomiarowe do obwodu lub elementu.
  3. The instrument will automatically display the resistance. If continuity is detected within the set threshold, an audible beep may sound (if enabled).
  4. Użyj Dźwięk button to toggle the continuity beeper.

Tomtage Pomiar (V)

Measure AC or DC voltage.

  1. Turn the rotary selector switch to the V position.
  2. Connect the test leads across the voltagŹródło.
  3. The display will show the measured voltage.
  4. Naciśnij TRMS button to toggle between True RMS and average sensing for AC voltagpomiary.

Podświetlenie wyświetlacza

Naciśnij Podświetlenie button to illuminate the display for better readability in dimly lit environments. Press again to turn off.

Konserwacja

Czyszczenie

Regularnie czyść instrument za pomocąamp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the unit is dry before storage or use.

Wymiana baterii

When the low battery indicator appears on the display, replace all 6 AA batteries as described in the "Battery Installation" section. Always use fresh, high-quality batteries.

Dostęp do bezpiecznika

The MIT400/2 features separate fuse access within the battery compartment. Refer to the full service manual for fuse specifications and replacement procedures.

Kalibrowanie

Your Megger MIT400/2 is calibrated prior to shipment and comes with a new NIST-traceable calibration certificate with data. This ensures the instrument meets manufacturer's specifications and is ready for use, meeting most quality system standards. Regular calibration by qualified personnel is recommended to maintain accuracy.

Rozwiązywanie problemów

For more complex issues, contact Megger customer support or a qualified service technician.

Specyfikacje

FunkcjaSpecyfikacja
Numer modelu1006-719
Test izolacji, tomtageUp to 1000 V (variable from 250 V in 10 V steps)
Zakres rezystancji izolacjiUp to 200 G̑
Zakres ciągłości0.01 ̑ to 1.0 M̑ (autoranging)
Prąd testu ciągłości200 mA and 20 mA options
Źródło zasilania6 baterie AA
Ocena odporności na warunki atmosferyczneIP54
Wymiary (w przybliżeniu)12.4 x 10.98 x 4.25 cala
Waga (w przybliżeniu)3 funtów
KolorBlack, Gray, Red

Gwarancja i wsparcie

For information regarding product warranty, technical support, or service, please contact Megger directly. Refer to the official Megger website or your purchase documentation for contact details and warranty terms specific to your region.

Producent: Megger

Powiązane dokumenty - 1006-719

Przedview Testery izolacji Megger MIT400/2 CAT IV: funkcje, specyfikacje i zastosowania
Kompleksowa karta katalogowa testerów izolacji i ciągłości obwodu Megger serii MIT400/2 CAT IV. Szczegółowe informacje na temat funkcji, specyfikacji, zastosowań, bezpieczeństwa oraz porównania modeli do testów elektrycznych i przemysłowych.
Przedview Wielofunkcyjny tester Megger MFT-X1: funkcje, specyfikacje i zastosowania
Kompleksowy ponadview testera wielofunkcyjnego Megger MFT-X1, szczegółowo opisując jego zaawansowane funkcje, takie jak testowanie True Loop™, Confidence Meter™, zgodność z CertSuite i rozbudowane możliwości testowania elektrycznego w zakresie niskich wartościtage instalacje.
Przedview Wielofunkcyjny tester Megger MFT1741: funkcje, specyfikacje i zastosowania
Kompleksowy ponadview Opis testera wielofunkcyjnego Megger MFT1741, szczegółowo opisujący jego zaawansowane funkcje, takie jak pomiar impedancji pętli zwarcia bez zadziałania zabezpieczenia, analiza „miernika ufności” oraz rozbudowane możliwości testowania wyłączników różnicowoprądowych RCD w instalacjach elektrycznych w przemyśle, handlu i domach. Zawiera pełną specyfikację i informacje dotyczące zamówień.
Przedview Testery rezystancji izolacji Megger ADVANCED o zakresie 5 kV, 10 kV, 15 kV
Poznaj solidną i niezawodną serię testerów rezystancji izolacji Megger ADVANCED o napięciu 5 kV, 10 kV i 15 kV. Odkryj zaawansowane funkcje, takie jak tryb RE>Act dla większej dokładności, predyktor PI dla szybszego testowania oraz wysoka zmienność.tagZakres pomiaru do 30 TΩ. Zaprojektowane do zastosowań przemysłowych, te testery oferują najwyższy poziom bezpieczeństwa (klasa CAT IV) i intuicyjną obsługę, co pozwala na wydajną konserwację i testowanie instalacji elektrycznych.
Przedview Megger MIT485/2TC Szybki przewodnik: tomtage, ciągłość i testowanie rezystancji izolacji
Krótki przewodnik szybkiego startu dla testera elektrycznego Megger MIT485/2TC, szczegółowo opisujący procedury pomiaru napięciatage (AC/DC), ciągłość i rezystancja izolacji z czytelnymi schematami połączeń i podsumowaniami warunków testowych.
Przedview Megger S1-568/2, S1-1068/2, S1-1568/2: Instrukcja obsługi wysokowydajnych testerów rezystancji izolacji prądu stałego
Kompleksowy podręcznik użytkownika wysokowydajnych testerów rezystancji izolacji prądu stałego Megger S1-568/2, S1-1068/2 i S1-1568/2. Obejmuje funkcje, obsługę, bezpieczeństwo i specyfikacje techniczne dotyczące przemysłowych testów elektrycznych.