Zurn P1000AXL-150C

Zurn RV 150 PSI CA# FWL-2 Water Equipment User Manual

Model: P1000AXL-150C

1. Wprowadzenie i koniecview

This manual provides essential instructions for the safe and effective installation, operation, and maintenance of the Zurn RV 150 PSI CA# FWL-2 Water Equipment. This device is designed to prevent over-pressure in storage tanks, ensuring system integrity and safety. Please read this manual thoroughly before installation or use.

Zurn RV 150 PSI CA# FWL-2 Water Equipment

Rysunek 1: Zurn RV 150 PSI CA# FWL-2 Water Equipment. This image shows the brass pressure relief valve with a male NPT inlet and a female NPT outlet, along with the pressure setting mechanism on top.

2. Informacje dotyczące bezpieczeństwa

OSTRZEŻENIE: Improper installation or use of this device can lead to property damage, serious injury, or death. All installation and maintenance should be performed by a qualified professional in accordance with local codes and regulations.

3. Funkcje produktu

4. Co znajduje się w pudełku

Opakowanie produktu zazwyczaj zawiera:

Please inspect the contents upon receipt to ensure all components are present and undamaged.

5. Konfiguracja i instalacja

Installation should only be performed by a qualified plumber or technician. Adhere to all local plumbing codes and regulations.

  1. Dekompresja układu: Before beginning installation, ensure the water system is completely shut off and depressurized. Drain any residual water from the system.
  2. Wybór lokalizacji: Install the relief valve in an accessible location on the storage tank or water equipment, typically at the highest point or as specified by the tank manufacturer.
  3. Przygotowanie wątku: Apply appropriate thread sealant (e.g., PTFE tape or pipe dope) to the 3/4" male NPT inlet threads of the relief valve.
  4. Połączenie: Carefully thread the valve into the designated port on the storage tank. Tighten securely using a wrench, but do not overtighten, which can damage the valve or tank.
  5. Rurociągi wylotowe: Connect appropriate discharge piping to the 3/4" female NPT outlet. The discharge pipe must be sized correctly, sloped for drainage, and terminate in a safe location where discharged water will not cause damage or injury. Do not cap or restrict the discharge pipe.
  6. Ponowne sprężanie układu: Slowly repressurize the system and check for leaks at all connections.
  7. Kontrola funkcjonalności: Verify that the valve is not leaking and that the system pressure is within acceptable limits for the valve's setting.

6. Działanie

The Zurn RV 150 PSI CA# FWL-2 Water Equipment is an automatic pressure relief valve. It is designed to open and discharge water when the system pressure exceeds its factory-set limit (e.g., 150 PSI for this model). This action prevents excessive pressure buildup within the storage tank, protecting the tank and connected components from potential damage.

Under normal operating conditions, the valve remains closed. If the valve discharges water, it indicates an over-pressure condition in the system. Investigate the cause of the over-pressure immediately.

7. Konserwacja

Regular inspection and maintenance are crucial for the continued safe operation of the relief valve. It is recommended to have the valve inspected annually by a qualified professional.

8. Rozwiązywanie Problemów

ProblemMożliwa przyczynaRozwiązanie
Valve continuously drips or leaks.
  • Sediment or debris lodged in the valve seat.
  • Zużyte elementy wewnętrzne.
  • System pressure consistently too high.
  • Attempt manual test to flush debris.
  • Replace the valve if worn.
  • Check system pressure regulator or expansion tank.
Valve does not discharge during over-pressure.
  • Valve is seized or clogged.
  • Incorrect valve for application.
  • Attempt manual test. If still unresponsive, replace the valve immediately.
  • Verify valve specifications match system requirements.
Water discharges frequently.
  • System pressure fluctuations.
  • Expansion tank malfunction.
  • Valve set point too low for system.
  • Consult a professional to diagnose system pressure issues.
  • Inspect and service expansion tank.
  • Ensure correct valve is installed.

For persistent issues or if you are unsure about any troubleshooting steps, contact a qualified plumbing professional.

9. Specyfikacje

AtrybutSzczegół
MarkaZurn
Numer modeluP1000AXL-150C
Opis produktuRV 150 PSI CA# FWL-2 Lead Free Water Equipment
Rozmiar3/4 cala
Przyłącze wlotowe3/4" męski NPT
Podłączenie wyjściowe3/4" Female NPT
TworzywoMosiądz
KolorMosiądz
Wykończenie zewnętrzneMosiądz
Typ wątkuNPT
Waga przedmiotu0.5 funta (ok. 8 uncji)
Wymiary produktu (dł. x szer. x wys.)1.25 x 1.25 x 3.44 cala
CertyfikatyCSA Compliance to ANSI Z21.22/CSA 4.4, Certified to ASME Section IV by National Board

10. Gwarancja i wsparcie

For information regarding product warranty, technical support, or replacement parts, please contact Zurn customer service directly. You can find contact information and additional resources on the official Zurn webwitrynę lub odwiedzając Zurn Store on Amazon.

Powiązane dokumenty - P1000AXL-150C

Przedview Zespół zaworu redukcyjnego ciśnienia Zurn Wilkins ZW209FP: instalacja, obsługa i konserwacja
Kompleksowy przewodnik po zespole zaworu redukcyjnego ciśnienia przeciwpożarowego Zurn Wilkins ZW209FP, obejmujący instalację, uruchomienie, obsługę, charakterystykę przepływu i procedury konserwacyjne. Zawiera szczegółowe instrukcje dotyczące zaworu głównego i zaworu pilotowego PV-PRD.
Przedview Zawór redukcyjny ciśnienia Zurn NR3XL bez ołowiu: Instrukcja montażu, konserwacji i naprawy
Kompleksowy przewodnik po bezołowiowym zaworze redukcyjnym ciśnienia Zurn NR3XL, obejmujący instalację, kontrolę, konserwację, procedury naprawcze i rozwiązywanie problemów. Zawiera specyfikację produktu i informacje o gwarancji.
Przedview ZURN 600XL Lead-Free Pressure Reducing Valve Installation, Maintenance, and Repair Guide
Comprehensive guide for the ZURN 600XL Lead-Free Pressure Reducing Valve, covering installation, inspection, maintenance, repair, and troubleshooting. Includes specifications, warranty information, and part details.
Przedview Zurn NR3XL Water Pressure Reducing Valve with Integral By-Pass Check Valve and Strainer
Detailed specifications and installation guide for the Zurn NR3XL, a water pressure reducing valve designed for potable water lines. Features include an integral strainer, by-pass check valve, and low lead cast bronze body. Suitable for residential and commercial applications.
Przedview Zurn AquaSense ZER-SM Series Automatic Battery-Powered Flush Valve Manual
Comprehensive manual for Zurn AquaSense ZER-SM series automatic battery-powered flush valves, covering installation, operation, maintenance, troubleshooting, and parts breakdown for models like ZER6000-SM, ZER6200-SM, ZER6003-SM, and ZER6203-SM.
Przedview ZURN Model AG Air Gap Adaptor Fitting
The ZURN Model AG Air Gap Adaptor Fitting is designed for use with ZURN WILKINS Reduced Pressure Principle Backflow Preventers, ensuring proper drain line installation on horizontal or vertical systems. This document details its specifications, materials, and typical installation requirements.